My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-01 2024-11-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-01
>
3003 W CASINO RD BLDG 45-01 2024-11-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2024 8:06:42 AM
Creation date
10/24/2024 7:50:26 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-01
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> SEE DWG 45-001-EOA, FOR LEGEND AND ABBREVIATIONS. <br /> GENERAL NOTES <br /> 1 n F r Q n 1. UNLESS OTHERWISE NOTED ALL CONDUIT IS 3/4" EMT. <br /> t V U J 2. UNLESS OTHERWISE NOTED WIRE IS STRANDED, COPPER <br /> TYPE THHN INSULATION, #12 AWG FOR POWER AND <br /> #14 FOR CONTROL. <br /> 3. THE FOLLOWING COLOR CODING OF CONDUCTOR SHALL <br /> BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. <br /> 208Y 120V 480Y 277V <br /> A � (LET BUS IN PNL) BLACK BROWN <br /> B � (CNTR BUS IN PNL) RED ORANGE <br /> z C � (RIGHT BUS IN PNL) BLUE YELLOW <br /> J NEUTRAL WHITE GRAY <br /> _ EQUIPMENT GROUND GREEN GREEN <br /> w ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> 3V01-2G2/Sa *GREEN WITH YELLOW TRACER <br /> CONTINUED LO DRAWING 1/2"C 2#10 SICK BAY 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE <br /> MATCH LINE 45-001-1E10 _ _ _ _ _ & 1#12 GND _ _ _ _ _ _ _ _ _ COLORED JACKETS SHALL BE IDENTIFIED WHEREVER <br /> SEE SHT. 1E10 VISIBLE BY APPROPRIATELY COLORED TAPE. <br /> Sal (TYP) (TYP. OF B) 5. FOR PANEL SCHEDULES SEE SPECIFICATIONS. <br /> K 31 Ill F 3V01-2G2/Sb <br /> 424 22 10c 1Uc 14 10c 14 28 1/2 C, 2#10 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION <br /> �� & 1#12 GND BOXES, SWITCHES, ETC, WITH PANEL AND CIRCUIT <br /> �8b 3V01-2G2/12a,12b,12c DESIGNATION. <br /> 3/4"C,HTI & 1#10 GND 1 50 50 7, POST NEW OR REVISED PANEL SCHEDULES IN <br /> 3 VIA LIGHTING CONTACTOR 8b 12a 10b A C ELECTRICAL PANEL UPON COMPLETION OF JOB. <br /> 8b 4b ( 12 <br /> a 2a a 4 4 C I 8 ABOVE LOW ANDCONDUIT WIRING <br /> USINGALL BE MOUNTED +7'STRUUT-TYPE CHANNEL <br /> 8' <br /> 8b 10c <br /> 12b 5a FASTENED TO BUILDING STRUCTURAL MEMBERS. <br /> 12 10b 8 5a 8b H 9. COORDINATE LOCATION OF ALL LUMINAIRES WITH OTHER <br /> q2E5j03j <br /> 12a Oc 2 SICK BAY BUILDING TRADES BEFORE INSTALLATION. <br /> 12b 12b 112b 12 12b 1 � 12c 1�=-� 12 12a <br /> �^ 1 a 10."UNSWITCHED" LIGHTS TO BE WIRED DIRECTLY TO THE <br /> "I <br /> PANELBOARD BYPASSING THE CONTACTORS. <br /> 8a A I 11.SEE DETAIL SHT. E507 FOR LIGHTING CONTROL. <br /> (VIP) 450 <br /> 12 ABANDONED LIGHTING