Laserfiche WebLink
NORTH <br /> 0 verizoal <br /> Ic,w+.wnars6elow. <br /> Call before you dig <br /> PROJECT: <br /> I I LEGEND: 1703M P67 NTME3M NMITYR <br /> R.005 ROW EVT 1328 <br /> BORE/MISSILE BORE <br /> OPEN TRENCH CITY OF EVERETT <br /> SIDEWALK <br /> E.O.P EDGE OF PAVEMENT 4634ALGERAVE <br /> 3 EVERETT,WA <br /> U) B.O.0 BACK OF CURB <br /> I R.O.W. RIGHT OF WAY <br /> C.L.--- STREET CENTERLINE <br /> 4705 COLBY AVE • POTHOLE LOCATION Ov Z — <br /> 4631 COLBY AVE °-° w o <br /> Lu <br /> I L < J <br /> I 0' 10, 20' 40, > _ <br /> EX WATER " Z Lu z <br /> v�� I MAINTAIN 24" MIN I g N o Z o <br /> CLEARANCE ULn z j <br /> POTHOLE AND RESTORE Z a w Z <br /> TO STANDARDS < o m of <br /> EX GAS EX STORM INSTALL 40 LF OF N Fm U) ZQ of <br /> MAINTAIN 24" MIN I MAINTAIN 24" MIN 1 -2" HDPE CONDUIT U o <br /> INSTALL 182 LF OF CLEARANCE <br /> 1 -2" HDPE CONDUIT CLEARANCE (BORE) a <br /> BORE POTHOLE AND RESTORE I <br /> ( ) TO STANDARDS POTHOLE AND RESTORE <br /> co R.O.W. I I 1 TO STANDARDS 00 FORESITE <br /> +—J R.O.W. LQ <br /> Q I �, DRIVEWAY r ForesM1eGroup,lnc. group <br /> 3000 E Cesar Chavez St. <br /> L S.1.4. <br /> ,X]6]02 66].6024 <br /> + 8+QQ <br /> �// � 1334.66].6064 <br /> z E.O.P — — — — — — w <br /> _z <br /> J —J <br /> E.O.P = <br /> d GAS STA: 8+29 c- <br /> — GAS - BOREPIT/ INSTALL (1) Q <br /> 75; I 36"x 60"x 36"VAULT � <br /> C.L. — — — _ — COLBY AVENUE <br /> 3 — — — -C.L. <br /> ENGINEER: AS <br /> YV_ AAT DRAWN BY: AS <br /> w REVISIONS <br /> /YJ n^TF DESCRIPTION INITIAL <br /> E.O.P NOTE TO CONTRACTOR: <br /> ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> E.O.P TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> _ <br /> - - CAUTION!! <br /> R.O.W. ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> ADC RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> R.O.f ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> V V SPECIFICATIONS. <br /> 4630 COLBY AVE \ / ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> 1 FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> 4634 COLBY AVE ACCURATE OR COMPLETE. EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> U THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> I / CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 PROPERTY OF MCI COMMUNICATIONS SERVICES,INC..BOT <br /> BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT B <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO REPRODUCED, COPIED, OR USED FOR ANY PURPOSE <br /> MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMISSION. <br /> DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> I UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> I I LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> WITHIN CONSTRUCTION PATH. <br /> ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-04 <br />