APPROVAL STAMPS <br /> GENERAL NOTES APPLICABLE CODES & REGULATIONS SCOPE OF WORK SHEET INDEX Permit#: FA2308-016 <br /> Site Address: 8407 Broadway <br /> Applicant: Charles Newton <br /> 1. IT IS THE INTENT THAT THE GENERAL NOTES INDICATED HERE BE APPLICABLE ONLY TO THE - 2021 INTERNATIONAL BUILDING CODE (IBC) (GO.01 BUILDING CODE INFORMATION) THIS PROJECT IS BEING SUBMITTED AS A CODE COMPLIANT FIRE ALARM SYSTEM WITH SPRINKLER SHEET # SHEET DESCRIPTION Application Date:08/16/2023 <br /> CONTRACTED SCOPE OF WORK INDICATED WITHIN THIS DRAWING PACKAGE. NOT ALL NOTES MAY APPLY MONITORING AND NOTIFICATION. INSTALL NEW MAIN FIRE ALARM CONTROL PANEL, FIRE ALARM ANNUNCIATOR, Description: Secure Space Everett Project <br /> TO THIS PROJECT. - 2018 INTERNATIONAL BUILDING CODE (IBC) FA0.01 SYSTEM INFORMATION, NOTES, LEGENDS <br /> NOTIFICATION APPLIANCES, MANUAL AND AUTOMATIC INITIATING DEVICES AND MONITORING / CONTROL Review Status: 1st Review by City&Peer Reviewers <br /> 2. THESE GENERAL NOTES SHALL NOT BE APPLICABLE TO ANY EXISTING CONDITIONS WITHIN THE FACILITY. 2018 INTERNATIONAL EXISTING BUILDING CODE QEBC INTERFACE DEVICES AS INDICATED WITHIN THIS SUBMITTAL PACKAGE. UPON COMPLETION A COMPLETE FAO.02 SEQUENCE, EQUIPMENT LIST & VOLTAGE DROP CALCULATIONS Review Date: 08/16/2023 <br /> ) PRETEST SHALL BE PERFORMED TO VERIFY FUNCTIONALITY. IF THE FUNCTIONALITY IS COMPLETE THEN THE <br /> I.E. EXISTING CONDITIONS FOUND TO BE PRESENT PRIOR TO THIS CONTRACT, WORK PREVIOUSLY FA1.00 SITE PLAN <br /> PERFORMED BY OTHER OR PREVIOUS SYSTEM CONTRACTORS, SEPARATE WORK UNRELATED TO THIS - 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) PROPER DOCUMENTATION SHALL BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION PRIOR TO <br /> SCHEDULING A FINAL INSPECTION. FA1.10 LEVEL 1 FIRE ALARM PLAN <br /> CONTRACT, SYSTEMS PREVIOUSLY APPROVED UNDER PAST CODES / REGULATIONS, ETC. Ev�rr `"`""� <br /> 2018 INTERNATIONAL MECHANICAL CODE (IMC) FAL20 LEVEL 2 FIRE ALARM PLAN ^^ <br /> 3. SIEMENS EQUIPMENT IS UNDERWRITERS LABORATORIES (UL) LISTED FOR POWER LIMITED INSTALLATION. THIS PROJECT INCLUDES THE FOLLOWING Everett Fire Dept.Permit Review <br /> 4. A STAMPED SET OF APPROVED PLANS SHALL BE ON THE JOB SITE AND USED FOR INSTALLATION. ANY - 2018 INTERNATIONAL FUEL GAS CODE (IFGC) - FIRE ALARM CONTROL UNIT FA1.30 LEVEL 3 FIRE ALARM PLAN Status:Approved <br /> DEVIATION FROM APPROVED PLANS, INCLUDING THE SUBSTITUTION OF DEVICES SHALL BE APPROVED BY - 2018 INTERNATIONAL FIRE CODE (IFC) - NOTIFICATION POWER SUPPLY (NAC) Reviewed By:KBrown <br /> FAIAO LEVEL 4 FIRE ALARM