Laserfiche WebLink
GRAPHIC SCALE EVERETT CHASE BANK ` City of Everett Permit Review <br /> Ev_ERE7T Status:Reviewed for Permit <br /> 0 10 20 A PORTION OF THE SE 1/4 OF THE SE 1/4 OF SECTION 30, TOWNSHIP 28 NORTH, RANGE 5 EAST, W.M. 09/13/2023 2:35:35 PM w <br /> 1INCH=10 FEET(22"04") CITY OF EVERETT, SNOHOMISH COUNTY, WASHINGTON <br /> 1 INCH=20 FEET(11"X17") STORM WATER PLAN <br /> z <br /> O <br /> 1 <br /> a <br /> CITY OF EVERETT STORMWATER <br /> DRAINAGE NOTES <br /> 1. NO PART OF THE DRAINAGE SYSTEM SHALL BE COVERED, <br /> U C - CONCEALED,OR PUT INTO USE UNTIL IT HAS BEEN INSPECTED, <br /> TESTED,AND ACCEPTED BY THE CITY OF EVERETT. <br /> 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF z <br /> F- O <br /> \� p EXISTING CB#4 EVERETT DESIGN AND CONSTRUCTION STANDARDS AND v> <br /> > <br /> c� SPECIFICATIONSAND THE W D T APWA ANDARD <br /> s o sr <br /> o / <br /> LL RIM=455.34 w <br /> TT �'}'•' TaT -•'T.T'•' .',',' 'T -----�` SPECIFICATIONS FOR ROAD BRIDGE AND MUNICIPAL <br /> ,r,-I••� ^h '{:•'•"� IE 12"0=447.99(N) <br /> \ I - - .','.'.'•'•','.''',',','.'•'•',','.'.','.'.'.'•'•',',L' T',r•', ,'I '\\ IE 12"0=447.93(W) CONSTRUCTION(CURRENT EDITION). U(A M <br /> M <br /> \ IE 12"4=447.91 E LU E co <br /> 1 - , ,••. ---'• d--P - `P \ \ �\\\ \\\: ��\\\ \\\\\\\ \\\j_ \\\\\\\ \\\\\\ p UJ - O 3. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN J W o o, <br /> N \\ \ \ \,, \� \\ \ c7 I OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR Z <br /> A A U <br /> Z- <br /> ✓� A\\ � AV AV AV AV A\� \V A A\� AV• AV.� '�.',','� CONVENIENCE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br /> _ uG -I UC yy:. vw yvyyy: vyyv vvv v yvyv �yvv, 'vyy� ;,I ,� , <br /> I - SDCB#4 TYPE 1 - AV -- A \\\� ` V `V A V A\\�� _�A�� A\A�' 27 LF 2"D ADS N-12 @ 0.70% VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO ANY o M� <br /> \V A\ V A AV A'V-- __ A\ ?y, \ _ A , .J �.l.- - ADDITIONAL UTILITIES SHOWN.IF CONFLICTS WITH EXISTING c rn <br /> RIM=455.17±ME A Av A\V A A\V. AV A A V A\� 1'-'•',,,,,','•'• ,', 'QI o m <br /> -�--- 1 a IE 10'Ck451.01(N) TO REMAIN) \ -- -- A\ -AV A\V A A\ - \ � f. Q2. ',', UTILITIES ARISE DURING CONSTRUCTION,THE CONTRACTOR Z Q 2 <br /> m IE 10"0=451.01(S)(TO REMAIN)_-P ___ AAA \\�AV. VAV V A- A SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY CHANGES o - <br /> -L EXISTINGCB#1 -Z �w CO <br /> U Q -\� ����A\��A ��A\�AV �A���AV A����� A��A\ A�� RIM=454.SOt ME •�: REQUIRED SHALL BE APPROVED BY THE CCTV ENGINEER PRIOR TO a o <br /> 1 c� IE 10"❑=451.01(W)(NEW) ' <br /> 1 OVER <br /> CB ON EXISTING PIPE \\\�A\V`A\�A\\VA\�\\\�AV�\\VA \�A\\�A VA\\V AV� IE 4"0=452.18(N) ,'.,, �, p COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. <br /> �\VA\VA\��A\\\A\VA\\�A\\�A\VA\\\A\VA\VA\� OS. IE 30 Ck451.37(N)(TO REMAIN) a,��•ra I .'I 4. ALL STORM SYSTEMS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN <br /> I I A AV AV A AV AV AV ,�\> A fl� \ IE 10"�451.37 W N EASEMENTS MUST BE STAKED BY SURVEY FOR LINE AND GRADE OC , <br /> -� EXISTING 56 LF 10"❑ADS N-12 @ 0.55% -- __ _. \V AV A� A'v�q`V A\�\V A \V A ( )( EXISTING CB#3 0(.7 <br /> �. G - - 1 \�:�15- \�V A�\\VA\ � \\V AV A\V V AV A� I \A\V '.RIM-455.37 O rn <br /> Oct._ _ag- - A AV A\V A� \\� I, A\\V\ PRIOR TO STARTING CONSTRUCTION. y,J <br /> -ag=.- -05 9S �.