Laserfiche WebLink
�I) <br />� �) � ") \, ''J \ 11�J <br />T'rFICAL FLOOR NOTES: <br />I. INSTALL SMOKE DETECTORS IN ALL SLEEPING ROOMS AND AT AREAS ADJACENT <br />TO SLEEPING ROOMS, AND AT CEILING WEIGHT CHANGES GREATER THAN 24'. <br />SMOKE DETECTORS TO BE HARD -WIRED AND INTERCONNECTED, WITH BATTERY <br />BACK-UP PER CODE. <br />SO <br />2. INSTALL CARBON MONOXIDE SENSORS ADJACENT TO SLEEPING AREAS. <br />3. ALL INTERIOR WALLS TO BE 2x4 m IS' O.O. (UN.O.) <br />4. ALL EXTERIOR WALLS TO BE 2x6 • 1( ' O.O. (UN.O.) <br />5. MAIN FLOOR HEADERS PER STRUCTURAL • 8'-C' AFF. (IUN.O.) <br />6. WINDOW SIZES ARE NOMINAL ROUGH OPENING, WIDTH AND HEIGHT. <br />T. DOOR SIZES NOTED ARE SLABS NOT ROUGH OPENINGS <br />e. PROVIDE FIREBLOCKING AT ALL PLUMBING OPENINGS. <br />9. PROVIDE SOLID BLOCKING OVER SUPPORTS. <br />10 WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED <br />SPACE OF A FLOOR -CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO <br />THAT THE AREA OF CONCEALED SPACE DOES NOT EXCEED 1000 SF. <br />DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY <br />EQUAL AREAS AND SHALL BE OF X' GYP BOARD OR OTHER APPROVED <br />MATERIALS INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS PER COD£, <br />11, PROVIDE FIREBLOCKING TO GUT OFF ALL CONGEALED HORIZONTAL AND <br />VERTICAL DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER <br />BETWEEN STOIRES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. <br />FIREBLOCKING SHALL CONSIST OF NOT LESS THAN 2' NOMINAL LUMBER OR <br />OTHER APPROVED MATERIAL. <br />12. ASPHALT -SATURATED FELT FREE FROM HOLES OR BREAKS, WEIGHING NOT LE55 <br />THAN 14 POUNDS PER 100 SQUARE FEET AND COMPLYING WITH ASTM D 226 OR <br />OTHER APPROVED WEATHER RESISTANT MATERIAL SHALL BE APPLIED OVER <br />SHEATHING OF ALL EXTERIOR WALLS. APPROVED ALTERNATIVE WEATHERPROOF <br />MEMBRANES SHALL BE USED FOR OPEN JOINT RAIN SCREEN SIDING. WEATHER <br />RESISTANT MATERIALS SHALL BE APPLIED HORIZONTALLY PERMANUFACTURERS <br />RECOMMENDATIONS, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER <br />NOT LESS THAN 2 INCHES AND NOT LESS THAN 6 INCHES WHERE JOINTS OCCUR <br />PER CODE. <br />13. APPROVED CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER <br />INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDINGS <br />STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE <br />SURFACE OF THE EXTERIOR WALL SURFACE AND SHALL BE INSTALLED TO <br />PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE. FLASHING <br />SHALL BE INSTALLED AT, BUT NOT LIMITED TO THE FOLLOWING LOCATIONS: <br />-THE TOP OF ALL EXTERIOR WINDOW 4 DOOR OPENINGS <br />-INTERSECTIONS OF FRAME WALLS AND MASONRY OR STUCCO <br />-UNDER MASONRY, WOOD OR METAL COPINGS AND SILLS <br />-CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM <br />-WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL <br />-AT WALL AND ROOF OR SOFFIT INTERSECTIONS <br />-AT BUILT-IN GUTTERS <br />14. EXTERIOR LOCATIONS FOR ENVIRONMENTAL AIR DUCT EXHAUST 4 INTAKE <br />OPENINGS TO BE A MINIMUM OF V-O' FROM PROPERTY LINE a MINIMUM 3'-0' <br />FROM BUILDING OPENINGS. EQUIP ALL DUCTS W/ BACK -DRAFT DAMPERS. <br />15. AIR EXHAUST 4 INTAKE OPENINGS THAT TERMINATE OUTDOORS SHALL BE <br />PROTECTED W/ CORROSION RESISTANT SCREENS, LOUVERS, OR GRILLS W/ 1/4' <br />MINIMUM 4 1/2' MAX OPENINGS IN ANY DIMENSION. OPENINGS SHALL BE <br />PROTECTED AGAINST LOCAL WEATHER CONDITIONS PER 2015 IRC. <br />16. DUCTS FOR KITCHEN RANGES SHALL BE OF METAL AND BE EQUIPPED W/ <br />BACK -DRAFT DAMPERS PER CODE. <br />11. ALL INTERIOR FINISHES TO MEET MINIMUM FLAME SPREAD INDEX AND SMOKE <br />DEVELOPMENT NDEX AS REQUIRED BY 2015 IRC. <br />18. UNDER FLOOR GLEANOUT NOT MORE THAN 20' FROM ACCESS DOOR WITH AN <br />UNOBSTRUCTED 30' WIDE X IS' HIGH PATH PATHWAY. CLEANOUTS ARE <br />ACCESSIBLE. 12' CLEARANCE REQUIRED AT LINES LESS THAN OR EQUAL TO 2', 16' <br />CLEARANCE AT LINES GREATER THAN 2'. (UPC 107.S) <br />10. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIFDING AND <br />51FOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION, SAFETY <br />GLAZING. <br />GARAGE NOTES_ <br />1. GARAGES SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA <br />BY NOT LESS THAN 5/5' TYPE X GLIB APPLIED TO THE GARAGE SIDE. WHERE THE <br />SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE <br />SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN W TYPE X <br />GYPSUM BOARD OR EQUIVALENT. <br />2. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH <br />SOLID WOOD DOOR$ NOT LESS THAN 1 3/8' IN THICKNESS, SOLID OR HONEYCOMB <br />GORE STEEL DOORS NOT LESS THAN 1 3/8' THICK, OR 20-MINUTE FIRE -RATED <br />DOORS. <br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS <br />SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A <br />MINIMUM NO. 26 GAGE SHEET STEEL OR OTHER APPROVED MATERIALS AND <br />SHALL HAVE NO OPENINGS INTO THE GARAGE. IRC R30S.1.1 <br />4. IN SIESMIC ZONES 3 t 4, WATER HEATERS SHALL BE ANCHORED TO RESIST HORZ. <br />DISPLACEMENT DUE TO EARTHQUAKE MOTION. STRAPPING SHALL BE A POINTS <br />WITHIN THE UPPER ONE THIRD AND LOWER ONE THIRD PER UPC SEC. 5105 <br />5, PROVIDE OUTDOOR COMBUSTION AIR FOR WATER HEATER <br />6. GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE <br />MATERIAL AND THE AREA USED FOR THE PARKING OF AUTOMOBILES OR OTHER <br />VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A <br />DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. <br />,,4 1 WAY FLOOF,FLAN <br />SCALE: 1/4' • 