PLAN 08/16/2023 4:37:27 <br /> THE AUTHORITY HAVING JURISDICTION/ INSPECTOR OF RECORD. SIEMENS SHALL NOT BEAR ANY PM <br /> ADDITIONAL COST FOR RE-ENGINEERING AS A RESULT OF DEVIATIONS. - 2018 WASHINGTON STATE ENERGY CODE COMMERCIAL (WSEC) - REMOTE ANNUNCIATION AT NORMALLY ATTENDED LOCATION FA1.50 LEVEL 5 FIRE ALARM PLAN <br /> 5. ANY RACEWAY RUNS THAT ARE INDICATED WITHIN THIS DRAWING PACKAGE ARE SHOWN DIAGRAMMATICAL - 2018 WASHINGTON STATE ENERGY CODE RESIDENTIAL (WSEC) - MONITORING OF SPRINKLER SYSTEM ACTIVATION AND SUPERVISORY SWITCHES FA2.01 SYSTEM RISER DIAGRAM <br /> AND ARE FOR CIRCUITING PURPOSES ONLY. ALL RUNS SHOWN SHOULD NOT SERVE IN ANY WAY AS AN - MONITORING OF BACK-FLOW PREVENTOR SWITCHES FA3.01 FIRE ALARM CONTROL UNIT DETAILS & BATTERY CALCULATION <br /> ACTUAL ROUTING GUIDE FOR INSTALLATION OF RACEWAYS. EXACT INSTALL LOCATION SHALL BE FIELD - 2018 WASHINGTON STATE ENERGY CODE APPENDIX (WSEC) <br /> DETERMINED. FA5.01 DEVICE MOUNTING & WIRING DETAILS-1 <br /> AND <br /> 6. WIRING SHALL NOT BE LOOPED UNDER DEVICE TERMINALS. WIRE MUST BE CUT FOR IN AND OUT RUNS - 2018 UNIFORM PLUMBING CODE (UPC) - INTERFACE WITH ELEVATOR CONTROLS- RECALL, RECALL, FIREMAN'S HAT <br /> - INTERFACE WITH ELEVATOR SHUNT TRIP AND MONITORING SHUNT POWER FA5.02 DEVICE MOUNTING & WIRING DETAILS-2 <br /> PRIOR TO INSTALLING UNDER DEVICE TERMINALS. - 2018 NATIONAL FUEL GAS CODE (NFPA 54) <br /> 7. ELECTRICAL CONTRACTOR SHALL BE REQUIRED TO USE COLOR CODE AND/OR WIRE NUMBERS PER - SINGLE MANUAL PULL STATION AT APPROVED LOCATION <br /> CONTRACT DOCUMENTATION ON ALL WIRING. SUCH IDENTIFICATIONS SHALL BE MADE CONTINUOUS - 2018 LIQUEFIED PETROLEUM GAS CODE (NFPA 58) - AUDIBLE/VISUAL NOTIFICATION <br /> THROUGHOUT ALL CIRCUITS, CONNECTIONS, TERMINATIONS AND AT JUNCTION BOXES. - 2020 NATIONAL ELECTRICAL CODE (NFPA 70) Zt DEVICE INSTALLATION/OPERATING GUIDELINES Zt <br /> 8. WHERE SHIELDED CABLE IS USED, THE SHIELD SHALL BE CONTINUOUS AND GROUNDED ONLY ONCE AT <br /> THE RESPECTIVE CONTROL UNIT. - WAC 296-46B ELECTRICAL SAFETY STANDARDS, ADMINISTRATION, AND INSTALLATION PUBLIC MODE AUDIBILITY REQUIREMENTS 100'i <br /> THE UL LISTED OPERATING TEMPERATURE RANGE FOR ALL ADDRESSABLE DEVICES IS SIEMENS <br /> 9. T-TAPPING IS NOT ACCEPTABLE. - 2018 WASHINGTON STATE-WIDE AMENDMENTS FROM 32°F (0°C) TO 100^F (38°C). IF A DEVICE IS SHOWN IN AN AREA WHICH MAY <br /> 10, ALL 120VAC CIRCUITS FEEDING FIRE ALARM EQUIPMENT SHALL BE FROM A DEDICATED CIRCUIT MARKED 32 EXPERIENCE EXTREME COLD OR HEAT, CONTACT YOUR SIEMENS REPRESENTATIVE. <br /> AS 'FIRE ALARM', MARKED RED, AND PROVIDED WITH A BREAKER LOCK-ON DEVICE. - 2018 INTERNATIONAL SWIMMING Pool AND SPA CODE (ISPsc) a.a.3.1 Pueuc MODE AUDIBLE REOUIREMENrs <br /> 11. