Laserfiche WebLink
Q LEGEND <br /> 1 424 (�P) 4 5 6 7 (� 9 SEE DWG 45-001—EOA, FOR LEGEND AND ABBREVIATIONS. <br /> SEE NOTE 2 (TYR) GENERAL NOTES <br /> . UNLESS OTHERWISE NOTED ALL CONDUIT IS 3/4" EMT. <br /> 80 _21b _ _ _ _ 8b —MATCH LINE SEE SHT. 1E112 _ _ _ <br /> 8a Bc E E 8b ib E 15 2a 4a 6c 2. UNLESS OTHERWISE NOTED WIRE IS STRANDED, COPPER <br /> ONE <br /> 11a 6c 8b b 4b 14 TYPE THHN INSULATION, #12 AWG FOR POWER AND <br /> 7b — — F — — — — K #14 FOR CONTROL. <br /> � 14 <br /> ❑ ❑ 14 6a w 3. THE FOLLOWING COLOR CODING OF CONDUCTOR SHALL <br /> 'X\ I 3V01—iK2 8a,8b,8c 3V01-1 DOWN FIRST FLOOR ~�' BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. <br /> 3/4"C, 4# & 208Y 120V 480Y 277V <br /> 1/10 GND EASTSIDE PANEL VO1-1D7/21,23 3b F 14 <br /> LI HTING 3/4"C, #8 & 1#12 GND \ w A (LFT BUS IN PNL) BACK BROWN <br /> VIA LTG CONTACTOR C NTACTO 3b 20 B � (CNTR BUS IN PNL) RED ORANGE <br /> 3V01—iK2/ a,2b,2c,4a,4b,4c 4a <br /> PA EL 1#10 GND \ 3\ z C (RGHT BUS IN PNL) BLUE YELLOW <br /> 3V 1-1K2 7a,7b,7c,9a,9b,9c VIA LTG CONTACTOR 14 J NEUTRAL WHITE GRAY <br /> 1" , 8#8 & 1#10 GND 3V01—iK2/6a,6b,6c 3b 6b EQUIPMENT GROUND GREEN GREEN <br /> VIA LTG C NTACTOR 3/4"C, 4#8 450 (TYR) 71 ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> — — VIA LTG CONTACTOR (TYR) L REPLACE J—BOX *GREEN WITH YELLOW TRACER <br /> ❑ ❑ B CEILING 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE <br /> COLORED JACKETS SHALL BE IDENTIFIED WHEREVER <br /> 1E14 E50/ 2b is 4b REPLACE FLEX VISIBLE BY APPROPRIATELY COLORED TAPE. <br /> 4c <br /> A H>Ely 5. FOR PANEL SCHEDULES SEE SPECIFICATIONS. <br /> 1 E�4 (E) FIXTURE <br /> 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION <br /> CONNECTION DETAIL BOXES, SWITCHES, ETC, WITH PANEL AND CIRCUIT <br /> (E) SEAL H SCALE: NTS 1E14 DESIGNATION. <br /> (E) SEAL OFF / OFF K <br /> 424 1E14 E503 ^^ 7. POST NEW OR REVISED PANEL SCHEDULES IN <br /> R2 6b 1 b VI ELECTRICAL PANEL UPON COMPLETION OF JOB. <br /> 8. CONDUIT AND WIRING SHALL BE MOUNTED +7' TO 8' <br /> 2a F ABOVE LOW ATTIC USING STRUT—TYPE CHANNEL <br /> FASTENED TO BUILDING STRUCTURAL MEMBERS. <br /> 9. COORDINATE LOCATION OF ALL LUMINAIRES WITH OTHER <br /> BUILDING TRADES BEFORE INSTALLATION. <br /> 15 I 10."UNSWITCHED" LIGHTS TO BE WIRED DIRECTLY TO THE <br /> F' PANELBOARD BYPASSING THE CONTACTORS. <br /> N 11.SEE DETAIL DWG 45-001—E507 FOR LIGHTING <br /> 3V01-1K2/3b,12a,12b 4b CONTROL. <br /> 1"C, 2#8 & 1#10 GND <br /> VIA LTG CONTACTOR 12.SEE DWG 45-001-1E15 FOR CONTINUATION. <br /> \ P` 13.SEE DWG 45-001-1E513 FOR REMOTE BALLAST WIRING <br /> 11E14 E503 CONFIGURATION <br /> 3b 14 ABANDONED LIGHTING FIXTURE LOCATION. REFER TO <br /> \ I DETAIL J ON DRAWING 45-001—E503. <br /> P 15 UNSWITCH LIGHTING FIXTURE "ON" 24/7. <br /> P.1 REFERENCE DRAWINGS <br /> 45-001—EOA SYMBOLS, ABBREVIATIONS AND <br /> FIXTURE SCHEDULE <br /> 45-001-1E15 PARTIAL FIRST FLOOR LIGHTING PLAN <br /> 45-001—E503 DETAILS — LIGHTING <br /> 45-001—E507 CONTROL DIAGRAM AND DETAILS <br /> 45-001—E513 ADDITIONAL HID LIGHTING DETAILS <br /> I <br /> CONSTRUCTION NOTES <br /> I I I I I I I Q <br /> I I I I I I I I <br /> R 0.4 1 3 5 7 9 11 13 15 A <br /> I <br /> C <br /> T 1-El 0 Fl E-1 11 E <br /> � I <br /> / 0 <br /> 6.1 9 <br /> 1E12A 1 E1 2 1E13 <br /> L PARTIAL PLAN VIEW , �`� K <br /> SCALE: 1/8" = 1'-0" N 1E14 E15 M <br /> FOR REFERENCE ONLY <br /> P <br /> FACILITY DESIGN BY C.LEE DATE 08.25.23 _F E: <br /> 8 4' 0 4' 8' 16' <br /> MINKEY PLAN BLDG. 45-01 R <br /> SCALE: 1/8"=1'-0" SCALE: NONE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED I I ACCEPTABILITY DRAWN DATE SUBTITLE PARTIAL FIRST FLOOR CURRENT REVISION SYMBOL DATE <br /> THIS DESIGN AND/OR CHECKED LIGHTING PLAN w9148950 - 08.25.23 <br /> A 45-001 LIGHTING UPGRADES 1786915 CEI PWJ 12.20.19 SPECIFICATION IS APPROVED SHEET <br /> BOE//VG <br /> B HAZARDOUS LOCATIONS— RECORD DRAWINGS 1786915 CEI PWJ 12.03.21 ® APPROVED BY DEPT, DATE ENGINEER <br /> TITLE <br /> — PAINT HANGER LIGHTING IMPROVEMENT W9148950 CST MDK 08.25.23 CHECKED 1 E 14 <br /> APPROVED BUILDING 45-001 JOB NO. COMP NO. <br /> APPROVED ELECTRICAL MASTER COL. K—P/1-9 EVERETT, WA DWG NO. 45-001-1E14 <br />