Laserfiche WebLink
GRAPHIC SCALE EVERETT CHASE BANK ` City of Everett Permit Review <br /> Ev_ERE7T Status:Reviewed for Permit <br /> 0 10 20 A PORTION OF THE SE 1/4 OF THE SE 1/4 OF SECTION 30, TOWNSHIP 28 NORTH, RANGE 5 EAST, W.M. 09/13/2023 2:35:43 PM w <br /> 1INCH=10 FEET(22"04") CITY OF EVERETT, SNOHOMISH COUNTY, WASHINGTON CITY OF EVERETT WATER NOTES <br /> 1 INCH=20 FEET(11"X17") UTILITY PLAN A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS <br /> OF AN APPROVED BACKFLOW PREVENTION DEVICE PRIOR TO SATISFACTORY <br /> FLUSHING,TESTING,DISINFECTION,AND RECEIPT OF SATISFACTORY <br /> BACTERIOLOGICAL TEST RESULTS. z <br /> B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE PUBLIC 0 <br /> WORKS DEPARTMENT AT THE DEVELOPER'S EXPENSE.THE PUBLIC WORKS d <br /> UC Y I DEPARTMENT SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS NOTICE FOR EACH <br /> U C-w--t- o <br /> N - -- CONNECTION.THE PUBLIC WORKS DEPARTMENT SHALL THEREAFTER DETERMINE w <br /> EXISTING HYDRANT I / THE DATE AND TIME AT WHICH THE CONNECTION SHALL BE MADE. <br /> (D C. ALL WORK AND MATERIALS MUST CONFORM TO CCTV OF EVERETT STANDARDS <br /> \ _ —I • D. A PRE-CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE <br /> _ EXISTING SSMH I1 - - \� D I START OF CONSTRUCTION.THE CITY OF EVERETT PUBLIC WORKS CONSTRUCTION <br /> I - _ _ <br /> U <br /> LL N: RIM=455.76 �'-•'jam'����"'°'•�•^�-^^ 7. �. DIVISION MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF z <br /> �� *BOLTS STRIPPED , •'�•r., �,n•T' k;.:. \. CONSTRUCTION. <br /> cn UNABLE TO OPEN •� J,•,•. .'.',..•� .� <br /> J \ \ \ \..' ' , m a E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SHALL NOTIFY THE w <br /> . , , , <br /> I — — — — - — P � \ \( \ \\\\\ \\ \\\ \\ . ':':,I1I,' •• ' p U7 a I PUBLIC WORKS DEPARTMENT OF A PERSON WHO CAN BE CONTACTED REGARDING <br /> - •, P — �\\ ,\\ a \� \\ \ \ \ \ \ '•'l'•'.I'.'.',' PROBLEMS DURING CONSTRUCTION ON A 24 HOUR BASIS. U(n M <br /> 0 \\.\ \ \\\\ \\\ \ \\ , M <br /> \ \\�\ \\\�� \\\• .\\\\ •' •�'.' ' F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 181NCHE5 VERTICAL £ co <br /> J w g rn <br /> - \ J D SEPARATION BETWEEN POTABLE AND NON-POTABLE CONVEYANCE SYSTEMS. Z a <br /> -�-- J�� ,'0�/.' A\�°v \�AV D� �� A\\V 9 ''•' •I G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC WORKS J <br /> NC \\ UC '.Q ' 1 \/ S DEPARTMENT PERSONNEL ONLY.ALL VALVES,NEW AND EXISTING,SHALL BE m <br /> I m _ <vv � v�P — vv v �� — — t7 V 0-8 2.8 <br /> R P — d— \ VA\vA\�VAV A\� \V,. a '�.'.L•u�•,'.'.'.,�,•°C=�'I•{ "9 ACCESSIBLE AT ALL TIMES. rn <br /> H FFF I P �. \ \\\\\\ \\\ \\\\\\\ \\\ \\\\\ L �•.�. U) Z"a <br /> EXISTING ICB� \V AV AV A\ AV AV AV A A \�'Qs. �• , , , . <br /> I I` o 1� `yvwv w�yv CITY OF EVERETT SANITARY SEWER NOTES z z- - - - — A V I J z o <br /> J -—as---- �� v v <br /> as- yv A AV AV A AV AV A AV AV A v vv A AV 7 o rn. <br /> I. 4 -.