FIXTURE LOCATION. REFER TO <br /> K <br /> 424 8 ® 450 ® DETAIL J ON DRAWING 45-001-E503. <br /> (TYP <br /> (nP) �11c I (TYP) 11c 11c 13 UNSWITCH LIGHTING FIXTURE "ON" 24/7. <br /> 4 LUMINAIRE RETROFITTED WITH LED LAMP REPLACEMENT. <br /> 1 1 1 110 nE,9b <br /> 12 REFER TO DETAIL A ON DRAWING 45-001-E503-1. <br /> 2 „b 9c 7a ° 7b 7c 11b ;,,—SICK BAY REFERENCE DRAWINGS <br /> J 45-001-EOA SYMBOLS, ABBREVIATIONS AND <br /> 11b 11b 1b 1c A 1 FIXTURE SCHEDULE <br /> 45-001-E503 DETAILS - LIGHTING <br /> 7c 9 4 14 C 1E12 E503 45-001-E503-1 LIGHTING DETAILS <br /> Ir 3 �� A TYP „b ga C 2 CONSTRUCTION NOTES <br /> 7c <br /> 4b 3V01-1K2/11a,11b,11c 450 5a 5a <br /> 3/4"C,4#8 & 1#10 GNDI <br /> VIA LIGHTING CONTACTOR PROVIDE LED HIGH BAY LIGHTING FIXTURE. REFER TO <br /> H K �7c 45-001 EOAFIXTURE EDULE SHOWN(TYP. (6) 'A' FIXTURE REFERENCE <br /> TTH S SHEET).DRAWING <br /> 14 14 3V01-iK2/Sb <br /> 1E12 E503 424 ga (TYR) 9a 9a 1/2"C 2#10 FIXTURE TO BE MOUNTED AS SHOWN ON DETAIL A ON <br /> 8a 9a I & 1#12 GND REFERENCE DRAWING 45-001-E503. <br /> MATCH LINE <br /> SEE SHT. 1E14 CONT'D ON C <br /> CONTINUED ON DRAWING DWG 1E14. SICK BAY <br /> 45-001-1E14 <br /> — _ 3V01-1K2/7a.7b.7c,9_a9b,9c — SEE SHT. E504 — — — — — <br /> 1"C, 8#8,1#10G FOR SWITCHING <br /> VIA LTG CONTACTOR V01-iK2/5a <br /> 1/2"C, 2#10 <br /> & 1#12 GND <br /> C <br /> 0.4 1 3 5 7 1 13 15 <br /> A <br /> PLAN VIEWN <br /> — <br /> SCALE: 1/8"=1'-O" G <br /> 1E10 Fl E-1 11 E <br /> G <br /> H <br /> !117 <br /> 1E13 <br /> J <br /> K <br /> 1E15 M <br /> P <br /> 8' 4' 0 4' 8' 16' R <br /> * DENOTES DRAWING NOT INCLUDED IN THIS SET. <br /> 01 77KEY PLAN BLDG. 45-01 <br /> SCALE: 1/8"V-0" SCALE: NONE <br /> DAT <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY AASWN O6E02-95 SUBTITLE PARTIAL FIRST FLOOR CURRENT REVISION SYMBOL DATE <br /> RECORD DRAWING ISSUED TO OWNER AAS JRB 11/25/96 THIS DESIGN AND/OR CHERCKED 06-02-95 LIGHTING PLAN W9148950 C 08.25.23 0 <br /> ` SPECIFICATION IS APPROVED SHEET <br /> A ADDED HID LIGHTING DETAIL BUG NJK — 07/31/03 �OL,��® ENGINEER rlrEe 1 E 12 <br /> Y APPROVED BY DEPT. DATE EAASNG 06-02-95 m <br /> B 45-001 LIGHTING UPGRADES — RECORD DRAWINGS 1786915 CEI PWJ 12.03.21 CHECKED <br /> APPROVED 06-02-95 BUILDING 45-001 <br /> JOB N0. COMP No. <br /> C PAINT HANGER LIGHTING IMPROVEMENT W9148950 CSL MDK 08.25.23 <br /> APPROVED ELECTRICAL MASTER COL. G-K/1-9 EVERETT, WA DWG N0. 45-001-1E12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.