1'-0' <br />EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE INSTALLED <br />IN EVERY SLEEPING ROOM BELOW THE 4TH STORY AND IN <br />BASEMENTS. <br />OPENABLE W/O KEYS OR SPECIAL TOOLS <br />• MIN. 5.1 SF NET CLR OPENABLE AREA <br />• MIN. 24' NET CLR OPENABLE HEIGHT <br />• MIN. 20' NET CLR OPERABLE WIDTH <br />• MAX. 44' FINISHED SILL HEIGHT <br />IRC R310 4 IBC 1030. <br />AREA SUMMAR`I' <br />MAIN FLOOR <br />1,522 <br />ef. <br />UPPER FLOOR: <br />1,816 <br />ef. <br />TOTAL: <br />3,398 <br />sf. <br />GARAGE: <br />816 <br />sf. <br />PORCH: <br />52 <br />sf. <br />COV'D PATIO: <br />315 <br />sf. <br />UNCOV'D PATIO: <br />142 <br />sf. <br />FREESTANDING RANGE AND RANGE HOOD: <br />MI903.4 MAKEUP AIR REQUIRED: <br />EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF 400 CUBIC FEET <br />PER MINUTE (0.19 M3/8) SHALL BE MECHANICALLY OR NATURALLY PROVIDED WITH <br />MAKEUP AIR AT A RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH <br />MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH NOT LESS THAN ONE DAMPER <br />EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN ELECTRICALLY OPERATED <br />DAMPER THAT AUTOMATICALLY OPENS WHEN THE EXHAUST SYSTEM OPERATES. <br />DAMPERS SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND <br />REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION OR ANY OTHER <br />DUCTS NOT CONNECTED TO THE DAMPER BEING INSPECTED, SERVICED, REPAIRED <br />OR REPLACED. <br />KITCHEN EXHAUST MAKEUP AIR SHALL BE DISCHAR'sED INTO THE SAME ROOM IN <br />WHICH THE EXHAUST SYSTEM IS LOCATED OR INTO ROOMS OR DUCT SYSTEMS THAT <br />COMMUNICATE THROUGH ONE OR MORE PERMANENT OPENINGS WITH THE ROOM IN <br />WHICH SUCH EXHAUST SYSTEM 19 LOCATED. SUCH PERMANENT OPENINGS SHALL <br />HAVE A NET CROSS -SECTIONAL AREA NOT LESS THAN THE REQUIRED AREA OF THE <br />MAKEUP AIR SUPPLY OPENINGS. <br />G240T.9.1 (304.9.0 MAKEUP AIR <br />WHERE EXHAUST FANS ARE INSTALLED, MAKEUP AIR SHALL BE PROVIDED TO <br />REPLACE THE EXHAUSTED AIR <br />G2401.91 (304.52) APPLIANCE INTERLOCK <br />EACH OF THE APPLIANCES SERVED SHALL BE INTERLOCKED WITH THE MECHANICAL <br />AIR SUPPLY SYSTEM TO PREVENT MAIN BURNER OPERATION WHEN THE MECHANICAL <br />AIR SUPPLY SYSTEM IS NOT IN OPERATION. <br />WHERE COMBUSTION AIR IS PROVIDED BY THE BUILDING'S MECHANICAL <br />VENTILATION SYSTEM, THE SYSTEM SHALL PROVIDE THE SPECIFIED COMBUSTION AIR <br />RATE IN ADDITION TO THE REQUIRED VENTILATION AIR <br />APPLIANCES: <br />I. THOR KITCHEN HW.3618U 36' PRO -STYLE 6 STAINLESS STEEL BURNER GAS <br />RANGE. <br />2. THOR KITCHEN HRH3606U 36' STAINLESS STEEL UNDER CABINET RANGE HOOD. <br />� I ) RANGE 8 HOOD <br />SMOKE 4 CARBON MONOXIDE ALARMS: <br />SMOKE AND CARBON MONOXIDE ALAR1MS MUST BE PROVIDED