-- AvV AV AV AV AV AV AV A V Ay - ' ' •'•' A. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT {� v <br /> cis -as— <br /> STANDARDS\�V��V�\\VA\\\\\V A\VA\\VA�V��AVA\\VA\VAS VA\\\A\V�\\V I�I,\\VA\\VA\\V ,•,•,•,•a�• :{ STANDARDS AND WSDOT/APWA STANDARD SPECIFICATIONS. OC L7 <br /> v IAVAVA\�A���A\�A\��A\��A\�A\��A��A\LAVA\�A\��\\�A\\�A` I �A\\�A\��A\�A\�AV A\\V •I• S B. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED,CONCEALED OR W}I <br /> I IvVAv��\yyVAyVAyyAvyVA\VAv��Ayy�AvVA\y�AvV�`�yV�vVAS y� I I y�A���Ay�Ayy�A�A�vA�AyV I •,••a•,'• {� C PUT INTO USE UNTIL IT HAS BEEN TESTED,INSPECTED,AND APPROVED BY THE W x y <br /> CITY INSPECTOR. LL, ^ obi <br /> L �II I ��AVA��y�vy��Ayy��Ay�v�vy�v vVA����vyyVvyy��A� o A��AV�vy�vvVA yV ,�Ay C. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM X <br /> Z Ci in <br /> AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE.THE CONTRACTOR m�a t <br /> I I IvAyAy��AyAvyAvVAvyAvyvvy�vvyvvvVAvv�AvVAvvVAvVAvV IvVAvVAvv�AvvVvV AV.a �Ay ,• I SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID Z <br /> L AVA\\VAA �A \\\�� Iv`�A\VAVA �A\. •,CS.'. .'.I'.'I DAMAGE TO ANY ADDITIONAL UTILITIES NOT SHOW.IF CONFLICTS WITH <br /> I A v V A y A V A A y y <br /> ,, ... ;a .,,, \ \ \\ \\ \\\\�\\\\\\I o I\\\\\\\\\\\ \\\\ '. EXISTING UTILITIES ARISE DURING CONSTRUCTION,THE CONTRACTOR SHALL <br /> I h 2 LF 2"GAS SERVICE LINE \\��\\�\\\�y v���\\�\\\�\\\\\\ \ \ \ f•:• •;a.; a NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY CHANGES REQUIRED SHALL BE Lu <br /> I a. CONTRACTOR <br /> W1TH GAS PURVEYOR RDINATE °° - � �AI �A�AVA\��A� ;.' APPROVED BY THE CITY ENGINEER PRIOR TO COMMENCEMENT OF RELATED Z_M c v <br /> .i \\\..\\\ \\\\\\\\\\\ 'F�•'•�.' I CONSTRUCTION ON THE PROJECT. W C9 N F v <br /> EXISTING WATER MAIN GAS SERVICE STUB OUT D. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN Z Qj Q <br /> \ LOCATION APPROXIMATE,SEE VERIFICATION NOTE a- CAP AND MARK LOCATION I I �. EASEMENTS MUST BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR TO LLJ o u <br /> C� I DENOTING GAS CONNECTION I I I $° a-- STARTING CONSTRUCTION. a L <br /> I a REROUTE EXISTING UNDERGROUND POWER AND I I - ^� L'•, o_ <br /> I I GAS LINES AROUND NEW BUILDING LOCATION. I I Q I,h , U <br /> \ I CONTRACTOR TO COORDINATE WITH <br /> \ PURVEYORS. I °� I N I < a •4:••• •I <br /> 3 \ I I <br /> \ I c� \\\\\\\\\ I I k'•'•'• S <br /> I. I I <br /> vv vwvvw �I :':'I';': : MATCH LINE THIS SHEET <br /> WATER SERVICE STUB OUT V / <br /> i CAP AND MARK LOCATION I � .�\�A\\�\\V� T I I � � -Q �,'.' � � M m M � �� M M M M M <br /> DENOTING WATER CONNECTION ,I .I �','.'I'.I <br /> EXISTING WATER MAIN oi, R�tceo �W <br /> �s <br /> -, _ ----- LOCATION APPROXIMATE,SEE VERIFICATION NOTE SI Orna <br /> a I SEWER SERVICE STUB OUT v\VA\VA\\\� I I P I I I�I 2023.09.06 <br /> I V I O CAP AND MARK LOCATION - 1I r, I - <br /> I \. I � ' DENOTING SEWER CONNECTION -�i{'S I I P / I `• •' I I U7 I I O u7 <br /> ' - - _ v, 00 <br /> I _ /123 LF h"POLY WATER SERVICE LINE <br /> �L--- \\\\\\\ \\\\ —SD—SD—SD— SD - SD -- S �— � I� I <br /> / .. <br /> -� 5--- SSCO W/TRAFFIC RATED LID , .'