Laserfiche WebLink
SPECIFICATIONS <br /> Heating Model No. GCS16-072 GCS16-090 GCS16-120 GCS16-150 <br /> Performance Input(low)-Btuh(kW)Natural Gas/LPG-Propane 105,000/101,000 131,000/126,000 177,000/170,000 177,0001170,000 <br /> (30.8/29.6) (38.3/36.9) (51.9149.8) (51.9/49.8) <br /> Input(High)-Btuh(kW)Natural Gas/LPG-Propane 160,000/140,000 200,000/175,000 270,0001236,000 270,000/236,000 <br /> (46.9/41.0) (58.6/51.3) (79.1/69.1) (79.1169.1) <br /> Output(High)-Btuh(kW)Natural Gas/LPG-Propane 128,000/114,000 160,0001142,600 216,0001192,000 216,000/192,000 <br /> (37.5/33.4) (46.9/41.8) (63.3/56.3) (63.3156.3) <br /> AGA/CGA Thermal Efficiency Natural Gas/LPG-Propane 80.0%/81.4% 80.0%181.0°/a 80.0%181.4% 80.0%181.4% <br /> Gas Supply Connections fpt-in.(mm) 3/4(19) 3/4(19) 314(19) 3/4(19) <br /> Recommended Gas Supply Pressure-we.in.(kPa)Natural 7(1.7) 7(1.7) 7(1.7) 7(1.7) <br /> LPG/Propane 11 (2.7) 11 (2.7) 11 (2.7) 11 (2.7) <br /> Cooling Nominal Tonnage(kW) 6(21.1) 7.5(26.4) 10(35.2) 12.5(42.2) <br /> Performance Gross cooling capacity-Btuh(kW) 74,800(21.9) 92,800(27.2) 123,000(36.0) 150,000(44.0) <br /> *Net cooling capacity-Btuh(kW) 72,000(21.1) 88,000(25.8) 117,000(34.3) 144,000(42.2) <br /> Total unit kW 8.0 9.8 13.0 16.0 <br /> *EER(BtuhM/atts) 9.0 9.0 9.0 9.0 <br /> *Integrated Part Load Value ---- 9.5 9.2 8.5 <br /> `Sound Rating Number(db) 86 86 82 88 <br /> Refrigerant Charge(HCFC-22)Circuit 1 9 lbs.8 oz. 6 lbs.0 oz. 7 lbs,8 oz. 8 lbs.8 oz. <br /> (4.31 kg) (2.72 kg) (3.4 kg) (3.9 kg) <br /> Circuit 2 ---- 6 lbs.0 oz. 7 lbs.8 oz. 8 lbs.8 oz. <br /> (2.72 kg) (3.4 kg) (3.9 kg) <br /> Condenser Net face area-sq.ft.(m2) 13.0(1.21) 15.67(1.46) 24.0(2.23) 24.0(2.23) <br /> Coil Tube diameter-in.(mm) 318(9.5) 3/8(9.5) 318(95) 3/8(9.5) <br /> No.of rows 2 2 2 2 <br /> Fns per inch(m) 20(787) 20(787) 20(787) 20(787) <br /> Condenser Motor horsepower(W) (1)1/3(249) (1)3/4(560) (2)113(249) (2)112(373) <br /> Fan(s) Motor rpm 1075 1075 1075 1075 <br /> Motor watts 450 650 650 1250 <br /> Diameter-in.(mm) (1)24(610) (1)24(610) (2)20(508) (2)24(610) <br /> No.of blades 3 4 4 3 <br /> Air volume-cfrn(Us) 4100(1935) 5150(2430) 6400(3020) 8400(3965) <br /> Evaporator Net face area-sq,ft,(m2) 7.75(0.72) 7.75(0.72) 9.46(0.88) 11.92(1.11) <br /> Coil Tube diameter-in.(mm) 318(9.5) 318(9,5) 3/8(9.5) 3/8(9.5) <br /> No.of rows 3 3 3 4 <br /> Fins per inch(m) 14(551) 14(551) 14(551) 14(551) <br /> Expansion device type Thermostatic E cpansion Valve <br /> Condensate drain size(furnished) 1 in.-11-112 r pt pipe nipple <br /> Evaporator Nominal motor hp(kW) 2(1.5) 2(11.5) 3(2.2) 3(2.2) <br /> Blower Maximum usable hp(kW) 2.30(1.7) 2.30(1.7) 3.45(2.6) 3.45(2.6) <br /> RPM range 845-1130 845-1130 735-1015 735-1015 <br /> Slower wheel nominal diameter x width-in.(mm) 12 x 12 12 x 12 15 x 15 15 x 15 <br /> (305 x 305) (305 x 305) (381 x 381) (381 x 381) <br /> Filters Filter type Disposab e,MERV 7 rated,commercial grade, pleated <br /> (furnished) No.&size-in.(mm) (4)16 x 20 x 2 4)16 x 20 x 2 (2)16 x 25 x 2 (2)20 x 25 x 2 <br /> (406 x 50B x 51) (446 x 508 x 51) (406 x 635 x 51) (508 x 635 x 51) <br /> (2)16x20 x2 (2)20x20x2 <br /> (406 x 508 x 51) (508 x 508 x51) <br /> Shipping Net weight of basic unit-lbs.(kg) 760(345) 875(397) 1100(499) 1200(544) <br /> Data Shipping weight of basic unit-lbs.(kg)(1 Pkg.) 900(408) 1060(481) 1 1285(582) 1 1385(628) <br /> Electrical characteristics 208/230v,460v or 575v-60 hertz-3 phase <br /> `Sound Rating Number in accordance with test conditions included in ARI Standard 270. <br /> *Certified in accordance with the ULE certification program,which is based on ARI Standard 3401360;95°F(35°C)outdoor air temperature and 80°F(27°C)db/67°F(19°C) <br /> wb entering evaporator air;minimum external duct static pressure.Integrated Part Load Value tested at 80°F(27°C)outdoor air temperature. <br /> NOTE-ARI capacity is net and includes evaporator blower motor heat deduction.Gross capacity does not include evaporator blower motor heat deduction. <br /> NOTE-Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required.Maximum usable output of <br /> motors furnished by Lennox are shown.In Canada,nominal motor output is a[=maximum usable motor output.If motors of comparable output are used,be sure to keep within <br /> the service factor limitations outlined on the motor nameplate. <br /> r-r•carz_m9-nan-4,?n-inn/PnnA A► <br />