Laserfiche WebLink
Current Draw <br /> EGC-HDVM Temporal Horn-strobe:High dB Setting EGC-HDVMH High cd Temporal Horn-strobe:High dB <br /> Setting <br /> UL 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd <br /> Rating RMS RMS RMS RMS RMS RMS RMS RMS <br /> 16 Vdc 147 190 316 372 341 399 506 570 <br /> 16 Vfwr 189 253 417 451 487 578 670 711 <br /> EGC-HDVM Temporal Horn-strobe:High dB Setting EGC-HDVMH High cd Temporal Horn-strobe:High dB <br /> Setting <br /> Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd <br /> Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean <br /> 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 <br /> 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 <br /> 24 Vdc 80 71 108 101 185 180 212 207 220 217 252 249 304 301 341 338 <br /> 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 <br /> 16 Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 <br /> 20 Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 <br /> 24 Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 <br /> 33 Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 <br /> EGC-HDVM Temporal Horn-strobe:Low dB Setting EGC-HDVMH High cd Temporal Horn-strobe:Low dB <br /> Setting <br /> Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd <br /> Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean <br /> 16 Vdc 108 91 149 139 275 269 327 322 317 315 378 376 480 477 544 542 <br /> 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 290 364 362 414 411 <br /> 24 Vdc 76 66 103 97 180 175 205 201 212 211 245 243 297 295 334 332 <br /> 33 Vdc 64 57 85 80 138 135 153 150 159 157 181 179 215 213 234 232 <br /> 16 Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 <br /> 20 Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 <br /> 24 Vfwr 118 60 162 82 262 149 301 171 335 172 370 195 440 235 485 264 <br /> 33 Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 <br /> Notes and Comments <br /> 1. Current values are shown in mA. <br /> 2. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. <br /> 3. Edwards recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. <br /> 4. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations.Use the Vfwr RMS current ratings for unfiltered power supply calculations. <br /> 5. Fuses,circuit breakers and other overcurrent protection devices are typically rated for current in RMS values.Most of these devices operate based upon the heating affect <br /> of the current flowing through the device.The RMS current(not the mean current)determines the heating affect and therefore,the trip and hold threshold for those devices. <br /> 6. Our industry has used'mean'currents over the years. However,UL will direct the industry to use the 2004 RMS values in the future. <br /> dBA output Light output - (effective cd) <br /> UL464 Average Peak <br /> High d6 Percent of UL rating versus angle <br /> Setting Temporal Steady Temporal/ Temporal/ <br /> Per 10 of UL <br /> Steady Steady <br /> 120 110 100 90 80 70 fi0 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 <br /> 16 Vdc 79.8 83.2 90.6 93.6 <br /> 24 Vdc 83.3 85.4 93.6 96.6 <br /> 33 Vdc 85 87.8 95.7 98.7 -75' / <br /> Low dB UL464 Average Peak -so so <br /> Setting Temporal Steady Temporal/ Temporal/ <br /> Steady Steady <br /> 16 Vdc 75 79.3 86.3 88.7 'S\ /a5° <br /> 24 Vdc 78 83 88.8 92.4 <br /> 30 30° <br /> 33 Vdc 1 80.9 85.9 1 91.8 1 95.1 <br /> 5° 5° <br /> 0° <br /> Notes <br /> 1.All values shown are dBA measured at 10 feet(3.01 m);2.UL464 values measured <br /> in reverberation room;3.Average and Peak values are measured in anechoic cham- <br /> ber. <br /> Page 3 of 4 DATA SHEET S85001-0559 <br /> Not to be used for installation purposes. Issue 9.2 <br />