Laserfiche WebLink
NORTH <br /> verizoal <br /> W,c.,wnats Below. <br /> co 7 Call before you dig <br /> / P6oLE�TIONDMaEB PROJECT: <br /> LEGEND: <br /> 1703MNTR.005 ROW EVT 1328 <br /> BORE/MISSILE BORE IER.ITTIR—TITI <br /> LU — — — OPEN TRENCH CITY OF EVERETT <br /> Q SIDEWALK 111LECTLICATI11 <br /> 4621 COLBY AVE 4634ALGERAVE <br /> E.O.P EDGE OF PAVEMENT <br /> EVERETT,WA <br /> 4617 COLBY AVE B.O.0 BACK OF CURB <br /> U R.O.W. RIGHT OF WAY <br /> r C.L.--- STREET CENTERLINE <br /> • POTHOLE LOCATION Ov z — <br /> 4625 COLBY AVE L/; V o LU ° <br /> IF-- v <br /> (� <br /> In <br /> 0' 10' 20' 40' _ Z <br /> Q O o zN U o <br /> O v) I_o <br /> UJ <br /> INSTALL 28 LF OF U a w O 0 <br /> 1 -2" HDPE CONDUIT � N Z <br /> uj <br /> (BORE) Lu ': o Q o <br /> INSTALL 189 LF OF u <br /> STA: 4+58 1 -2" HDPE CONDUIT a <br /> oo DIG (1) 3' x 3' BOREPIT (BORE) <br /> + — L + <br /> QDRIVEWAY DRIVEWAY R.O.W. Q co FORESSIo E <br /> R.O.W.- a 1334.887.601, <br /> ^+00 6+00 30Ue EEC—Chavez St. Wf11334.8.60 <br /> Ld _ — _ v w <br /> Austin,TX]6]02 <br /> J E.O.P E.O.P J <br /> GAS — TAS c� <br /> Q Q <br /> C.L. — — _ _ _ COLBY AVENUE <br /> —C.L. <br /> ENGINEER: AS <br /> �F DRAWN BY: AS <br /> REVISIONS <br /> n^TF DESCRIPTION INITIAL <br /> IN TETOCONTRACTOR <br /> E.O.P ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> E.O.P TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> R.O.W. CAUTION" <br /> R.O.W. ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> SPECIFICATIONS. <br /> ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> 4618 COLBY AVE 4622 COLBY AVE 4626 COLBY AVE FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> ACCURATE OR COMPLETE. <br /> EXCEPT AS MAY BE OTHERWISE PROVIDED BY—TRACT <br /> THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY OF MCI COMMUNICATIONS SERVICES,INC..BOT <br /> E <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO BEING ISSUED IN STRICT CONFIDENC AND SHALL NOT B <br /> REPRODUCED, COPIED, OR USED FOR ANY PURPOSE <br /> MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMISSION. <br /> DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> F- UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> WITHIN CONSTRUCTION PATH. <br /> I I I ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-03 <br />