Laserfiche WebLink
GABLEOVERHANG FIRE PROTECTION <br /> SCALE: $«T V-0° <br /> FOR BUILDINGS EQUIPPED WITH FIRE <br /> SPRINKLERS EAVE VENTS ARE ALLOWED <br /> WHEN DISTANCE TO PROPERTY LAVE IS' <br /> OPTION 2;CONTINUOUS COR-A-VENT 3t-0`OR GREATER PER IRC TABLE 302,1(2) <br /> OR EQ.%-VENT"36"MIN UP FROM <br /> DRIP LINE,INSTALL PER'MFG SPECS <br /> OPTION 1.50 SQ.IN.ROOF VENT 5'-0" MIN. FIRE SEPARATION DISTANCE <br /> SPACED EVENLY ALONG EAVE.NUMBER LESS THAN 61-0" <br /> PER ATTIC VENTILATION CA C$ 2'-0 MIN <br /> SOLID 2x FIRE BLOCK. <br /> NO HOLE'S ALLOWED <br /> f� <br /> "CCX PLYWOOD o <br /> @ EAVES <br /> LLj <br /> WIND BAFFLE TO EXTEND BEYOND I� <br /> CHOSEN VENTING M(THOD <br /> PER PLAN <br /> O <br /> a.. <br /> WA STATE AMENDMENTS TABLE 4302.1 <br /> FOOTNO T E.ROOF EAVE FIRE-RESISTANCE <br /> RATING SHALL BE PERMITTED TO BE <br /> REDUCED TO 0 HRS ON TIDE UNDERSIDE OF <br /> THE EAVE IF FIRE BLK'G 1$PROVIDED FROM <br /> THE WALLTOP PLATE TO THE UNDERSIDE <br /> OF THE ROOF SHVG <br /> EAVE FIR <br /> /� SCALE: ,,�=V-0" <br />