Laserfiche WebLink
TYP.EXTERIOR WALL ASSEMBLY <br /> I <br /> 12 <br /> 5�- <br /> MFD.TRUSSES MFD.TRUSSES - <br /> PER PLAN PER PLAN <br /> R-09 R-49 <br /> 2X4 FRAMING W/ INSULATION jj4 <br /> NSULATION <br /> R13 INSULATION <br /> .TWwpe,R.eew <br /> UPPER TOP PL 2.512 <br /> L_ <br /> - - - - aWlv.=.I..x.Mr+waN.�.M.wx- <br /> T AIR SPACE <br /> N HIP <br /> ATION _ _ N HIP EL VAUC G* C pOgHt-3 Fi-Report C W23 Reid R-1 <br /> - - MA ER <br /> PARTY WALL PLAN DETAIL �� BED M BATH LAUNDRY Ae LAUNDRY BATH BED M <br /> VINYL W- VINYL VINYL <br /> 1/2'G.W.B.®WALLS - - - - 12'G.W.B.Q WALLS <br /> G�LUEJ. - <br /> D.SUB FLR T&G PLYWD.SU FLR. <br /> CREWED GLUED B SCRE ED <br /> SHEATHING APPLICATIONS TO COMPLY UPPER SUB FLR. - - - Li <br /> - <br /> WITH IRC 302.2.3 FL JST. ER <br /> MAIN TOP PL LR. T.P R P N <br /> CONTINUITY MUST BE PROVIDED <br /> THROUGH THE FLOOR/CEILING <br /> ASSEMBLIES AND TO THE OUTSIDE 5/8' .B. 5/8'G. B. <br /> EDGE OF UPPER STORIES IN <br /> ACCORDANCE WITH R302.1 CL D NG BEYON DI NG BEYON @ CLG. I O <br /> I I I I I I I I I <br /> b o T KITCHEN I KITCHEN O II <br /> CP FOVID HOWL CPT II X <br /> R-21 INS.� R-21 1NS� <br /> EXTERIOR ALL EXTERI ALLS <br /> GLLGIEO&SCREWED R. R-381NS. R-381NS. GLUED 6 SCREWED <br /> MAIN B FLR. � UA <br /> LR. ST. R P N LR. T. R <br /> I <br /> CRA L SPAC'AC CF2A L SPACE -II <br /> PER 201 IRC SEC.R40B2 PER 20181 SEC.R408.2 <br /> CLASS 1 IL.POLVETFN' E CIASS 1 6 POLVETHYLEN - <br /> 1I I I I I I BARRI OP OF FTG BARRIER OF FTG. <br /> I I I I I I I I I I I I I w/12 P ALL sEAMs wi 12 SEAMS <br /> PRE.MFD.TRUSSES 1 LAYER FIRE TED GWB <br /> TRUSSEPER S@24"O.C. E OTRUSSS ARTY WALL <br /> SECTION A-A <br /> R-491NSUL. II I I II I I II /�'`� '� �ti _s SEE GENERAL NOTES SCALE:1/4"=1'-O" Q <br /> I I I I I I I I I I I I I MFD.TRUSSES 1 W <br /> PER PLAN <br /> ry3� KLP HOMES <br /> r`K / DUCT AND AIR TRANSFER i.1' �•/ ,pWal <br /> OPENINGS IN HORIZONTAL pl `'F J ®CEILINGG.W.B. <br /> DOUBLE 2X BLOCKING ASSEMBLIES SHALL COMPLY <br /> AT UPPER FLOOR PLATE <br /> 2X OVER AIR GAP FOR DRAFT STOP WITH R3024 USING R3022,ITEM 3 2z DOUBLE TOP PLATES <br /> 2018 WASHINGTON STATE ENERGY CODE <br /> -1-AIRSPACE SPACE <br /> BETWEEN WALLS DW INGUNITSIN TWO-FAMILY DWELLINGS SHALL BE <br /> SEP TED FROM EACH OTHER BY WALL AND FLOOR 'CLIMATE ZONE 5&MARINE 4' <br /> _ y AS SUES HAVING NOT LESS THAN A 1-HOUR FIRE- <br /> R-13 INSULATION . & .k RES ANCE RATING WHERE TESTED IN ACCORDANCE WITH <br /> AS El 19.UL 263 OR SECT ION 703.3 OF THE INTERNATIONAL FENESTRAION SKYLIGHT DOOR CEILING ABOVE GRADE BELOW GRADE FLOOR SLAB R-VAUUE <br /> BUIL NG CODE. EXTERIOR SIDE COVERED WITH U-FACTOR SKYLIGHT_FACTOR <br /> U-FACTOR R-VALUE WALL R-VAL(UE WALL R-VALUE R-VALUE AND DEPTH <br /> 2z4 WALL®18'O.C. <br /> EXCE ON:A IN BUILDINGS EQUIPPED <br /> RATING OF 12 HOUR SHALL WOOD STRUCTURAL PANELS,APPLIED <br /> SHEAR WALL PER PLAN; BE OMATI IN BUILDINGS EQUIPPED THROUGHOUT WITH VERTICALLY WITH EDGES OVER R-49 <br /> NAIL PER PLANS:SEE AN TOMATIC SPRINKLER SYSTEM INSTALLED IN FRAMING OR BLOCKING AND FASTENED 0.30 0.50 0.30 (R-36VAULTED) R-21 R-10 RJO R-10.2 FT. <br /> SHEAR WALL SCHEDULE. ACC ANCE WITH NFPA 13D. WITH 6D COMMON NAILS(BRIGHT) <br /> BOTTOM PLATE NAILING @ 1Z'O.C.IN THE FIELD AND 6" <br /> SOLID