My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6623 EVERGREEN WAY 2024-10-11
>
Address Records
>
EVERGREEN WAY
>
6623
>
6623 EVERGREEN WAY 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2024 11:37:33 AM
Creation date
9/24/2024 3:45:05 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6623
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEMO GENERAL NOTES <br /> ��Q GROUo <br /> 1. CIRCUITING TO REMAIN:EXISTING CIRCUITING TO REMAIN SHALL BE REROUTED OR RECONNECTED,AS REQUIRED, 44., <br /> WHERE AFFECTED BY NEW WORK IN ORDER TO MAINTAIN CONTINUITY OF CIRCUIT. ,I <br /> 2. REUSE OF EXISTING CIRCUITRY:EXISTING CIRCUITRY SERVING LIGHTING FIXTURES AND/OR RECEPTACLES FOR A ` 1 <br /> GIVEN AREA SHALL BE REUSED WHERE CONVENIENT TO SERVE THE NEW LAYOUT.PROVIDE CIRCUIT Q ��■.rk <br /> MODIFICATIONS INDICATED OR AS OTHERWISE REQUIRED TO MAINTAIN THE CONTINUITY OF THE EXISTING <br /> CIRCUITS THAT REMAIN. <br /> 3. EXISTING CONDUIT:ALL EXISTING CONDUITS AND WIRING THAT WILL NOT BE REUSED SHALL BE REMOVED WHERE <br /> THEY WILL BE EXPOSED UPON COMPLETION OF NEW WNNIF <br /> ORK.EXISTING CONDUIT TO REMAIN CONCEALED IN WALLS <br /> SHALL BE ABANDONED.EXISTING CONDUIT TO REMAIN BELOW FLOOR SLAB SHALL BE CUT OFF ONE INCH BELOW ,//� <br /> ROUGH FLOOR AND GROUTED FLUSH.ALL EXISTING WIRING IN CONDUITS TO BE ABANDONED SHALL BE <br /> DISCONNECTED FROM POWER SOURCE AND REMOVED. GIN E Ea�� <br /> 4. REPAIR DAMAGE:EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS.REPAIR,AT NO ADDITIONAL COST TO <br /> OWNER,ANY DAMAGE CAUSED TO EXISTING CONSTRUCTION AND/OR EQUIPMENT TO REMAIN. <br /> 5. ASSOCIATED APPURTENANCES:REMOVE ALL ELECTRICAL APPURTENANCES(DISCONNECTS,STARTERS,WIRING, ACE MEP GROUP,INC. <br /> CONDUIT,ETC.)ASSOCIATED WITH EQUIPMENT TO BE REMOVED BY OTHERS. 9241 IRVINE BLVD.,SUITE 250 <br /> 6. KNOCKOUT PLUGS AND COVERS:ALL CONDUIT REMOVED SHALL BE REMOVED IN ITS ENTIRETY,INCLUDING IRVINE,CA 92618 p p <br /> FITTINGS,MOUNTING DEVICES,MOUNTING HARDWARE,ETC.PROVIDE CONDUIT PLUGS AND BLANKS FOR ALL ' <br /> OPENINGS CREATED BY THE REMOVAL OF CONDUIT.PROVIDE BLANK COVER PLATES FOR ALL OPENED OUTLET 951.808.1040 <br /> BOXES CREATED BY THE REMOVAL OF THE EQUIPMENT AND/OR DEVICES. BCOfIlE:P9fOUp.C011l C]' !' <br /> 7. DEMOLISHED MATERIALS:ALL MATERIALS REMOVED UNDER DEMOLITION,NOT TO BE RELOCATED OR <br /> DESIGNATED TO BE TURNED OVER TO THE OWNER,SHALL BECOME PROPERTY OF THE CONTRACTOR AND SHALL <br /> BE REMOVED COMPLETELY FROM THE SITE.SCHEDULE OUTAGES:ALL WORK AND ALL POWER OUTAGES IN THE <br /> EXISTING BUILDING SHALL BE SCHEDULES AT TIMES CONVENIENT TO THE OWNER.NOTIFICATION:NOTIFY THE <br /> OWNER PRIOR TO TURNING OFF ANY CIRCUITS.EXISTING CIRCUITS:IF DURING THE COURSE OF CONSTRUCTION,IT <br /> IS DETERMINED BY THE CONTRACTOR THAT AN EXISTING CIRCUIT BECOMES SPARE,THE CONTRACTOR SHALL <br /> UPDATE THE