My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1610 106TH PL SW A,B 2024-11-08
>
Address Records
>
106TH PL SW
>
1610
>
1610 106TH PL SW A,B 2024-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2024 11:55:56 AM
Creation date
10/14/2024 11:26:33 AM
Metadata
Fields
Template:
Address Document
Street Name
106TH PL SW
Street Number
1610
Unit
A,B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Field', <br /> Report <br /> LeNY,g Mwb"h"rg y 8N b yMw aM aaR <br /> IT-10" 10'-8" 6'-6" 6'-6" 10'-8" 12'-10" Pm9M1t20s3 Field R"P 030Pa Fiala R"Port <br /> 6'-8" 6'-2' 3'-4" <br /> GENERAL NOTES <br /> 1. ALL EXTERIOR WARM WALLS TO BE 2x5 STUDS <br /> 3'-4" 6'-2" 6W 16"O.C.TYPICAL,WITH R-21 INSULATION. <br /> 2.ALL HEADERS ON UPPER FLOOR TO BE 4.8 <br /> 4020XOSDR. 6040 SLDR - DOUGLAS FUR#2 UNLESS NOTED OTHERWISE. <br /> `o <br /> EG 3.FUR-0UT HEADERS TO MATCH 2.6 WALLS. <br /> 6040 XOS R. 4020 SLDR ——P8S HWR' ( S) 4.PROVIDE SOLID BLOCKING UNDER ALL <br /> (EGR S) R P8S +72" o SOAK NB BEARING WALLS. <br /> 5.INLINE FRAMING-SINGLE TOP PLATE STRAP <br /> R P G @ SPLICES AND CORNERS,EXCEPT AS NOTED <br /> W.I.C. ❑FANO WO VAULTED CLG. FORSHEARTRANSFER. <br /> SOAKTUB +72" ---CPT-- HIP ROOF gi O <br /> �CFM N 8.ALL GUARDRAILS PER MANUFACTURERS <br /> MASTER 2a6e <br /> FAN W.I.0 BATH SPECIFICATIONS.SUPPORTS CAPABLE OF <br /> N NO VAULTED CL 5❑VToFFM ZP� 2a 68 �Y� O RESISTING SINGLE CONCENTRATED LOAD <br /> N WITH HIP ROOF OF 200 POUNDS,APPLIED IN ANY DIRECTION <br /> 2 6 MASTER m it 3'-4' 7'-4" MASTER AT ANY POINT ALONG THE TOP OF THE RAIL <br /> BATH <br /> Q —VBTpI- 246s BED M 7.TUB/SHOWER UNITS SHALL HAVE FIRE BLOCKING <br /> BETWEEN WALL STUDS AND WATERPROOF <br /> M T-4" 3'-4" i _ O o, BURROI NDS IN OW FROM DRAIN.GLAZING, <br /> BEDARS OM INCLUDING WINDOWS WITHIN+72" IS DRAIN,SHALL <br /> SLOPE SLOPE BESAFETY GLASS.SHOWER FLOW IS LIMITED TO <br /> o A <br /> '� 2.5 GAL/MIN.WOOD FRAMING TO BE PROTECTED <br /> o _P —y — ELECTRIC FROM WATER SPLASH AND MOISTURE. <br /> SLOPE SLOPE � O WASH FURNACE <br /> 8.ALL BATHROOM FANS,KITCHEN HOODS,AND DRYER <br /> ELECTRIC In" "In <br /> " O SHALLBEEXHAUSTED THE ATTIC T THE <br /> ROOF <br /> y .o ROOFF OR THRU THE FLOOR SYSTEM TO AN OUTSIDE <br /> FURNACE �O <br /> WASH W.H.FAN LAUNDRY '0 60" J WALL ALL WALL DUCTS SHALL TERMINATE AT LEAST <br /> e ❑VTO �IN4L 36"FROM A WINDOW OPENING. <br /> m _ 75 CFM RO:5'0-V4" <br /> zo <br /> L N 9.ONE WINDOW PER BEDROOM SHALL MEET <br /> c - TUB ShN1�R LAUNDRY ❑vrO FAH N o EGRESS CODE PER 2078 IRC R310.1 <br /> R.OP5'0-1f4" 75 CFM <br /> o LOUVE OON (2 76 (2J#CS16 10.UNDER ALL PARALLEL BEARING