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANELS SHALL BE SUPERVISED TO THE PRINCIPAL - ICC A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES TO ENSURE THAT AUDIBLE PUBLIC MODE SIGNALS ARE CLEARLY HEARD UNLESS OTHERWISE FIRE ALARM EQUIPMENT SHALL NOT BE STORED OR INSTALLED IN AREAS EXPOSED TO SIEMENS INDUSTRY,INC. <br /> POINT OF ANNUNCIATION. (CONTROL UNITS) TO SUPERVISE ANNUNCIATOR PANEL(S), SUB-PANEL(S), PERMITTED BY 18.4.3.2 THROUGH 18.4.3.5, THEY SHALL HAVE A SOUND LEVEL AT LEAST 15 dB 15900 SE EASTGATE WAY <br /> - CITY OF EVERETT DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS FOR ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dB ABOVE THE ELEMENTS EXCEEDING NORMAL OPERATING CONDITIONS. LISTED WEATHERPROOF BELLEVUE,WA 98008 <br /> ALL CIRCUITS AND INITIATING DEVICES). DEVELOPMENT THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS DEVICES MAY BE INSTALLED AT EXTERIOR LOCATIONS PER MANUFACTURER 425.507.4300 <br /> 12. UNLESS OTHERWISE NOTED, ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT A MAXIMUM HEIGHT GREATER, MEASURED 5 FT (1.5M) ABOVE THE FLOOR IN THE AREA REQUIRED TO BE SERVED BY i /, INSTRUCTIONS. ALL OTHER DEVICES NOT SPECIFICALLY LISTED AS WEATHERPROOF 800.952.6348 24-HR SERVICE <br /> OF 48" ABOVE FINISHED FLOOR TO THE OPERABLE PART. - WASHINGTON STATE DEPT. OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN THE SYSTEM USING THE A-WEIGHTED SCALE (dBA) 'd'�;'i�;�/ /�, MUST BE INSTALLED IN SUITABLE LOCATIONS OR LISTED NEMA ENCLOSURES ( ) <br /> WASHINGTON APPLICABLE FOR THE ANTICIPATED ENVIRONMENT AND DEVICES TO BE INSTALLED. LICENSE:CC #SIEME11919PP <br /> 13. FIRE ALARM SIGNAL SHALL MEET ANSI S3.41, AUDIBLE EMERGENCY EVACUATION SIGNAL (TEMPORAL - EVERETT MUNICIPAL CODE (EMC) TABLE A.18.4.3 AVERAGE AMBIENT SOUND LEVEL ACCORDING TO LOCATION. <br /> PATTERN). FIRE ALARM AUDIBILITY SHALL BE NO LESS THAN 15db (PUBLIC MODE) OR 1OdB (PRIVATE (( �� THE INSTALLATION OF A FIRE ALARM SYSTEM AND ANY FIRE ALARM EQUIPMENT MUST <br /> LOCATION AVERAGE AMBIENT SOUND LEVEL (dBA) \\�()� This drawing and the information and design application <br /> MODE) ABOVE AMBIENT SOUND THROUGHOUT THE AREA OF ALARM. NOT BE INSTALLED NEXT TO OR WITHIN CLOSE PROXIMITY OF ANY RADIO FREQUENCY <br /> BUSINESS OCCUPANCIES 55 herein contained is the property of SIEMENS INDUSTRY, <br /> 14. WHERE MORE THAN TWO VISUAL APPLIANCES ARE IN THE SAME FIELD OF VIEW, THEY SHALL BE CENTRAL