Sprinkler RES5 <br />N4 <br />RESIDENTIAL <br />4 I I a N7G*l 111OLFREEDOW <br />SPRINKLERSTALLATION GUIDE <br />The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br />Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br />6. INSPECTIONS, TESTS AND MAINTENANCE <br />Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. NOTICE: The owner is responsible for having the fire - <br />protection system and devices inspected, tested, and maintained in proper operating condition in accordance with this guide, and <br />applicable NFPA standards. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection <br />requirements that must be followed. <br />A. Sprinklers must be inspected on a regular basis for signs of corrosion, mechanical damage, obstructions, paint, etc. Frequency <br />of the inspections may vary due to corrosive atmospheres, water supplies, and activity around the device. <br />B. Sprinklers or cover plate assemblies that have been field painted, caulked, or mechanically damaged must be replaced im- <br />mediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards <br />require sprinklers to be tested and, if necessary, replaced immediately after a specified term of service. Refer to NFPA 25 and <br />the Authorities Having Jurisdiction for the specified period of time after which testing and/or replacement of residential sprinklers <br />is required. Never attempt to repair or reassemble a sprinkler. Sprinklers and cover assemblies that have operated cannot be <br />reassembled or re -used, but must be replaced. When replacement is necessary, use only new sprinklers and cover assemblies <br />with identical performance characteristics. <br />C. The sprinkler discharge pattern is critical for proper fire protection. Nothing should be hung from, attached to, or otherwise ob- <br />struct the discharge pattern of the sprinkler. All obstructions must be immediately removed or, if necessary, additional sprinklers <br />installed. <br />D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ <br />or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should <br />be given to employment of a fire patrol in the effected area. <br />1. Remove the system from service, drain all water, and relieve all pressure on the piping. <br />2a. For frame -style sprinklers, use the special sprinkler wrench and remove the old sprinkler by turning it counterclockwise to <br />unthread it from the piping. <br />2b. Forresidentia/flushpendentandconcea/edstylesprinklers: Remove the cei/ingringorcoverp/ateassemblybeforeunthreading the <br />sprinkler body from the piping. To remove a ceiling ring, grasp it from below the ceiling and gently turn it counterclockwise. Cover <br />plates can be removedeitherbygentlyunthreading them orpulling them offthe sprinklerbody(dependson the sprinklermodel used). <br />After the ceiling ring or cover plate assembly has been removed from the sprinkler, use the sprinkler wrench to unthread <br />the sprinkler from the piping. NOTE: For flush and concealed sprinklers with protective shells, the internal diameter of the <br />special flush and concealed sprinkler installation wrench is designed for use with the sprinkler contained within the shell. <br />Place a plastic protective shell (from the spare sprinkler cabinet) over the sprinkler to be removed and then fit the sprinkler <br />wrench over the shell. Exception: Concealed sprinklers VK457, VK458, VK468, VK474, and VK4570 are removed without <br />the plastic cap. <br />3. Follow instructions in section 4B. Installation Instructions to install the new unit. Be sure the replacement sprinkler is the <br />correct model and style, with the appropriate K-Factor, temperature rating, and response characteristics. A fully stocked <br />sprinkler cabinet should be provided for this purpose. (For flush or concealed style sprinklers, stock of spare ceiling rings or <br />cover plates should also be available in the spare sprinkler cabinet.) <br />4. Place the system back in service and secure all valves. Check for and repair all leaks. <br />E. Sprinkler systems that have been subjected to a fire must be returned to service as soon as possible. The entire system must <br />be inspected for damage, and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of <br />combustion or high ambient temperatures, but have not operated, should be replaced. Refer to the Authority Having Jurisdiction <br />for minimum replacement requirements. <br />7. AVAILABILITY <br />Viking Residential Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation <br />web site for the closest distributor or contact The Viking Corporation. <br />8. GUARANTEE <br />For details of warranty, refer to Viking's current list price schedule or contact Viking directly. <br />Form No. F_080190 18.10.25 Rev 16.1.P65 <br />