.' c� - L I-11 co <br /> SIDE SEWER CONNECTION —' RIM=455.70 ° \\\\�\ \\\\� \ =ice ELECTRICAL SERVICE STUB 5.0'INSIDE PROPERTY LINEI1•••,.,A - <br /> TO EXISTINGE 6"Ck451 07±(S I I BI TJ --� IE 6'Ck451.75(E,NW) ° a<\\\\�\��\����\\\ \\��\\�\\��\��\\�\�� , s o CONTRACTOR TO COORDINATE WITH POWER PURVEYOR, '•a�'4' _ JI SEE TER METER _ _ Y Z <br /> IE 8"0=450.90t(W�E) I I _ ,. V AV AV A \ �\\\\\V�\\VAA\\�Ay��,��� CAP AND MARK LOCATION DENOTING POWER CONNECTION .,�:.71,�;, SEE DETAIL 1,SHEET C10 M z o 0 <br /> • - __ _❑ �,�,•, \\\�\\ ,'\ \�\\\\\�. '�,� — \•�' 9 LF 41 POLY WATER SERVICE LINE o0 w 0_ <br /> UJ <br /> - _ P�--�♦ - - - - - , _�'. , ,'.'.'.',', .,1. .,,�, SEOE DE AILNN O I,SHEET CION TO G WATER MAIN z Q N <br /> 34 LF 6"❑PVC SDR-35 @2.0% I ��. L. /_P. _ \ <br /> O. P \ - - - d IXISITNG HYDRANT I I j Y <br /> w O \ Os as <br /> EXI <br /> s - STING TRANSFORMER P LU a o W <br /> W o m <br /> 123 LF 1}"POLY WATER SERVICE LINE OS Z Q <br /> D N O C I <br /> N Il i t POTHOLE NOTE Q a <br /> 1 I I ".Lfj ALL PROPOSED UTILITY CROSSINGS MUST BE POTHOLED PRIOR TO VERIFICATION NOTE F_ N LL <br /> CONSTRUCTION. SUPPLY POTHOLING INFORMATION TO PROJECT ENGINEER, ALL EXISTING UTILITIES IN THE CONSTRUCTION AREA SHALL BE L)J/ \ / I a J \ \\ AND NOTIFY THE PROJECT ENGINEER OF ANY POTENTIAL CONFLICTS a <br /> EXISTING SSMH 10 L I 1 IDENTIFIED AND VERIFIED FOR DEPTH AND LOCATION PRIOR TO ANY F_I CONSTRUCTION ACTIVITIES SO TO IDENTIFY ANY POTENTIAL CONFLICTS W Z Z <br /> �LADDER 56.46 /�I - DISCOVERED. WITH PROPOSED CONSTRUCTION.CONTACT PROJECT ENGINEER UU <br /> IE 8"❑PVC 451.11(N) 0O <br /> /-\- J z IMMEDIATELY IF ANY CONFLICTS ARE IDENTIFIED. In L) L)= — � � d. - <br /> IE 8"❑CONC=451.07(W) /� H - - - O POTHOLE REQUIRED PRIOR TO CONSTRUCQON. DESIGNER: K.MAUREN <br /> IE 8"❑PVC=451.02(NE) // [J - PRIOR TO ANY CONSTRUCTION ACTIVITIES,VERIFY EXISTING ENGINEER: B.ALLEN <br /> IE 8"❑PVC=451.02(E) <br /> // a TOPOGRAPHY IS CONSISTENT WITH WHAT IS SHOWN ON PLANS AND IF <br /> I _ O /' 9(� <br /> I O THERE ARE ANY POTENTIAL CONFLICTS WITH PROPOSED CONSTRUCTION DRAWN: L.BESLER <br /> ACTIVITIES. CONTACT PROJECT ENGINEER IMMEDIATELY IF ANY S30 T28 N R05E WM <br /> L CONFLICTS ARE IDENTIFIED. DATE: 2023.09.06 <br /> � WATER SERVICE NOTE REVISED: <br /> __ <br /> THE LOCATION OF THE WATER SERVICE LINE AND METER DEPICTED ON THE PROJECT: 22-281 <br /> `------------- o CALL 811 AT LEAST 48 DWG <br /> I � � PLANS IS A RECOMMENDATION. CONTRACTOR TO CONFIRM LOCATION OF NAME: 22-281-C <br /> 11 I M M M � WATER SERVICE LINE AND METER WITH THE CITY INSPECTOR. SHEET REV. <br /> MATCH LINE, THIS SHEET HOURS BEFORE YOU DIG C7 0 <br /> 7 OF 10 <br />