IN ALL REQUIRED <br />LOCATIONS AND MUST BE: <br />• AUDIBLE IN ALL PARTS OF THE HOUSE <br />INSTALLED PER MANUFACTURER'S INSTRUCTIONS <br />NEW HOUSES NRC R314 I R315) <br />SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED AND MUST BE <br />CONNECTED TO THE MAIN ELECTRICAL SYSTEM WITH BATTERY BACKUP. <br />CARBON MONOXIDE ALARMS ARE REQUIRED IN ALL NEW AND EXISTING HOMES, <br />APARTMENTS, CONDOMINIUMS, AND OTHER MULTI -FAMILY UNITS. <br />REQUIRED LOCATIONS <br />• SMOKE ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM AND IN NAPPING <br />AREAS IN A FAMILY HOME CHILD CARE. <br />• SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE LOCATED OUTSIDE <br />EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. <br />• SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE LOCATED ON EVERY <br />FLOOR LEVEL, INCLUDING BASEMENTS (DOES NOT INCLUDE CRAWLSPACE AND <br />UNINHABITABLE ATTICS). <br />• IN SPLIT LEVEL FLOOR PLANS, AT THE UPPER LEVEL, PROVIDED THERE IS NO <br />INTERVENING DOOR BETWEEN ADJACENT LEVELS AND THE LOWER LEVEL IS LESS THAN <br />A FULL STORY BELOW THE UPPER LEVEL <br />• A CARBON MONOXIDE ALARM 19 REQUIRED IN A BEDROOM WHEN A FUEL -BURNING <br />APPLIANCE IS INSTALLED IN THE BEDROOM OR ITS ATTACHED BATHROOM. <br />A COMBINATION ALARM (COMBINED SMOKE AND CARBON MONOXIDE ALARM) IS <br />ACCEPTABLE IN ANY REQUIRED LOCATION. <br />-WALL MOUNTED ALARMS MUST BE NOT MORE THAN 12 INCHES FROM THE ADJOINING <br />CEILING SURFACE. <br />AVOID PLACING ALARMS LESS THAN 3 FEET FROM SUPPLY REGISTERS OF A FORCED <br />AIR HEATING OR COOLING SYSTEM AND DO NOT PLACE ALARMS IN THE DIRECT <br />ARFLOW OF THE REGISTERS. <br />• AVOID PLACING ALARMS WITHIN 3 FEET HORIZONTALLY FROM DOORS TO BATHROOMS <br />CONTAINING A BATHTUB OR SHOWER <br />• DO NOT PLACE ALARMS M SPACES WHERE TEMPERATURES MAY BE ABOVE OR <br />BELOW THE ALARM'S OPERATING TEMPERATURE RANGE. <br />• DO NOT PLACE ALARMS WITHIN 3 FEET OF THE BLADES OF A CEILING FAN. <br />• ALARMS IN PEAKED OR SLOPED CEILINGS MUST BE WITHIN 3 FEET OF THE PEAK <br />MEASURED HORIZONTALLY, BUT NOT IN THE HIGHEST 4 INCHES OF THE CEILING, <br />MEASURED VERTICALLY. <br />A. PHOTOELECTRIC SMOKE ALARMS MUST NOT BE LESS THAN 6 FEET FROM A <br />PERMANENT COOKING APPLIANCE. <br />B. IONIZATION SMOKE ALARMS WITH AN ALARM -SILENCING SWITCH MUST NOT BE LESS <br />THAN 10 FEET FROM A PERMANENT COOKING APPLIANCE. <br />101 <br />IN <br />C <br />Le <br />O <br />R <br />C <br />C. IONIZATION SMOKE ALARMS WITHOUT AN ALARM -SILENCING SWITCH MUST NOT BE LESS <br />NOTE: <br />THAN 20 FEET FROM A PERMANENT COOKING APPLIANCE <br />ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE <br />SHALL BE RATED AT 1.15 GPM OR LESS. ALL OTHER LAVATORY FAUCETS <br />CARBON