PANELBOARD DIRECTORY TO INDICATE SUCH,EVEN IF IT IS NOT EXPLICITLY MARKED ON THE <br /> ® ELECTRICAL PLANS. WMggENT <br /> 8. EXISTING PANELBOARDS:EXISTING PANELBOARDS ARE TO REMAIN ENERGIZED UNTIL ALL CIRCUITS HAVE BEEN aF y�N F <br /> REMOVED.THE WORK TO RELOCATE CIRCUITS FROM THE EXISTING PANELBOARDS TO THE NEW PANELBOARDS R co <br /> (ER) SHALL BE COORDINATED WITH WVU AND BE PERFORMED AT TIMES THAT DO NOT DISRUPT ONGOING WORK, <br /> ER z <br /> CLASS,OR RESEARCH IN ANY OF THE AFFECTED SPACES. <br /> � 22025635 Gya <br /> �.F,Pea 1STos <br /> DEMO PLAN NOTES �ssIONALvt <br /> ® EXISTING NER CABINET LOCATION.CIRCUITS TO BE SHIFTED TO CORRECT HEIGHT/LOCATION PER STANDARD <br /> WITH NEW WIRES NO SPLICE.DEMO CONDUIT AND WIRE UP TO NEAREST J-BOX.ELECTRICAL CONTRACTOR TO REVISION <br /> VERIFY THAT CIRCUITS ARE C2-25,27. <br /> PROJECT NO:24115 <br /> DATE:05/13/2024 <br /> DRAW BY: <br /> NORTH <br /> CHECK BY: <br /> a D ABBREVIATIONS <br /> SCALE: <br /> (E)EXISTING TO REMAIN <br /> 0 1' 2' q' g (D)EXISTING TO BE DEMOLISHED <br /> (ER)EXISTING TO BE RELOCATED <br /> 1/2"=1'0" <br /> NOT USED DEMO-ENLARGED PLAN 1 PROPOSED GENERAL NOTES <br /> 1. COORDINATE EXACT LOCATION OF HVAC&PLUMBING EQUIPMENT WITH MECHANICALIPLUMBING CONTRACTOR. <br /> 2. INSTALLATION OF THE MECHANICAL&PLUMBING EQUIPMENT SHALL COMPLY WITH ALL CODES®ULATIONS <br /> ALONG WITH MANUFACTURER RECOMMENDATION&GUIDELINES. <br /> 3. CONTRACTOR SHALL COORDINATE THE CONDUIT RUNS WITH RELEVANT TRADES PRIOR TO PURCHASE& <br /> INSTALLATION OF THE CONDUITS&CABLES.THIS DRAWING IS DIAGRAMMATIC&SHALL NOT BE USED FOR <br /> PRICING. ui <br /> 4. CONTRACTOR SHALL PROVIDE COMPLETE MEASUREMENT OF THE CONDUIT RUNS&PROVIDE LIST OF ALL <br /> CONDUIT LENGTHS TO ACE&FOR FOR VERIFICATION OF THE VOLTAGE DROP. } <br /> 5. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION&ELEVATION OF ALL DEVICES. <br /> 6. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL EQUIPMENT&INSTALL EQUIPMENT AS PER <br /> MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATION.FURNISH AND INSTALL NEW BRANCH CIRCUITRY AS > N <br /> SHOWN PER PLANS&AS PER ALL APPLICABLE CODES®ULATIONS. ui 7. PRIOR TO BEGINNING OF THE ROUGH IN OF THE ELECTRICAL INSTALLATION,THE ELECTRICAL CONTRACTOR / OO <br /> SHALL COORDINATE WITH THE LOCAL AUTHORITIES AND VERIFY PERMISSIBLE WIRING METHODS AND TYPES. <br /> WHERE THERE ARE DISCREPANCIES OR QUESTIONS REGARDING THESE METHODS,THE ELECTRICAL w <br /> RETAIUBRANCH SITE NER OR TR CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK FOR <br /> 1 DEDICATED 20Liu <br /> AMP/120V CIRCUIT MOUNTED INSIDE OF CABINET FURTHER DIRECTION. W <br /> 1 NEW BRANCH 20A/120V CIRCUIT MOUNTED NEXT TO THE DEDICATED OUTLET 8. ALL EXPOSED WIRING METHODS SHALL BE COMPLETED UTILIZING METALLIC RACEWAYS.CONTRACTOR SHALL <br /> PROVIDE APPROVED PROTECTION METHODS FROM PHYSICAL DAMAGE AND CONFIRM WITH INSPECTOR PRIOR TO PURCHASE&INSTALLATION. 