My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6623 EVERGREEN WAY 2024-10-11
>
Address Records
>
EVERGREEN WAY
>
6623
>
6623 EVERGREEN WAY 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2024 11:37:33 AM
Creation date
9/24/2024 3:45:05 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6623
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GRO& <br /> cj PIPE INSULATION THICKNESS MINI-SPLIT SYSTEM SCHEDULE Q ,�"Im <br /> TABLE 120.3 A PIPE INSULATION THICKNESS(2022 BUILDING EFFICIENCY CODE) MARK Ac CU •�j <br /> INDOOR&OUTDOOR UNITS <br /> INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER(IN INCHES) ��/ <br /> FLUID OPERATING AREA SERVED NER 07,N E C <br /> TEMPERATURE RANGE(°F) CONDUCTIVITY MEAN RATING <i 1 TO<1.5 1.5 70<4 4 70<8 8&LARGER L <br /> (IN BTU-IN/H PER FT2°F) TEMPERATTURE(°F) INSULATION THICKNESS REQUIRED(IN INCHES) TYPE WALL MOUNTED ACE MEP GROUP,INC. <br /> MANUFACTURER DAIKIN 9241 IRVINE BLVD.,SUITE 250 <br /> IRVINE,CA 92618 pi, Ill <br /> copy MIN.PIPE INSULATION REQUIRED(THICKNESS.IN INCH or R-value) MODEL NUMBER 951.808.1040 <br /> INDOOR UNIT FTKF18AXVJU acemepgroup.com O <br /> in <br /> INCHES 4.5 5.0 5.0 5.0 5.0 MODEL NUMBER RKFIBAXVJU <br /> OUTDOOR UNIT <br /> ABOVE 350 0.32-0.34 250 <br /> R-VALUE R37 R41 R37 R27 R23 SPECIFICATIONS/PERFORMANCE <br /> INCHES 3.0 4.0 4.5 4.5 4.5 NOMINAL TONS(TONS) 1.5 <br /> zslsso 0.29-0.32 zoo ��N ME`LT <br /> R-VALUE R24 R34 R35 R26 R22 4 of was <br /> yi F <br /> REFRIGERANT R-32 <br /> INCHES 2.5 2.5 2.5 3.0 3.0 <br /> 5 z <br /> COOLING CAPACITY-RATED-(BTU/HR) 18,100 <br /> 201-250 0.27-0.30 150 n 22025035 cpr <br /> R-VALUE R21 R20 R17.5 R17 R14.50 of RFc/STER�'��w <br /> HEATING CAPACITY-RATED-(BTU/HR) - ��`rIONAL L�Gl <br /> INCHES 1.5 1.5 2.0 2.0 2.0 <br /> IDU AIRFLOW-COOLING-(CFM) 754/716/605/467/395 <br /> 141-200 0.25-0.29 125 MAX/H/M/L <br /> R-VALUE R11.5 R11 R14 R11 R10 <br /> IDU AIRFLOW-HEATING-(CFM) <br /> - <br /> INCHES 1.0 11.5 1.5 1.5 1.5 MAX/H/M/L REVISION <br /> 105-140 0.22-0.28 100 EAT-IDS-(°F) 80 <br /> R-VALUE R7.7 R12.5 R11 R9 IRS <br /> EAT-W B-(°F) 67 <br /> NOMINAL PIPE DIAMETER(IN INCHES) <br /> <1 1 TO<1.5 1 1.5 TO<4 1 4 TO<8 8&LARGER SEER2/EER2 21/12 <br /> PROJECT NO:24115 <br /> SPACE COOLING SYSTEMS(CHILLED WATER,REFRIGERANT&BRINE) MINIMUM PIPE INSULATION REQUIRED(THICKNESS IN INCHES OR R-VALUE)' HSPF2 - <br /> DATE:05/13/2024 <br /> NONRES RES NONRES RES MAX PIPE LENGTH(TOTAL) 99 <br /> 40-60 0.21-0.27 75 <br /> INCHES 0.5 0.75 0.5 0.75 1.0 1.0 1.0 DRAW BY. <br /> MAX PIPE LENGTH(VERTICAL) 66 <br /> NONRES RES NONRES RES <br /> R-VALUE R3 R6 R3 R5 R7 IRS RS ELECTRICAL DATA CHECK BY: <br /> INCHES 1.0 1.5 1.5 1.5 1.5 V/PH/HZ 208-230/60/1 SCALE: <br /> BELOW 40 0.20-0.26 50 MCA(A) 14.23 <br /> R-VALUE R8.5 R14 R12 R9 R9 <br /> FOOTNOTE TO TABLE 120.3-A: <br /> MOP(A) 20.0 <br /> 1.THESE THICKNESS ARE BASED ON ENERGY EFFICIENCY CONSIDERATIONS ONLY. ISSUES SUCH AS WATER VAPOR PERMEABILITY OR SURFACE CONDENSATION SOMETIMES REQUIRE VAPOR RETARDERS OR <br /> ADDITIONAL INSULATION. PHYSICAL DATA-INDOOR UNIT <br /> UNIT WIDTH(IN) 39-9/16 <br /> UNIT DEPTH(IN) 10-3/4 <br /> UNIT HEIGHT(IN) 11-11/16 <br /> UNIT WEIGHT(LB) 32.0 W <br /> PHYSICAL DATA-OUTDOOR UNIT N > <br /> UNIT WIDTH(IN) 36-5/8 � N <br /> UNIT DEPTH(IN) 13-13/16 \�J QQ <br /> UNIT HEIGHT(IN) 27-13/32 / ui <br /> ui <br /> UNITWEIGHT(LB) 140.0 w (E <br /> REMARKS/DETAILS <br /> FAN COIL POWER FROM HEAT PUMP YES \w emu/ <br /> REMARKS 1,2,3,4,5,6,7 ( I 1 I LJ- <br /> LLJ ui <br /> DETAILS M > <br /> NOTES: `M N w <br /> 1.PROVIDE ALL REQUIRED MATERIAL FOR A FULLY FUNCTIONAL SYSTEM SUCH AS 1 1 <br /> REFRIGERANT LINES,CONTROL WIRING,CONDUITS,ETC. <br /> 2.PROVIDE PROGRAMMABLE,TITLE 24 COMPLIANT THERMOSTAT RECOMMENDED BY <br /> EQUIPMENT MANUFACTURER. <br /> 3.PROVIDE PERMANENT LABEL FOR THE FAN COIL&HEAT PUMP UNITS. <br /> 4.PROVIDE HP WITH LOCKABLE REFRIGERANT VALVE. <br /> 5.SET FAN COIL ON COOLING MODE ONLY. <br /> 6.PROVIDE MINI-SPLIT CONDENSATION PUMP KIT DACA-CP4-1 PER MANUFACTURER <br /> RECOMMENDATION. <br /> 7.PROVIDE WIRED REMOTE CONTROLLER KIT. <br /> 8.PROVIDE AIR ADJUSTMENT GRILLE. <br /> 9.CONTRACTOR SHALL VERIFY MODEL NUMBERS&MATCH INDOOR WITH OUTDOOR UNIT <br /> PRIOR TO ORDER AND INSTALLATION. <br /> SHEET TITLE: <br /> MECHANICAL <br /> SCHEDULE <br /> SHEET NUMBER: <br /> M 002 <br />
The URL can be used to link to this page
Your browser does not support the video tag.