MONOXIDE ALARM LOCATION LIMITATIONS <br />SHALL BE RATED AT 1.0 GPM OR LESS. <br />• DO NOT PLACE ALARMS DIRECTLY ABOVE OR BESIDE FUEL -BURNING APPLIANCES. <br />• DO NOT PLACE ALARMS IN DIRECT SUNLIGHT. <br />• DO NOT PLACE ALARMS IN LOW AREAS WHERE CHILDREN CAN REACH. DO NOT PLACE <br />Ct <br />ALARMS BEHIND CURTAINS OR ANY STRUCTURE THAT MIGHT PREVENT CARBON <br />MONOXIDE FROM REACHING THE SENSOR <br />( N <br />NOTE; <br />EACH DOOR TO BE UNDERCUT A MINIMUM OF 1/2-INCH TO ASSURE FREE <br />�� <br />FLOW OF FRESH AIR THROUGHOUT HABITABLE ROOMS <br />NOTE: <br />CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT <br />NOTE: <br />AND REPORT ANY CMI$VONS / DISCREPANCIES TO DESIGNER PRIOR TO <br />REFER TO STRUCTURAL SHEETS FOR SHEAR WALL SCHEDULE AND <br />COMMENCING WORK DESIGNER SHALL NOT BE RESPONSIBLE FOR <br />ENGINEERING PLAN WHICH CONTAIN REFERENCES AND/OR INSTRUCTIONS <br />DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PERFORMED <br />PERTAINING TO EACH SHEAR WALL INDICATED IN THIS PLAN <br />BY THE CONTRACTOR <br />20'-4' <br />- <br />- <br />- <br />EARWALL P <br />R 9TRUC <br />LINE <br />OF LOOR ABOVE_ <br />- <br />RAL A <br />ENGINEERING <br />E -SHEETS <br />6° BLDR <br />I_I01e <br />W CONC. <br />w <br />,2 <br />LL INDO HEADER -3- ' AFF F V- ' GLG. <br />D I I Nr <br />GANTILE <br />� <br />' WI CT <br />.INSTALL 36 DE 'DIRECT <br />' VENT AS FIREPLACE PER <br />G <br />SPECS.': ' <br />�.. a 15 -8 X 12 -8 <br />MANUF. <br />IONIZATION 9M ALARM <br />' <br />r <br />N <br />W <br />SHALL NOT BE IN TILLED <br />LESS THAN 20 FtT <br />N <br />HORIZONTALLY <br />- <br />PERMANENTLYLLE0 <br />COdCING APPLI. <br />(P <br />Y > <br />COVD PATIO <br />INSTALL 36'WIDE DIRECT <br />VEMANTIF AS FIREPLACE PER <br />W <br />�aQ <br />., <br />N <br />IV-O' X 23 -m' '. ''. <br />0 <br />t�17 Y, <br />I <br />LL <br />"' <br />OPEN TO ABOVE Ilu <br />SLAND <br />GREAT RNf. <br />1 <br />o "o <br />S 24'-10' X 21'-2' J <br />a <br />m" <br />m Xj <br />0 <br />f <br />W <br />®,p <br />I <br />p¢ <br />to <br />9 6., 4,0 .: <br />II'-G, 4'-0, 4,-4, 4:_8. :_6: <br />,_0• <br />CIur <br />�V-O'ICLG. <br />t, � <br />' KIT H V - <br />- <br />LINE OF FLOOR ABOVE <br />- - ___w 4- 5'-6 - <br />CLOSET WALL/DOOR IF CLOS FD 4 <br />RISER STAIR IS INSTALLED B �� <br />m <br />l n OVENS i <br />®®® 9 <br />y <br />N 2mdl <br />OPEN RIOPTIONSER ER STAIRCASE <br />Q <br />S <br />k A PER MANUFACTURER <br />iu _Uu4 <br />N LIN E ABOVE liL sue- <br />US W <br />XQ <br />R. e 8. �1 <br />° 0' A2 OPTIONALSINK <br />--- <br />OPEN TO A5V. <br />2 <br />d <br />9'-O'GLG. I LLO_____ <br />11'-3' X I0'-0' PANTRY <br />OFF I CE A, -- ----- <br />la al <br />s <br />"'go F,® <br />^•� <br />12'-6' X 12'-2' -' -- <br />i 9 1:-&, 4'-m' riQ fr R 1 8. SHELVES <br />L_ <br />GUARD RAILS MUST BE N. R- I <br />I` <br />�A <br />0 <br />ABLE TO WITHSTAND A a _ a IN9ULA ION, TYP. <br />m m <br />4 <br />9 <br />N <br />CONCENTRATED LOAD ''I- <br />© F'ROVI E ONE (1) rryv R FIB �- <br />OF 200 Ibe. APPLIED AT s� SEPA TION FOR u I ING <br />A5 Q <br />d1 <br />r <br />ANY POINT ALONG THE <br />® - AREA5 ADJACENT BOVE : <br />- <br />r <br />- <br />- <br />RAIL IN ANY DIRECTION. <br />PER TABLE IW3015 - - - .. _..- .=4.... <br />m "" UP I6 RISERS 18' H PLATFORM <br />~ <br />U 4' CONC. B W/ (2) LAYERS <br />111I <br />qk� SAFETY GLASS LANDING 3/4' PLYWOOD <br />m <br />Tnm •LOWER WINDOWS 1 -0. X 5 1' `f SAFETY GLASS : :I 4' DIA. STEEL <br />BOLLARD EMBED ?4' <br />- Im OPENINGS BETWEEN THE GAR4GE <br />3.13 PI 3ele IC. BLW. ' 3 !� PIC. 3 r� PIG <br />9 <br />, <br />a <br />m <br />.BLW. RESIDENCE 8H L <br />3°5e PIC 3`5° PIC DN _' W DOW HEADS AND BE <br />a FF. '_, ' QUIPPED WITH SOLI WOOD <br />LI E OF FLOOR ABOVE DOORS NOT LESS TH N 11' INCHES <br />^ <br />W P <br />. <br />- - - - DO, UU.IVPPEMI DTWITH AA SELF <br />_ -LU <br />K0 <br />,EE <br />d <br />LIGHTWEIGHT ' 4' CONRE'TE I <br />U � Q <br />0 <br />' STONE <br />. VENEER, TYP I, ..'.'�: 3-C R IS RAGE <br />rUU <br />wuI <br />3 j 20'-O' X -2' <br />w W <br />Zpu <br />0 <br />GARAGE(yWELLING SEPERATION p I <br />ON THE G RAGE SIDE OF WALLS Q <br />AND CEILING WITH IN. IR' GWB <br />AND 5/&' F H H 'X' AT U' <br />I .... I CEILING W TH HABI LE ROOM <br />0, <br />GONG-TE DRIVE, WAY AI ABOVE C BLE R302b). <br />- <br />� <br />0 <br />0 <br />I. DsA)r/C►S LeLY477 G�frrCM1,��1 cpuI <br />- <br />m <br />1/V�sig2.:yib(6 �A�Lsr2l ,F1EA�7� /ra,� , j <br />m <br />m <br />SLOFE <br />�--�qvrpolv <br />'ORDTGAR. DIR , <br />_J <br />I <br />LINE OF FLOiJR ABOVE__ <br />W. <br />in <br />77QQ�� I <br />YJ '. � SLO TO DRAIN <br />,%�3pf111 - I O GARDR <br />20 5° <br />1'-3' <br />3'-6' <br />3'-6' <br />2'-5' <br />LIGH�tWEIGHT STONE 3) PIC <br />4'-2' I II' VENt{ER, TYP. 3 2'_3' 2 _6: <br />13'-6' <br />1'-m' <br />a'-6' <br />n'-a• Al 9'-a' <br />CITY <br />OF <br />EVE <br />REVIEWED FOR <br />O <br />Ee <br />U U U U <br />A' <br />W <br />2 <br />UJ <br />N <br />VI <br />WooW <br />J � <br />a <br />Z Z <br />NaNW <br />FN <br />� <br />a <br />a W <br />�' <br />F', <br />� <br />v <br />J J Q <br />JJNW <br />MiQ X �.Si <br />{- <br />IL o <br />w <br />/ <br />Lo <br />W <br />0 � <br />N m� <br />Z QWX <br />m� <br />Z <br />w <br />W <br />IIlLI <br />L <br />Z <br />W� <br />Y <br />mW <br />N <br />lu <br />a <br />a 9 <br />W <br />m <br />C <br />LLI <br />f- <br />B <br />u <br />C <br />Project # <br />17174 <br />RETT <br />Sh-t <br />PERMIT <br />A2 <br />