Laserfiche WebLink
4V SimplEx <br /> TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories <br /> Sensor Bases <br /> 4098-9792,Standard Sensor Base <br /> 4098-9789,Sensor Base with wired connections for: <br /> • 2098-9808 Remote LED alarm indicator or 4098-9822 relay(relay is unsupervised and requires separate 24 VDC) <br /> Supervised Relay Bases(not compatible with 2120 CDT): <br /> 4098-9791,4-Wire Sensor Base,use with remote or locally mounted 2098-9737 relay,requires separate 24 VDC <br /> 4098-9780,2-Wire Sensor Base,use with remote or locally mounted 4098-9860 relay,no separate power required <br /> Supervised relay operation is programmable and can be manually operated from control panel <br /> Includes wired connections for remote LED alarm indicator or 4098-9822 relay(relay is unsupervised and requires separate 24 VDC) <br /> Sensor Base Options <br /> 2098-9737,Remote or local mount supervised relay: <br /> DPDT contacts for resistive/suppressed loads,power limited rating of 3 A @ 28 VDC;non-power limited rating of 3 A @ 120 <br /> VAC(requires external 24 VDC coil power) <br /> 4098-9860,Remote or local mount supervised relay: <br /> ALARM <br /> • SPDT dry contacts,power limited rating of 2 A @ 30 VDC,resistive;non-power limited rating of 0.5 A @ 125 VAC,resistive <br /> 4098-9822,LED Annunciation Relay: <br /> •Activates when base LED is on steady,indicating local alarm or trouble <br /> • DPDT contacts for resistive/suppressed loads,power limited rating of 2 A @ 28 VDC;non-power limited rating of 1/2 A @ gSi"ple" <br /> 120 VAC,(requires external 24 VDC coil power) <br /> 4098-9832,Adapter plate: <br /> • Required for surface or semi-flush mounting to 4"square electrical box and for surface mounting to 4"octagonal box <br /> • Can be used for cosmetic retrofitting to existing 6-3/8"diameter base product Figure 2: Remote <br /> 2098-9808,Remote red led Alarm Indicator: red LED Alarm <br /> • Mounts on single gang box(shown in illustration) <br /> Indicator <br /> Description <br /> TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. <br /> Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. <br /> Since TrueAlarm sensors use the same base,different sensor types can be easily interchanged to meet specific location requirements.This feature <br /> also allows intentional sensor substitution during building construction.When conditions are temporarily dusty,instead of covering the smoke sensors <br /> (causing them to be disabled),heat sensors may be installed without reprogramming the control panel.Although the control panel will indicate an <br /> incorrect sensor type,the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. <br /> Features <br /> Sealed against rear air flow entry <br /> Interchangeable mounting <br /> EMI/RFI shielded electronics <br /> Heat sensors: <br /> Selectable rate compensated,fixed temperature sensing with or without rate-of-rise operation <br /> Rated spacing distance between sensors: <br /> Fixed Temp.Setting UL&ULC Spacing IFM Spacing,Either Fixed Temperature Setting <br /> 135°F(57.2°C) 60 ft x 60 ft(18.3 m) 20 ft x 20 ft(6.1 m)for fixed temperature only;RTI=Quick <br /> 155-F(68°C) 40 ft x 40 ft(12.2 m) 50 ft x 50 ft(15.2 m)for fixed temperature with either rate-of-rise selection;RTI::1 = <br /> Ultra Fast <br /> Note:*1900 F(880 C)ratings apply only to the 4098-9734 sensor. <br /> Smoke Sensors: <br /> Photoelectric technology sensing <br /> 360'smoke entry for optimum response <br /> Built-in insect screens <br /> Page 2 54098-0019 Rev.25 01/2020 <br />