0 <br /> 3/4"CONDUITS FOR 9. ALL EXPOSED WIRING METHODS,THAT ARE EXPOSED TO POSSIBLE PHYSICAL DAMAGE,SHALL BE EITHER <br /> ELECTRICAL 3"CONDUITS FOR LOW GALVANIZED RIGID CONDUIT OR INTERMEDIATE RIGID CONDUIT. LL <br /> VOLTAGE CABLING -20AI720V DEDICATED 10. CONTRACTOR TO REQUEST FOR THE MOST CURRENT SET OF LOW VOLTAGE PLAN PRIOR TO INSTALLATION OF LLJ <br /> QUANTILY AS REQUIRED 20A/12V BRANCH CIRCUIT THE CONDUIT AND WIRING OF LOW VOLTAGE DEVICES. W <br /> CIRCUIT L5-20R 11. CONTRACTOR TO INCLUDE IN THEIR BIDS ALL COSTS FOR PREPARATION AND INSTALLATION OF LOW VOLTAGE LPL/e"FIRE RETARDANT PLYWOOD RECEPTACLE 5-20R QUAD RECEPTACLE 1 SYSTEMS. W <br /> GROUND BUS C2-27 <br /> 12. CONTRACTOR TO PROVIDE POWER FOR LOW VOLTAGE EQUIPMENT&DEVICES PROVIDE AS REQUIRED. � W <br /> O O O �R O3 13. MAINTAIN SEPARATION BETWEEN ELECTRICAL AND LOW VOLTAGE CONDUITS. N \ <br /> B®9 BABA <br /> 0 0 O O C2-25 "® m w <br /> -20A/120V DEDICATED <br /> CIRCUIT L5-20R <br /> RECEPTACLE <br /> ATTACHED OR REAR 20A/12V BRANCH CIRCUIT (N)AC-1© N-P,10 <br /> PLANE OF CABINET 5-20R QUAD RECEPTACLE <br /> 5 GFl D <br /> 96"A.F F M-12 <br /> 84"A.F.F m <br /> WALL STUDS 16"ON (N)CU-1 <br /> CENTER <br /> PROPOSED PLAN NOTES <br /> "A.F. <br /> O RELOCATED AND UPDATED CABINET.DUPLEX AND DEDICATED RECEPTACLE TO BE RELOCATED TO MATCH <br /> DETAIL HEIGHT,WITH DUPLEX REPLACED BY QUAD OUTLET. SHEET TITLE: <br /> O2 NOT USED. <br /> 48"WIDE O LOCATION OF NER CABINET.REFER TO DETAIL ON THIS SHEET FOR MORE INFORMATION INCLUDING OUTLET <br /> WALL STUDS 16"ON HEIGHTS.CIRCUITS FOR NER CABINET ARE TO BE RELOCATED FROM PREVIOUS LOCATION SHOWN ON E100. <br /> CENTER <br /> THE RECEPTACLE MUST BE LABELED WITH THE PANEL AND CIRCUIT ID USING A ® LOCATION OF GROUND BUS.PROVIDE GROUND WIRE BETWEEN NER OUTLETS AND GROUND BUS BAR.CONNECT <br /> P-TOUCH OR BRADY LABELER.NO HAND WRITTEN LABELS GROUND BUS BAR BACK TO PANEL C2 GROUND VIA 1#6 COPPER IN 1/2"CONDUIT.CONDUIT TO BE GROUNDED. <br /> O PROVIDE POWER CONNECTION PER MANUFACTURER'S REQUIREMENTS.COORDINATE EXACT LOCATION WITH ENLARGED PLANS <br /> MECHANICAL CONTRACTOR.CONTRACTOR TO VERIFY EXISTING SERVICE RECEPTACLE WITHIN 25,OF <br /> NORTH EQUIPMENT LOCATION ON ROOFTOP.SERVICE RECEPTACLE IS SHOWN NEW,CONFIRM IF THERE IS EXISTING <br /> AND DO NOT INSTALL IF NOT CODE REQUIRED. <br /> a D © PROVIDE 2P LOCKABLE MOTOR RATED SWITCH FOR FAN COIL.FAN COIL POWER IS FED VIA OUTDOOR <br /> CONDENSER WITH CONDENSATE PUMP FED VIA FAN COIL.REFER TO MANUFACTURER DETAIL ON SHEET E003 <br /> AND MECHANICAL DRAWINGS FOR MORE INFORMATION. SHEET NUMBER: <br /> 0 1' 2' 4' 6' ABBREVIATIONS <br /> (E)EXISTING <br /> (R)RELOCATED <br /> NER CABINET DETAIL 3 PROPOSED-ENLARGED PLAN 2 (N)NEW <br />
The URL can be used to link to this page
Your browser does not support the video tag.