Laserfiche WebLink
Envelope Leakage Test <br /> Testing Company: Technician: <br /> Name: Name: <br /> Address: Credentials: <br /> Email: <br /> Building Information: Customer Information: <br /> Project ID: 1831 100th St W#22 Name: <br /> Address: Address: <br /> Geo-Tag Data: Latitude: <br /> Longitude: <br /> Timestamp: <br /> Measured Leakage: 672.3 CFM50 <br /> Test ID: Test 1 <br /> Purpose of Test: 50 Pa Env. Leakage <br /> Measured ACH50: 2.86 Effective Leakage Area: 37.0 in <br /> Building Volume: 14,110.0 W Enclosure Surface Area: 0.0 ft2 <br /> Coefficient (C): 52.9 Exponent (n): 0.650 (assumed) <br /> Test Standard: RESNET 380 One-Point Test Mode: Depressurize <br /> Test Characteristics: Indoor Temp: 66 °F Outdoor Temp: 64 °F <br /> Altitude: 690.0 ft Time Average Period: 10 seconds <br /> Test Date and Time: 2024-06-24 12:49:21 <br /> 800 <br /> 700 <br /> 00 • Depressurize <br /> E 500 <br /> U <br /> 400 <br /> 0) <br /> M <br /> a� <br /> 300 <br /> J <br /> 0) <br /> 200 <br /> CD <br /> 100 <br /> 4 5 6 7 8 910 20 30 40 50 60 <br /> Building Pressure (Pa) <br />