BLOCKING AT 10'-0.O.C. PER SCHEDULE TO 2X O.C.PANEL EDGES <br /> ABLE 406.2 ENERGY CREDITS HOUSES BETWEEN1500 SF&5000 SF REQUIRE La CREDITS <br /> W/FIREPROOF CAULKING BLOCK ING EA JST.BAY <br /> TYP.0 EACH FLOOR <br /> HEATING OPTIONS CREDITS) CODE REQUIREMENTS �•� <br /> FL R JOISTS R PLAN <br /> OHEAT PUMP 1.0 POST ENERGY CODE COMPLIANCE CERTIFICATE <br /> WITHIN 3 FT.OF ELECTRICAL PANEL PER 2018 <br /> (3)lDd TOE NAIL, NAILING PER SHEAR WSEC R401.3 <br /> JOIST TO TOP PLATE WALL SCHEDULE <br /> TOP.a EACH FLOOR <br /> TYP.0 EACH FLOOR ENERGY OPTIONS CREDIT(S) PROVIDE DOOR BLOWER TEST BY FINAL <br /> 'SIMPSON'A35 CLIP smiINSPECTION PER 2018 WSEC 402.4.1.2 <br /> PENETRATIONS IN THE -@ EACH BLOCK FIR ESISTANCE-RATED FLOOR/CEIUNG AND WALL 1.3) EFFICIENT BUILDING ENVELOPE 0.5 <br /> WALL ASSEMBLY 12Ad•1"NAILS ASSOASUES SHALL EXTEND TO AND BE TIGHT AGAINST THE 216 WOOD STUDS @16-D.C. VER %NESTRATIMN ua1S PROVIDE 1 PROGRAMMABLE THERMOSTAT PER <br /> TYP.@ EACH FLOOR EXTE IOR WALL,AND WALL ASSEMBLIES SHALL EXTEND <br /> SHALL COMPLY WITH IBC FRO THE FOUNDATION TO THE UNDERSIDE OF THE ROOF uN0E8 sys R. <br /> 2018 WSEC R403.1.1 <br /> R302.4 USING R302.2, SH HING. <br /> ITEM 3). PROVIDE DUCT SEALING AFFIDAVIT BY FINAL <br /> EXC ION:WALL ASSEMBLIES NEED NOT EXTEND 3.5 1 E T V C 1 5 INSPECTION PER 2018 WSEC R403.3.3 <br /> VSHEAR WALL PER PLAN; THR OH ATTIC SPACES WHERE THE CEILING IS aB-S-CE,cEMBALLY CUCTEO xEAT PMMP, <br /> ( ( NAIL PER PLANS;SEE PRO CTED BY NOT LESS THAN WINCH(15.9 MM)TYPE X A MINIMUM OF 90%OF ALL INTERIOR LIGHTING ------ -- <br /> /` SHEAR WALL SCHEDULE. GYP M BOARD,AN ATTIC DRAFT STOP CONSTRUCTED AS MN,Hsr+F 0 110 SHALL BE OF HIGH EFFICIENCY PER 2018 WSEC <br /> ALL PENETRATIONS IN - SPE FIED IN SECTION R302.12.1 IS PROVIDED ABOVE AND 404.1 <br /> (2)1-HOUR PARTY ALON THE WALL ASSEMBLY SEPARATING THE DWELUNGS �) EFFICIENT HVAC DISTRIBUTION SYSTEM 1.0 <br /> WALL MUST BE CAULKED R-13 INSULATION AN HE STRUCTURAL FRAMING SUPPORTING THE CEILING <br /> WITH FIRE CAULK PER R302.4 IS P TECTED BY NOT LESS THAN 12-INCH(12.7 MM) H%-EWPMETRANDPBBOCUTEDDUCT <br /> USING R3022,ITEM 3 GYPS M BOARD OR EQUIVALENT. SYYSTEMs xuru F^IN caMPLw2CEwrTH wsEt <br /> 31 <br /> V AIR SPACE R-19 MINERAL FIBER INSULATION <br /> BETWEEN WALLS INSTALLED IN STUD CAVITY EFFICIENT WATER HEATING 2.0 <br /> /c) <br /> RATING ESTABLISHED FROM THE `i <br /> DOUBLE RIM JOIST 3/4"T&G PLVWD. GYPSUM-COVERED SIDE ONLY EL£CTWCHFATPUWWATWt HI TR <br /> sUB FLR.GLUED 8 SCREWED <br /> FLOOR JOISTS PER PLAN <br /> F RJOIS PER <br /> TN.IFee xa.a <br /> III=III=11 TABLE M1507.3.3(1) • <br /> 1=1 I=I I CONTINUOUS WHOLE HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS <br /> •,',., Im I II NUMBER OF BEDROOMS ------- <br /> M I IEEI DWELLING UNIT <br /> �•.: I-III FLOOR AREA 0-1 2-3 4-5 1 6-7 >7 <br /> (SQUARE FEET) <br /> AIRFLOW IN CFM <br /> �c 11,500 30 45 60 75 90 <br /> 8"F U6 NDlit10N - =-11 1,500-3,DO0 45 60 75 90 105 �M <br /> 3,001-4,500 60 75 90 105 120 SECTIONS <br /> PARTY WALL DETAIL �L �f� C( � 4,501-6,000 75 90 105 120 135 <br /> 1 SCALE:N.T.S. L SCALE:N.T.S. 6,001-7,500 90 105 120 135 150 <br /> >7,500 105 120 135 150 165 <br /> FOR S1:1 SQUARE FOOT=0.0929m 2 1 CUBIC FOOT PER MINUTE=0.0004719m/s 3 <br /> fYeLxrlr <br /> A8 <br />