Laserfiche WebLink
TYPICAL FLOOR NOTES: <br />I. INSTALL SMOKE DETECTORS IN ALL SLEEPING ROOMS AND AT AREAS <br />ADJACENT TO SLEEPING ROOMS, AND AT CEILING HEIGHT CHANGES <br />A _ <br />GREATER THAN 24'. SMOKE DETECTORS TO BE HARD -WIRED AND <br />INTERCONNECTED, WITH BATTERY BACK-UP PER CODE. <br />2. INSTALL CARBON MONOXIDE SENSORS ADJACENT TO SLEEPING AREAS. <br />3. ALL INTERIOR WALLS TO BE 2x4 • IS' O.C. (UN.O.) <br />B - <br />4. ALL EXTERIOR WALLS TO BE 2x6 s 16' O.O. (UN.O.) <br />5. UPPER FLOOR HEADERS PER STRUCTURAL - 8'-O' AFF. (UN.O.) <br />6. WINDOW SIZES AIRS NOMINAL ROUGH OPENING, WIDTH AND HEIGHT. <br />C <br />1. DOOR SIZES NOTED ARE SLABS NOT ROUGH OPENINGS <br />5. PROVIDE FIREBLOCKING AT ALL PLUMBING OPENINGS. <br />S. PROVDE SOLID BLOCKING OVER SUPPORTS. <br />10 WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE <br />CONCEALED SPACE OF A FLOOR -CEILING ASSEMBLY, DRAFTSTOPS <br />SHALL BE INSTALLED 80 THAT THE AREA OF CONCEALED SPACE DOES <br />NOT EXCEED 1000 SF. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED <br />SPACE INTO APPROXIMATELY EQUAL AREAS AND SHALL BE or X' GYP <br />D - <br />BOARD OR OTHER APPROVED MATERIALS INSTALLED PARALLEL TO THE <br />FLOOR FRAMING MEMBERS PER CODE. <br />It. PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND <br />VERTICAL DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER <br />BETWEEN STORES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. <br />FIREBLOCKING SHALL CONSIST OF NOT LESS THAN 2' NOMINAL LUMBER <br />OR OTHER APPROVED MATERIAL. <br />12. ASPHALT -SATURATED FELT FREE FROM HOLES OR BREAKS, WEIGHING <br />NOT LESS THAN 14 POUNDS PER 100 SQUARE FEET AND COMPLYING WITH <br />ASTM D 226 OR OTHER APPROVED WEATHER RESISTANT MATERIAL <br />SHALL BE APPLIED OVER SHEATHING OF ALL EXTERIOR WALLS. <br />APPROVED ALTERNATIVE WEATHERPROOF MEMBRANES SHALL BE USED <br />FOR OPEN JOINT RAIN SCREEN SIDING. WEATHER RESISTANT MATERIALS <br />SHALL BE APPLIED HORIZONTALLY PERMANUFACTURERS <br />RECOMMENDATIONS, WITH THE UPPER LAYER LAPPED OVER THE LOWER <br />LAYER NOT LESS THAN 2 INCHES AND NOT LESS THAN 6 INCHES WHERE <br />JOINTS OCCUR PER CODE. <br />13. APPROVED CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED IN <br />THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT <br />ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO <br />THE BUILDINGS STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL <br />EXTEND TO THE SURFACE OF THE EXTERIOR WALL SURFACE AND SHALL <br />BE INSTALLED TO PREVENT WATER FROM REENTERING THE EXTERIOR <br />WALL ENVELOPE. FLASHING SHALL BE INSTALLED AT, BUT NOT LIMITED <br />TO THE FOLLOWING LOCATIONS: <br />-THE TOP OF ALL EXTERIOR WINDOW 4 DOOR OPENINGS <br />-INTERSECTIONS OF FRAME WALLS AND MASONRY OR STUCCO <br />-UNDER MASONRY, WOOD OR METAL