My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL DATA 072-090 MODELS <br /> General Model No. GCS16-072 GCS16-090 <br /> Data <br /> Line voltage data-60 Hz-3 phase 208/230v 460v 575v 208/230v 460v 575v <br /> Recommended maximum fuse size(amps) 50 25 20 50 25 20 <br /> tMinimum Circuit Ampacity 34 17 14 42 21 17 <br /> Compressors(s) No.of compressors 1 1 1 2 2 2 <br /> Rated load amps-each(total) 18.8 9.1 7.5 13.3(26.6) 6.7(13.4) 5.4(10.8) <br /> Locked rotor amps-each(total) 156 75 54 91 (182) 46(92) 37(74) <br /> Condenser Full load amps 2.4 1.3 1.0 3.7 1.9 1.6 <br /> Fan Motor' <br /> Locked rotor amps 4.7 2.4 1.9 7.3 3.7 2.9 <br /> Evaporator Motor Output-hp(kW) 2(1.5) 2(1.5) 2(1,5) 20-5) 2(1.5) 2(1.5) <br /> Blower <br /> Motor Full load amps 7.5 3.4 2.7 7.5 3.4 2.7 <br /> Locked rotor amps 41 20.4 16.2 41.0 20.4 16.2 <br /> tRefer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. <br /> pwhere current does not exceed 100 amps,HACK type circuit breaker may be used in place of fuse(U.S.only). <br /> NOTE-Extremes of operating range are plus and minus 10%of line voltage. <br /> ELECTRICAL1 120-150 MODELS <br /> General Model No. GCS16-120 GCS16-150 <br /> Data <br /> Line voltage data-64 Hz-3 phase 208/230v 460v 575v 208/230v 460v 575v <br /> Recommended maximum fuse size(amps) 70 35 25 70 35 30 <br /> tMinimunn Circuit Ampacity 58 28 21 59 29 24 <br /> Compressors(2) Rated load amps-each(total) 18.6(37.2) 10(20) 6.6(13.2) 18.8(37.6) 9.1 (18.2) 7.5(15) <br /> Locked rotor amps-each(total) 128(256) 63(126) 49(98) 156 (312) 75(150) 54(108) <br /> Condenser Full load amps (2)4.8 (2)2.6 (2)2.0 (2)6.0 (2)3.0 (2)2.4 <br /> Fan Motors <br /> Locked rotor amps (2)9.4 (2)4.8 (2)3.8 (2)12.0 (2)6.0 (2)5.8 <br /> Evaporator Motor Output-hp(kW) 3(2.2) 3(2.2) 3(2.2) 3(2.2) 3(2.2) 3(2.2) <br /> Blower <br /> Motor Full load amps 10.6 4.8 3.9 10.6 4.8 3.9 <br /> Locked rotor amps 66 26.8 23.4 66 26.8 23.4 <br /> tReferto National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. <br /> NOTE-Extremes of operating range are plus and minus 10%of line voltage. <br /> ALTITUDEHIGH 1 1 <br /> GCS16-072-090 models-derate is required when operating at altitudes from 4501 to 7500 ft.(1370 to 2285 m). <br /> GCS16-120-150 models-optional High Altitude Kit HAK16-95(91J27)required for high altitude operation. No derate required. <br /> See below for correct manifold pressures for natural and LPG/Propane. <br /> Manifold Pressure <br /> Altitude GCS16-072-090 GCS16-120-150 <br /> Nat. LPG Derate Nat. LPG <br /> ft. m in.w.g. kPa in.w.g. kPa Required in.w.g. kPa in.w.g. kPa <br /> 0-4500 0-1370 3.7 0.92 10.5 2.6 0% 3.7 4.92 10.5 2.6 <br /> 4501-5500 1370-1675 3.4 0.84 10.5 2.6 4% 3.7 0.92 10.5 2.6 <br /> 5501 -6500 1675-1980 3.1 0.77 10.5 2.6 8% 3.7 0.92 10.5 2.6 <br /> 6501 -7500 1980-2285 2.9 0.72 10.5 2.6 12% 3.7 0.92 10.5 2.6 <br /> rrcda_t77-ngn.12n-1sn/Pana 10► <br />
The URL can be used to link to this page
Your browser does not support the video tag.