MONITORING STATION INFORMATION EQUIPMENT (EMI, RE, ME, HIGH OUTPUT, ETC.). SUCH INSTALLING CONDITIONS MAY INC. and is loaned upon the express condition that the <br /> EDUCATIONAL OCCUPANCIES 45 RF EMI some be returned to SIEMENS INDUSTRY, INC. upon <br /> SYNCHRONIZED IN ACCORDANCE WITH NFPA 72. INDUSTRIAL OCCUPANCIES 80 CAUSE UNDESIRABLE EFFECTS TO THE SYSTEM SUCH AS INTERMITTENT FAULTS, request; all information herein contained shall be treated <br /> INSTITUTIONAL OCCUPANCIES so IMPROPER SYSTEM OPERATIONS, FALSE ALARMS, ETC. as secret and confidential;shall <br /> reproduction of this <br /> 15. CEILING MOUNTED VISUAL NOTIFICATION APPLIANCES SHALL BE MOUNTED BELOW VISUAL OBSTRUCTIONS, MONITORING COMPANY: SIEMENS INDUSTRY INC <br /> MERCANTILE OCCUPANCIES 40 drawing or part thereof shall be mode without the written <br /> AND WHEN THESE APPLIANCES ARE MOUNTED ABOVE 10' A.F.F., THEY SHALL BE DERATED OR MECHANICAL ROOMS 85 consent of SIEMENS INDUSTRY, Incorporated. <br /> PROVIDED WITH PERFORMANCE-BASED ALTERNATIVE IN ACCORDANCE WITH NFPA 72. CENTRAL STATION UL N0.# 603961-026 PIERS AND WATER-SURROUNDED sTRucruREs 40 <br /> ENSURE EACH ADDRESSABLE DEVICE HAS BEEN PROPERLY PROGRAMMED PRIOR TO ITS <br /> PLACES of ASSEMBLY 55 INSTALLATION. DO NOT TERMINATE WIRES ONTO ADDRESSABLE DEVICES BEFORE IT HAS <br /> 16. IN ACCORDANCE WITH NFPA 72, DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION ADDRESS: 8600 NORTH ROYAL LANE, SUITE 100 RESIDENTIAL OCCUPANCIES 35 �` BEEN PROGRAMMED. <br /> CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY STORAGE FAR OCCUPANCIES 30 E <br /> THOROUGHFARES, HIGH-DENSITY URBAN 70 DELI <br /> HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED CITY / STATE / ZIP CODE: IRVING, TEXAS 75063 THOROUGHFARES, MEDIUM-DENSITY URBAN 55 <br /> PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED THOROUGHFARES, RURAL AND SUBURBAN 40 DO NOT REMOVE DUST COVERS FROM SMOKE DETECTORS UNTIL ALL CONSTRUCTION <br /> TELEPHONE NUMBER: TOWER OCCUPANCIES 35 <br /> 17. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER INSTALLATION INSTRUCTIONS (866) 552-7823 \ (877) 859-4135 UNDERGROUND STRUCTURES AND WINDOWLESS BUILDINGS 40 HAS BEEN COMPLETED. DUST COVERS WHICH HAVE BEEN REMOVED FROM ANY <br /> AND LISTINGS. MISAPPLICATION OF EQUIPMENT AND SUCH, VOIDS ALL WARRANTIES EITHER EXPRESSED FILE NO.: S7091 VEHICLES AND VESSELS 50 DETECTOR PRIOR TO THE FINAL CLEAN-UP OF ALL TRADES SHALL BE CLEANED OR <br /> OR IMPLIED WITH REGARDS TO LOSS, DAMAGE, LIABILITIES AND/OR SERVICE PROBLEMS. REPLACED, IN ACCORDANCE WITH NFPA 72. SIEMENS IS