COPINGS AND SILLS <br />E - <br />-CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM <br />-WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL <br />-AT WALL AND ROOF OR SOFFIT INTERSECTIONS <br />-AT BUILT-IN GUTTERS <br />14. EXTERIOR LOCATIONS FOR ENVIRONMENTAL AIR DUCT EXHAUST 4 INTAKE <br />OPENINGS TO BE A MINIMUM OF V-0' FROM PROPERTY LINE 4 MINIMUM <br />3'-0' FROM BUILDING OPENINGS. EQUIP ALL DUCTS W/ BACK -DRAFT <br />DAMPERS. <br />15. AIR EXHAUST 4 INTAKE OPENINGS THAT TERMINATE OUTDOORS SHALL BE <br />PROTECTED W/ CORROSION RESISTANT SCREENS, LOUVERS, OR GRILLS W/ <br />I/4' MINIMUM 4 1/2' MAX OPENINGS IN ANY DIMENSION. OPENINGS SHALL <br />BE PROTECTED AGAINST LOCAL WEATHER CONDITIONS PER 2015 IRC. <br />16, DUCTS FOR KITCHEN RANGES SHALL BE OF METAL AND BE EQUIPPED W/ <br />BACK -DRAFT DAMPERS PER CODE. <br />IT. ALL INTERIOR FINISHES TO MEET MINIMUM FLAME SPREAD INDEX AND <br />�\ <br />SMOKE DEVELOPMENT INDEX AS REQUIRED BY 2015 IRC. <br />18. UNDER FLOOR CLEANOUT NOT MORE THAN 20' FROM ACCESS DOOR WITH <br />AN UNOBSTRUCTED 30' WIDE X 18' HIGH PATH PATHWAY. CLEANOUTS ARE <br />ACCESSIBLE. 12' CLEARANCE REQUIRED AT LINES LESS THAN OR EQUAL <br />�q <br />TO 2', IS' CLEARANCE AT LINES GREATER THAN 2'. (UPC 101.9) <br />IS. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIFDING <br />AND BIPOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION, <br />SAFETY GLAZING. <br />- <br />N — <br />SMOKE 4 CARBON MONOXIDE ALARMS: <br />I — <br />SMOKE AND CARBON MONOXIDE ALARMS MUST BE PROVIDED IN ALL REQUIRED <br />LOCATIONS AND MUST BE: <br />J <br />• AUDIBLE IN ALL PARTS OF THE HOUSE <br />• INSTALLED PER MANUFACTURER'S INSTRUCTIONS <br />NEW HOUSES ORC R314 4 R3I5) <br />K <br />SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED AND MUST BE <br />CONNECTED TO THE MAIN ELECTRICAL SYSTEM WITH BATTERY BACKUP. <br />CARBON MONOXIDE ALARMS ARE REQUIRED IN ALL NEW AND EXISTING HOMES, <br />APARTMENTS, CONDOMINIUMS, AND OTHER MULTI -FAMILY UNITS. <br />R=QJIR=D LOCATIONS <br />• SMOKE ALARM9 SHALL BE LOCATED IN EACH SLEEPING ROOM AND IN NAPPING <br />AREAS IN A FAMILY HOME CHILD CARE. <br />• SMOKE ALARMS AND CARBON MONOXIDE ALAR-IS SHALL BE LOCATED OUTSIDE <br />EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. <br />•SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE LOCATED ON EVERY <br />FLOOR LEVEL, INCLUDING BASEMENTS (DOES NOT INCLUDE GRAWLSPACE AND <br />UNINHABITABLE ATTICS). <br />• IN SPLIT LEVEL FLOOR PLANS, AT THE UPPER LEVEL, PROVIDED THERE 19 NO <br />INTERVENING DOOR BETWEEN ADJACENT LEVELS AND THE LOWER LEVEL IS LESS THAN <br />A FULL STORY BELOW THE UPPER LEVEL <br />• A CARBON MONOXIDE ALARM 19 REQUIRED IN A BEDROOM WHEN A FUEL -BURNING <br />APPLIANCE 19 INSTALLED IN THE BEDROOM OR ITS ATTACHED BATHROOM. <br />• A COMBINATION