�\� AV�\\\VA\VA\\V AV AV AV \VA\\�A\�A\ \�A\\VA\ '•IE 12'0=448.14(W) I <br /> AV A AV A AV A AV A V A A \ 5. ALL CATCH BASIN GRATES MUST BE STENCILED OR STAMPED O1 Z <br /> AV\ \V AVA \V AVA VA v�il�� AV AVA "DUMP RAINS TO STREAM. <br /> V A V A V A V A V A AV - '. .']E 12'0-448.12(E) W�� x i, <br /> V A V A V A V A V A \ <br /> EXISTING CB#6� - Iol 18 LF 12"PJ ADS N-12 @ 5.21%V AV A\V A\VA\V A\VA\V A\VA\V A\VA\� l\VA\\VA\VA\\V AV A\ ', .',','� I WASTE,D �ry <br /> RIM=455.07(EG).. v L I h VA\VA\\VA\\VA\VA\\VA\\VA\V�\\VA�VAV AVA\\VAV��\�VA\\\ I�AAV A\VA�\\�AV A�. <br /> A AV A \ \ \ V \ \ V A V A 1 <br /> IE10"Ck451.87(SW)(TO BE REMOVED) bsI I I '\\�A\\�A\�A\\�A\�A\\�A\VAS\�A\\�A\VA\\VA\VAA LAVA AAA�A ��A\VA LAVA\VA�A A\\\ 0.. I �- dt <br /> IE 10 Ck451.42(N)(TO REMAIN). A7nIAVA\VAV <br /> IE 10�450.70(5)(TO REMAIN) - ` SDCB#3,TYPE 1 \\\VA\\A\\VA\\VA�\*!\�\VA\�\\\�A\\VA\VA\\��I��A\VA\VA\\A. A \\ - �':' I POTHOLE NOTE �O <br /> I I �V A AV A \ \ V A V A V A AV ' <br /> IE 12'Ck450.55(E)(TO REMAIN) c� I I�I RIM=454.96f MEA\\V\V�, _ ALL PROPOSED UTILITY CROSSINGS MUST BE POTHOLED PRIOR TO <br /> �I Ili IE 12"'E451.96(E)\VA\\V � \�A\�VA\V AND NOTIFYCONSTRUCT PROJECT ENGINEER OF ANYN. SUPPLY POTHOLING MPO ENTIAL CONFLICTSATION TO PROJECT GINEER, LU <br /> ZLu <br /> Zc u�i <br /> ri <br /> - v i a DISCOVERED. W <br /> \ I \ \\' \\ \\ \ \ � '•' <br /> POTHOLE REQUIRED PRIO LU -J t � <br /> I a I S� l Ski i f v a <br /> �rsrsx �' <br /> o 2023.09.06 <br /> ROOF DRAIN STUB OUT - <br /> 1 l a I CAP AND MARK - <br /> o o - LOCATION DENOTINGA\�A\�A\\�A\ I l :•'•�. , I �- 9 <br /> oIa l I STORM CONNECTION J' \ SDiCB#2 TYPE 54 LF 0"❑ADS N-12Q0i/"V RIM=455 30t MED JL D IE 10"11k451.88 '''•"',QOi..+'''I+. <br /> I' <br /> -I•'.''.' o <br /> (N) LLl <br /> ----- <br /> 1. e. AVA\V� [E 10"Ck451.88(E) a a....� Z o O <br /> SDCB#1,TYPE A�V� tf, A VAS\A\ VAV,�A\ VA / I r, <br /> 1 RIM=455.27 AVA\\\� " .A VA\\�AV\\\V\�VAV -o Q - Q M 2 <br /> IE6"�as2.6Dvv�Vy °s jy ,wv���yvv vvv yvvvvv\ � ° I <br /> it> ,i IE 10'Ck452.27(S� p \\\\\\\\ \ \ \\ .' .Q: , �`�-' Qr"' <br /> IE10"❑ 452.27(S) , 456 !,c AV AV A\ ,✓..'-. ,'.' !' ' H <br /> T - - OVERBUILD CB ON EXISTING PIPE_ - - <br /> REMOVE NE PIPE RUN _P <br /> JI ) 1 I I O CONTRACTOR TO POTHOLE \ d I `Ip W a c W <br /> I I l LOCATION AND DEPTH PRIOR TO \ r2 I H I{ W vCONSTRUCTION AND PROVI ¢J Y <br /> INFORMATION TO PROJECT DE Os� 00 <br /> 09 Z¢ Q <br /> ENGINEER. _ \ U U <br /> �, \ \ EXISTING CB#5 I o w <br /> l I- os E 6 05.30(E(W) \ a l I VERIFICATION NOTE iL Q <br /> ALL EXISTING UTILITIES IN THE CONSTRUCTION AREA SHALL BE ~ ~ <br /> IE 10"11k452.31(SW) I 3 I I IDENTIFIED AND VERIFIED FOR DEPTH AND LOCATION PRIOR TO ANY F- <br /> 3 ,S, N. J 1 �( IE 10"Ck452.31(NE) V CONSTRUCTION ACTIVITIES SO TO IDENTIFY ANY POTENTIAL CONFLICTS W Z Z <br /> S-I� I `\ rr jr I a \ \\\ LU <br /> WITH PROPOSED CONSTRUCTION.CONTACT PROJECT ENGINEER = O <br /> \ ' IMMEDIATELY IF ANY CONFLICTS ARE IDENTIFIED. U U U <br /> a -3 l PRIOR TO ANY CONSTRUCTION ACTIVITIES,VERIFY EXISTING DESIGNER: K.MAUREN <br /> TOPOGRAPHY IS CONSISTENT WITH WHAT IS SHOWN ON PLANS AND IF ENGINEER: B.ALLEN <br /> THERE ARE ANY POTENTIAL CONFLICTS WITH PROPOSED CONSTRUCTION DRAWN: L.BESLER <br /> ACTIVITIES. CONTACT PROJECT ENGINEER IMMEDIATELY IF ANY S30 T28 N R05E WM <br /> CONFLICTS ARE IDENTIFIED. DATE: 2023.09.06 <br /> REVISED: <br /> PROJECT: 22-281 <br /> CALL 811 AT LEAST 48 DWG NAME: 22-281-C <br /> SHEET REV. <br /> HOURS BEFORE YOU DIG C6 6 OF 10 0 0 <br />