My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6623 EVERGREEN WAY 2024-10-11
>
Address Records
>
EVERGREEN WAY
>
6623
>
6623 EVERGREEN WAY 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2024 11:37:33 AM
Creation date
9/24/2024 3:45:05 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6623
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SINGLE LINE DIAGRAM GENERAL NOTES <br /> �Q GROUp <br /> 1. AVAILABLE FAULT CURRENT FROM UTILITY COMPANY IS EXISTING TO REMAIN. <br /> 2. ALL NEW EQUIPMENT PER PLANS SHALL MATCH THE AIC RATING OF EXISTING BREAKERS IN PANEL <br /> 3. ALL FUSED DISCONNECTS SHALL BE PROVIDED WITH REJECTION CLIPS. <br /> 4. ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED FOR FINAL INSPECTIONS. • ;1■.'1 <br /> 5. PROVIDE BONDING FOR ALL CAN AND TELEPHONE SYSTEMS WITH 1#6AWG.VERIFY LOCATION. /I/II <br /> SCOPE 6. ALL CONDUCTORS SHALL BE 60OV.RATED WITH THHN/THWN INSULATION AT 75°CELSIUS UNLESS NOTED OTHERWISE.ALL <br /> NO OF NO NO PANEL TERMINATIONS SHALL BE 75 75°CELSIUS RATED. <br /> WORK (E) WORK 2 OA WORK WORK 7. ALL CIRCUIT BREAKER TERMINALS IN SWITCHBOARDS AND PANELBOARDS SHALL BE U.L LISTED AND APPROVED. <br /> rA3P (E) (E) 8. ALL FINAL TERMINATIONS OF CONDUCTORS TO ELECTRICAL EQUIPMENT AND DEVICES SHALL BE TORQUE WRENCH <br /> ZNO <br /> CAN E Eat <br /> PANEL PANEL TIGHTENED TO THE MANUFACTURER'S RECOMMENDED SPECIFICATION,NO EXCEPTION. <br /> A B 9. AS REQUIRED ALL OVERSIZED FEEDERS THAT WERE ADJUSTED IN SIZE TO COMPENSATE FOR VOLTAGE DROP SHALL BE <br /> PROVIDED WITH ADAPTER LUGS OR SPLICE BOX.ADAPTER LUGS SHALL BE PROVIDED IF SIZE IS AVAILABLE.OTHERWISE ACE MEP GROUP,INC. <br /> -MPROVIDE CABLE SPLICES IN THE SPLICE BOX TO REDUCE CABLES TO THE MAXIMUM SIZE THAT THE BREAKER LUGS CAN 9241 IRVINE BLVD,SUITE 250 <br /> 5KVA ACCOMMODATE. IRVINE,CA 92618801120-208V 10. CABLE LENGTH SHOWN ON DRAWINGS ARE FOR VOLTAGE DROP AND FAULT CURRENT CALCULATIONS.CONTRACTORm,4W,A-Y 951.808.1040 Z wZ wZ wSHALL VERIFY EXACT ROUTING OF FEEDERS AND DETERMINE THE ACTUAL LENGTH FOR PRICING. 8C0TTICODI 11. ALUMINUM FEEDERS ARE ACCEPTABLE ONLY WHERE ALLOWED IN CODES AND LOCAL JURISDICTIONS.WHERE ALUMINUM <br /> DER w w w w w LU NO AC#1 NO FEEDERS ARE BEING SUBMITTED IN LIEU OF COPPER,CONTRACTOR SHALL SUBMIT A REVISED FEEDER SCHEDULE <br /> EXISTING MAIN SERVICE"MSA" <br /> 350A,277/48OV,3PH,4W WORK WORK INDICATING PROPOSED SIZES,FOR REVIEW BY EOR.COST INCURRED BY FOR FOR REVIEWING REVISED SCHEDULE SHALL .,....�o,..o <br /> AVAILABLE FAULT CURRENT:EXISTING BE BILLABLE TO THE CONTRACTOR. <br /> AIC RATING:EXISTING 12. SIZES OF BREAKERS,SWITCHES,FUSES AND FEEDERS ARE BASED ON DESIGNED EQUIPMENT SIZES.THESE SIZES SHALL <br /> r T ----- --- --- -------- ---- BE ADJUSTED TO SATISFY REQUIREMENTS OF ACTUAL INSTALLED OR SUBSTITUTED EQUIPMENT. <br /> (E)350A BUS <br /> 13. PRIOR TO BIDDING,CONTRACTOR SHALL COORDINATE SIZES OF CIRCUIT BREAKERS,FUSES,SWITCHES AND FEEDERS WITH �Cl AM EN <br /> THE EQUIPMENT SCHEDULES SHOWN ON THE MECHANICAL DRAWING AND OTHER TRADES WHERE APPLICABLE.THE MORE 4�Q4 WASy/N <br /> (E) (E) (E) (E) \(E) (E) RESTRICTIVE REQUIREMENTS SHALL GOVERN WHERE THERE ARE DISCREPANCIES BETWEEN INFORMATION SHOWN ON y co y <br /> (E)350A 350A )125A 1150A 1125A I SOA 150A THE ELECTRICAL DRAWINGS AND OTHER TRADES. <br /> 14. FOR NEW WORK COMPLETE POWER DISTRIBUTION SUBMITTAL SHALL BE PROVIDED BY CONTRACTOR FROM THE <br /> Gya <br /> 1 M MANUFACTURER FOR REVIEW AND APPROVAL PRIOR TO PURCHASE AND INSTALLATION OF ANY POWER DISTRIBUTION �+�'R 22025035FCISTET-�'��w <br /> T EQUIPMENT. IONAL L�'V� <br /> •• <br /> L-- ------i-- -----------1--------------------------J <br /> (E)GROUNDING SYSTEM <br /> REVISION <br /> (E)UTILITY PROJECT NO:24115 <br /> TRANSFORMER <br /> DATE:05/13/2024 <br /> DRAW BY: <br /> CHECK BY: <br /> SCALE: <br /> SINGLE LINE DIAGRAM 1 <br /> 1 <br /> W <br /> I..L Qa O <br /> w > CV <br /> \ Z °O <br /> W � <br /> Lu <br /> W W <br /> SERVICE LOAD CALCULATIONS Z W � <br /> EXISTING CONNECTED LOAD W/VA AMP @480V,3P M W <br /> PEAK USAGE 112KW 134.8A `^'J1 > <br /> ADD 25%PER NEC 220.87(2) 28KW 33.7A M` '`/V� W <br /> TOTAL EXISTI NG CONNECTED LOAD 140KW 168.5A rY'1 <br /> POWER FACTOR(DIVIDE BY 0.81 275KVA 230.6A �1J <br /> NEW CONNECTED LOAD / , <br /> NEW HVAC LOAD 3.42OKVA 41A v, <br /> NEW RECEPTACLE LOAD 0.180KVA 0.2A <br /> TOTAL NEW CONNECTED LOAD 3.600KVA 4.3A <br /> TOTAL CONNECTED LOAD <br /> EXISTING LOAD 175KVA 210.6A <br /> NEW LOAD 3.600KVA 4.3A <br /> 178.60KVA 2149A <br /> SERVICE SI ZE 350A 277/480V 3 P 4 W <br /> SHEET TITLE: <br /> SINGLE LINE & <br /> LOAD CALC <br /> SHEET NUMBER: <br /> E 0 0 2 <br /> GEAR LOAD CALCULATIONS 2 <br />