ALARM (COMBINED SMOKE AND CARBON MONOXIDE ALARM) 15 <br />ACCEPTABLE IN ANY REQUIRED LOCATION <br />-WALL MOUNTED ALARMS MUST BE NOT MORE THAN 12 INCHES FROM THE ADJOINING <br />CEILING SUM-ACE. <br />AVOID PLACING ALARMS LESS THAN 3 FEET FROM SUPPLY REGISTERS OF A FORCED <br />AIR HEATING OR COOLING SYSTEM AND DO NOT PLACE ALARMS IN THE DIRECT <br />AIRFLOW OFTHE <br />ALARERB. <br />• AVOID PLACING ALARM <br />S MS WITHIN 3 FEET HORIZONTALLY FROM DOORS TO BATHROOMS <br />I <br />CONTAINING A BATHTUB OR SHOWER <br />L <br />• DO NOT PLACE ALARMS IN SPACES WHERE TEMPERATURES MAY BE ABOVE OR <br />BELOW THE ALARM'S OPERATING TEMPERATURE RANGE. <br />• DO NOT PLACE ALARMS WITHIN 3 FEET OF THE BLADES OF A CEILING PAN. <br />• ALARMS IN PEAKED OR SLOPED CEILINGS MUST BE WITHIN 3 FEET OF THE PEAK, <br />MEASURED HORIZONTALLY, BUT NOT IN THE HIGHEST 4 INCHES OF THE CEILING, <br />MEASURED VERTICALLY. <br />A. PHOTOELECTRIC SMOKE ALARMS MUST NOT BE LESS THAN 6 FEET FROM A <br />PERMANENT COOKING APPLIANCE. <br />B. IONIZATION SMOKE ALARMS WITH AN ALARM -SILENCING SWITCH MUST NOT BE LESS <br />THAN 10 FEET PROM A PERMANENT COOKING APPLIANCE. <br />C. IONIZATION SMOKE ALARMS WITHOUT AN ALARM -SILENCING SWITCH MUST NOT BE LESS <br />THAN 20 FEET FROM A PERMANENT COOKING APPLIANCE <br />CARBON MONOXIDE ALARM LOCATION LIMITATIONS <br />• DO NOT PLACE ALARMS DIRECTLY ABOVE OR BESIDE FUEL -BURNING APPLIANCES. <br />• DO NOT PLACE ALARMS IN DIRECT SUNLIGHT. <br />• DO NOT PLACE ALARMS IN LOW AREAS WHERE CHILDREN CAN REACH. DO NOT PLACE <br />M <br />ALARMS BEHIND CURTAINS OR ANY STRUCTURE THAT MIGHT PREVENT CARBON <br />MONOXIDE FROM REACHING THE SENSOR <br />NOTE: <br />CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OF PROJECT <br />AND REPORT ANY OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR TO <br />COMMENCING WORK DESIGNER SHALL NOT BE RESPONSIBLE FOR <br />DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED WORK PER=ORMED <br />BY THE CONTRACTOR <br />- - bm FP SLDR - <br />9B <br />BEDRM. 3 <br />12'_6' X 13'-6' + - <br />lmv� <br />SD. <br />19'-10" <br />- A <br />I <br />LN. OF R BLW <br />I <br />36 66PIC PI 3666 WIC <br />30 sp PIC <br />CANTILEVER <br />S'-O' CLG. <br />BONUS <br />- <br />SD. <br />MANUAL OVERRIDE W/ <br />AUTO TIMER < WHOLE <br />\ HOUSE FAN SEE SHEET <br />A-1 FOR SPECIFICATION <br />FAN AND TIMER <br />0 <br />9n, V pm <br />OPEN <br />ORIR IM. <br />GREAT <br />i <br />BELOW <br />Y <br />------CLOSET------- <br />iv <br />I <br />W.G. <br />WE 18 REQUIRED ON BOTH SIDE OF <br />OPEN <br />HALL <br />0 <br />OPEN <br />STAIR <br />THE STAIR AND/OR SAFETY GLAZING 19 I <br />REQUIRED WHITHIN INCHES THE 8i IR <br />HALL <br />36 OF <br />RUN. GUARD RAILS MST BE ABLE TO <br />lr <br />0 <br />WITHSTAND A CONCENTRATED LOAD OF <br />9m <br />mm <br />IIOVO <br />2 <br />I.e. APPLIED AT ANY POINT ALONG THE IL <br />IN ANY OIFEECTION PER TABLE M01S <br />3 <br />r <br />9D <br />10 <br />IIOV <br />C.M. <br />S.D. <br />tWI� <br />CM. <br />_ Q <br />GUARDRAIL <br />BATH 2NI Ip <br />5 <br />p' <br />BRIDGE Al AT <br />LINEN <br />4'-6' <br />II'-6' 4'-0' v <br />4'-4" <br />4'- <br />GUARDRAIL H AFF. O <br />I <br />R48. <br />-------CLOSET ------ <br />4 <br />O <br />qq <br />OPEN TO <br />Q <br />FOTER tl <br />pn Si+1 26 <br />BELOW <br />0 <br />v T <br />FIRE BLOCKING SHALL EEZ <br />PROVIDED PER 2015 IRC R302.11 IN <br />-L_ <br />FULLIHEIGHT <br />LEI <br />ADDITIONAL FIREBLOCKING <br />IREBLALLS. CKI <br />WIN <br />OW HEADER <br />® <br />DETAILS SEE NOTES ON SHEET-A6 <br />• 1 <br />-0' AFF. (UPPOR <br />9'-0' CLG. 9D 0 <br />f. 2 <br />flD <br />GP40 PIC5EDRI" <br />12'-6' X 15'-0' <br />G <br />CATILEVER <br />GLASS <br />- <br />'0 <br />— SAFETY GLASS <br />LOWER WINDOWS <br />- 3IO IV <br />0 3 PIC. 3 C. <br />+ <br />3656 PIC 3656 PIC <br />r - <br />1 <br />- <br />.B 3 <br />- <br />C.B <br />- <br />- <br />LINE OF <br />ROOF BEL <br />24� <br />1_ 3'-8' 1. 3'-4' 1 6'-1' 1 P-11' <br />ME <br />9'-0' CLG. <br />I BEDRM- 4 <br />W-10' X <br />110vv <br />SD. <br />e a <br />I L11G <br />�4Am Gt <br />9'-0' CLG <br />1" ISTR.STE- <br />I6'-0' X I6' 6' + <br />i <br />A B <br />C <br />F� FF FL OO <br />SCALE: 1/4' . I'-0' <br />AREA SUMMARY' <br />L <br />FIRST FLOOR: <br />SECOND FLOOR <br />1,522 sf. <br />1,516 ef. <br />3 3 <br />TOTAL: <br />3A98 F. <br />W <br />GARAGE: <br />816 .F. <br />fp <br />PORCH: <br />52 F. <br />J <br />COV'D PATIO: <br />UNCOV'D PATIO: <br />31S F. <br />142 9f. <br />ICIUU 1�WU <br />J J <br />NOTE: <br />ALL SHOWERITEAD AND KITCHEN 51NK FAUCETS INSTALLED <br />IN THE HOUSE <br />SHALL BE RATED AT 1.15 GFMM OR LEGS. ALL OTHER LAVATORY FAUCETS <br />�\ <br />SHALL BE RATED AT 1.0 GPM OR LESS. <br />J <br />rJn <br />V <br />2 <br />Wj?co <br />OQWQ <br />o <br />W'^^0WI� <br />V/ O <br />�JOW <br />� WW�nW <br />E 30m <br />C7 <br />W <br />J <br />a mw <br />Z <br />N = Pr <br />W w -0 d: <br />0 m <br />W to <br />E <br />z wx <br />Q <br />In <br />E <br />IU <br />W <br />w <br />`z`'w <br />W� <br />.y <br />HNS <br />F <br />10 <br />9 <br />uj <br />a <br />a 0 <br />u <br />w <br />W <br />Nu <br />� <br />N B <br />r <br />Q <br />Q <br />� <br />C <br />QC <br />> <br />O <br />NOTE: <br />Project <br />EAGN DOOR TO B£ UNDERCUT A MINIMUM OF I/2-INCH TO ASSURE FREEFLOW <br />OF FRESH AIR THROUGHOUT HABITABLE ROOMS <br />Ur r) <br />1 71CITY <br />IT SheetNOTE: <br />j <br />REFER TO STRUCTURAL SHEETS FOR SHEAR WALL SCHEDULE AND <br />A <br />ENGINEERING PLAN WHICH CONTAIN REFERENCES AND/OR INSTRUCTIONS <br />PERTAINING TO EACH SHEAR WALL INDICATED IN THIS PLAN <br />