WALLS,USE DOUBLE <br /> 0 <br /> JOISTS OR AS NOTED ON PLAN,DOUBLE JOISTS <br /> DOOR OR O ❑FAN UNDER ALL NON-BEARING PARALLEL WALLS. <br /> FANo AIR FL W 50 CFM 11.WHOLE HOUSE INDOOR VENTILATION SYSTEM WITH <br /> �' <br /> ..,r(2)#C516 "� (2 S16 ❑CFM <br /> O. i LOUV R ON BATH <br /> ` SO CFM i. DOOR OR —VINYL - 24 HOUR PROGRAMMABLE TIMER.RETURN AIR <br /> AIR FL W 1` ZE y TO BE SUPPLIED BY HEATING SYSTEM. <br /> BATH <br /> � A8 LOFT J Ro '& 12.MAX.HOT WATER TEMP.DISCHARGING INTO A U-1 <br /> Q BATHTUB OR WHIRLPOOL BATH SHALL BE LIMITED KLP HOMES <br /> ti W i TO 120'F.THE WATER HEATER SHALL NOT BE <br /> o ti z^ CONSIDERED A CONTROL FOR MEETING THIS PROVISION. <br /> 0 0 0 LOFT <br /> CPT 11'-10" OO 13.ALL OPENINGS MADE IN WALLS,FLOORS,OR CEILINGS <br /> FOR THE PASSAGE OF PIPES,STRAINER PLATES ON - <br /> _ DRAIN INLETS,AND METER BOXES SHALL MEET THE <br /> REQUIREMENTS OF THE 2018 UPC SECTION 313.12 <br /> 14.ALL FLASHING TO BE IN COMPLIANCE WITH <br /> 20181RC,SECTION R703.4. <br /> 6-7v P8S P8S LEGEND: P jmN^ <br /> - —— .o o IC22pT�D3��II _ <br /> `ACCESS <br /> - �NS&WSJ --- --- BEARING WALL <br /> P8S A7T�0'7i ) P8$ 5�6a Q 5068 ___ __ <br /> -- BI-PASS BI-PASS SMOKE DETECTOR 110V <br /> 3 _ INTERCONNECTED W/BATTERY <br /> BACK-UP <br /> m 81-PASS ® ® " BFPO$ -- O b- CARBON MONOXIDE DETECTOR 110V <br /> 7'-4" 3'-6" 8'-31/2" 7'-0" ___ ___ INTERCONNECTED BATTERY <br /> -- - BACK-UP PER IRC315 <br /> ---w` (S.G.) SAFETY GLASS <br /> BED#3 - BED#2 VTO VENT TO OUTSIDE <br /> --- --- BED#2 cFr— 4 CPT ------- ❑ FAN-VENT TO OUTSIDE <br /> --- --- 50 CFM MINIMUM <br /> BED#3 <br /> CFr ----- SHEAR NOTE: <br /> --------_--- WALL LINE BELOW SEEING SC E FOR SHEARDETAILS <br /> NAILING SCHEDULE 8 DETAILS <br /> ------- WALL UNE BELOW (EGRESS) (EGRESS) , <br /> 4060 0SLDR 4050 SLDR. FOYER BELOW <br /> (EGRESS) (EGRESS) - - <br /> �OPEN TO- <br /> F9YflF BECOIK 4050 O SLDR 4050 0 SLDR ' <br /> ti <br /> 3050 FXD. 3050 DID. - ROOFVENTNATION CALCULATION - <br /> 2,852 SF <br /> 3060 FXD. 3050 FXD. VEr.f11UTON REWIRED 17.68SF/2,546SQ.IN.(1/150PERR8D6.2) - <br /> G.C.TO PROVIDE A MINIMUM OF 17.68 SF FREE REA OF VENTING IN <br /> 3'-II" 3'-6" S-11" 3'-10" T-10" 5'-5" 5'-6" V-6" 5'-5" V-10" 3'-10" 4'-0" 3'1" COMPUANCE WITH R806.1 -� - <br /> F�IN <br /> ROVIDE BREAK DOWN CALCULATION FOR <br /> T-e^ o'-n" 10'-»" r-B" 7'-7 a'ao" SPECTION <br /> HOW MUCH BIRD BLOCK?HOW MUCH RIDGE <br /> VENT?ETC.. <br /> R,y.nx.a • <br /> ' UPPER FLOOR PLAN <br /> SCALE: V4"=T-W <br /> sal. <br /> 114„=T-0„ <br /> sl.a Nam" <br /> UPPER FLOOR PLAN <br /> A5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.