NOT RESPONSIBLE FOR <br /> 18. UNLESS NOTED OTHERWISE ALL WIRING AND INSTALLATION METHODS SHALL CONFORM TO APPLICABLE <br /> CON: UUFX FAULTS FOUND TO BE RELATED TO CONTAMINATION. <br /> ELECTRICAL CODE. MINIMUM SIZE OF 3/4" METALLIC RACEWAY SHALL BE INSTALLED. CHECK LIST FOR START UP TYPICAL CALLOUTS &ABBREVIATIONS I F, ALL INITIATING DEVICES (DETECTORS, PULL STATIONS, ETC.) AND NOTIFICATION <br /> 19. EFFORTS MUST BE PLACED ON MINIMIZING UNNECESSARY WIRE RUNS WITHIN DEVICE BACKBOXES. DO APPLIANCES (HORNS, STROBES, ETC.) MUST BE INSTALLED WITH BACKBOXES. THE <br /> NOT INSTALL WIRE WITHIN A BACKBOX THAT DOES NOT SERVE ITS CORRESPONDING DEVICE AND WHICH AC = ABOVE CEILING HT = HEIGHT EQUIPMENT SHOULD NEVER BE SUPPORTED WITH THE CIRCUIT WIRES. <br /> MAY INHIBIT ITS PROPER INSTALLATION. GOOD WIRING/INSTALLATION PRACTICES MUST BE ADHERED TO ALL = ABOVE FINISHED FLOOR ID = IN-DUCT MOUNTED <br /> AT ALL TIMES. THE FOLLOWING IS A LIST OF CRITERIA THAT MUST BE MEET PRIOR TO START UP AHJ = AUTHORITY HAVING JURISDICTION IDC = INITIATING DEVICE CIRCUIT <br /> 20. AS FIELD CONDITIONS DICTATE ACTUAL RACEWAY INSTALLATIONS, DEVICE BACK BOXES AND JUNCTION AHU = AIR HANDLING UNIT MAX = MAXIMUM THE USE OF MAGNETS FOR THE PURPOSE OF TESTING DETECTORS FOR INITIATION OF <br /> BOXES SHALL BE SIZED PER FIELD INSTALLING CONDITIONS. DEVICE BACK BOX SIZES INDICATED WITHIN <br /> ❑ MARK-UP THE SIEMENS FIRE SAFETY SHOP DRAWINGS, SHOWING THE ACTUAL WIRE RUNS. NOTE THAT ANN = ANNUNCIATOR MIN = MINIMUM AN ALARM IS STRICTLY PROHIBITED. TESTING WITH A MAGNET DOES NOT SATISFY NFPA <br /> THIS DRAWING PACKAGE ARE MINIMUM REQUIREMENTS ONLY. AN INCREASE IN BACK BOX DEPTH, ANY DISCREPANCIES/CHANGES BETWEEN THE ACTUAL CONDITIONS AND THE SYSTEM DRAWINGS SHOULD CMS = BUILDING MANAGEMENT SYSTEM N = NEW 72 TEST METHOD REQUIREMENT OF 'SMOKE ENTRY INTO THE SENSING CHAMBER', AND g <br /> ADDITION OF EXTENSION BOX/RING, ETC. MAY BE REQUIRED IN ORDER TO PROPERLY ACCOMMODATE BE NOTED FOR INCLUSION ON THE FINAL RECORD DRAWINGS. C = CEILING MOUNTED N/A NOT APPLICABLE MAY CAUSE UNDESIRABLE EFFECTS TO THE DETECTOR. <br /> "C = CONDUIT (CIRCULAR RACEWAY) NAC = NOTIFICATION APPLIANCE CIRCUIT <br /> FOR WIRE QUANTITIES INSTALLED WITHIN THE RACEWAY. CD (i.e., 15CD) CANDELA NIC NOT IN CONTRACT THE PAINTING OR MODIFYING OF ANY FIRE ALARM EQUIPMENT IS STRICTLY PROHIBITED <br /> = = <br /> 21. THE INSTALLATION OF DEVICE BACKBOXES & WIRE SHALL BE SIZED AND INSTALLED PER APPLICABLE El ALL DEVICES HAVE BEEN INSTALLED AND TERMINATED PROPERLY. AND SHOULD NOT BE PERFORMED UNDER ANY CIRCUMSTANCES. <br /> OEM = CUBIC FEET PER MINUTE (AIRFLOW) NTS = NOT SCALE <br /> ELECTRICAL CODE. IN ADDITION SUCH BOXES & WIRE SHALL BE INSTALLED IN A MANNER AS TO CKT CIRCUIT PS = POWER SUPPLY <br /> ALLOW FOR THE EASE OF DEVICE INSTALLATION & FUTURE MAINTENANCE. THE INSTALLATION OF ❑ CONTACTED SIEMENS FIRE SAFETY PROJECT MANAGER 14 DAYS PRIOR TO SCHEDULED START UP. CSFD = COMBINATION SMOKE FIRE DAMPER RA = RETURN-AIR GRILL MOUNTED <br /> DEVICES WHICH REQUIRE EXCESSIVE FORCE OR THE PINCHING OF WIRES IN ORDER TO PROPERLY SEAT DACT = DIGITAL ALARM COMM. TRANSMITTER RL = RELOCATED DEVICE <br /> THE DEVICE TO ITS FINISHED SURFACE MAY RESULT IN GROUND FAULTS OR OTHER SYSTEM TROUBLES, DR DROP & RE-HANG EXISTING RR = REMOVE EXISTING, REPLACE w/ NEW DEVICE NUMBERING LEGEND <br /> AND SHALL BE CONSIDERED AN UNACCEPTABLE INSTALLATION STANDARD. ❑ ALL FIELD DEVICES INCLUDING DETECTORS, MODULES, NOTIFICATION APPLIANCES BOTH VISUAL AND <br /> = = <br /> AUDIBLE ARE ADDRESSED AND OUTPUT SET (AS REQUIRED) AND INSTALLED. E EXISTING SF DEVICE MOUNTED IN SUB-FLOOR ADDRESSABLE ALARM INITIATING DEVICES ALARM NOTIFICATION APPLIANCE <br /> 22. DO NOT APPLY POWER TO CONTROL UNIT(S) UNTIL SIEMENS AUTHORIZED PERSONNEL HAVE VERIFIED EL = ELEVATOR RECALL SLC = SIGNALING LINE CIRCUIT EXAMPLE: EXAMPLE: <br /> THE SYSTEM INSTALLATIONS. UPON SATISFACTORY COMPLETION OF THEIR INSPECTION, POWER WILL BE FOIL = END OF LINE TBD = TO BE DETERMINED c c 0 75CD-CANDELA RATING <br /> ❑ -APPLIED TO THE CONTROL UNIT(S). SIEMENS ASSUMES NO LIABILITY FOR ANY DAMAGE TO THE IF YOUR SYSTEM IS BEING FURNISHED WITH A DIALER, APPLICABLE AMOUNT OF RJ31X PHONE JACKS EPO = EMERGENCY POWER OFF TYP = TYPICAL O L1.030 DEVICE ADDRESS 0/ 4V3.2-4 <br /> EQUIPMENT SUPPLIED IF POWER IS APPLIED TO THE CONTROL UNIT(S) PRIOR TO INSPECTION OF THE MUST BE INSTALLED WITHIN 3 FEET OF THE MAIN FIRE ALARM CONTROL UNIT. THESE PHONE LINES ER = EXISTING TO BE RELOCATED OF = UNDER-FLOOR <br /> _LL' <br /> INSTALLATION BY SIEMENS AUTHORIZED PERSONNEL. MUST BE CONNECTED BEFORE ALL BUILDING PHONE EQUIPMENT (NO "9" PREFIX), AND SHOULD HAVE FAA = FIRE ALARM ANNUNCIATOR UON = UNLESS OTHERWISE NOTED DEVICE INDICATES DEVICE ADDRESS DEVICE SYMBOL INDICATES DEVICE NUMBER <br /> NO DIAL-OUT RESTRICTIONS. PROVIDE THE SIEMENS PROJECT MANAGER WITH A CUSTOMER EMERGENCY FACP = FIRE ALARM CONTROL PANEL WM = DEVICE WALL MOUNTED SYMBOL INDICATES LOOP NUMBER INDICATES CIRCUIT NUMBER <br /> 23. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES, EXACT INDICATES RPS#OR PANEL& <br /> ROUTING OF THE CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO CALL LIST. IF MONITORING NOT PROVIDED BY SIEMENS, THEN FOLLOWING INFORMATION MUST ALSO BE FACU = FIRE ALARM CONTROL UNIT WP = WEATHERPROOF ABOVE EXAMPLE MEANS: <br /> OBTAINED PRIOR TO START UP: CENTRAL STATION ACCOUNT NUMBER, RECEIVER PHONE NUMBERS, FATC = FIRE ALARM TERMINAL CABINET X = DEMO EXISTING CKT TYPE <br /> SUIT CONDITIONS. ALL THE CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. ABOVE EXAMPLE MEANS: 75CD STROBE HORN STROBE, PANEL 4V3, CIRCUIT 2, <br /> CENTRAL STATION VOICE LINE NUMBER, AND ALARM COMPANY PHONE NUMBER. FBO = FURNISHED BY OTHERS XP = EXPLOSION PROOF SMOKE DETECTOR, LOOP 1, DEVICE ADDRESS 30 / <br /> 1 24. CABLE INSTALLED IN UNDERGROUND RACEWAYS OR OTHER WET LOCATIONS SHALL BE RATED/LISTED ESE = FIRE SMOKE DAMPER DEVICE 4 <br /> 11 FOR WET LOCATIONS. ❑ CHECK HERE IF NOT APPLICABLE DEVICE CONDUIT WIRING GUIDELINE <br /> 25. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION <br /> NSTRUCTIONS. INSTALLATION GUIDELINES: DEVICE BACKBOXES SHOULD NOT CONTAIN WIRE THAT DOES NOT SERVE ITS <br /> CHECK FIELD WIRING WITH AN OHM METER: CABLE LEGEND ASSOCIATED DEVICE. TO PREVENT BACKBOX OVERFILL & IMPROPER DEVICE INSTALL, ALL EFFORTS MUST <br /> BE MADE TO PREVENT UNNECESSARY WIRE FILL WITHIN DEVICE BACKBOXES. MOUNTING SPECIFICATIONS <br /> ALL FIRE ALARM CIRCUITS SHOULD BE COMPLETED AND TESTED BEFORE THE ARRIVAL OF THE FIRE ALARM CABLE TYPE DRY LOCATION CIRCUIT <br /> if BUILDING/PROJECT INFORMATION AUTHORIZED PERSONNEL. CIRCUITS MUST BE FREE OF OPENS, SHORTS, AND GROUND FAULTS BEFORE DESIGNATION OPEN CABLE IN CONDUIT WE LOCATION DESCRIPTION INDICATED WITHIN THE EQUIPMENT & DEVICE LEGEND ARE MINIMUM RECOMMENDATIONS. JUNCTION <br /> BEING CONNECTED TO THE SYSTEM. CIRCUITS SHOULD HAVE END OF LINE RESISTORS INSTALLED BEFORE 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR 2-COND q16 TWISTED PAIR BOXES, EXTENSION RINGS, ETC. MUST BE INSTALLED AS NEEDED AND AS FIELD CONDITIONS DICTATE. <br /> BUILDING OCCUPANCY: S-1 TESTING THEM. A WRITTEN CONFIRMATION SHALL BE PROVIDE TO SIEMENS BY THE INSTALLER * FLOOR PLAN EXAMPLE EXAMPLE DEFINED: <br /> SOLID FPL CABLE SOLID FPL CABLE FPL CABLE (SLC) LOOP 1A,4B,2C1D 1A,4B,2C1D 1A,4B,2C,1D 1A,4B,2C,1D 1A,4B,2C,1D 1A,4B,2C,1D <br /> ACKNOWLEDGING ALL CIRCUITS HAVE BEEN TESTED. ADHERENCE TO THIS PRACTICE WILL SAVE TIME AND A WEST PENN #AQ225 OR <br /> SPRINKLERS: YES MONEY FOR ALL CONCERNED PARTIES. IF IT IS A NAC CIRCUIT, THE RESISTOR IS WITH THE EQUIPMENT THAT EQUIVALENT ADDRESSABLE � ���« J J <br /> CONSTRUCTION TYPE: -A, II-B CONTROLS THAT CIRCUIT. RED JACKET-RED BLACK RED JACKET-RED BLACK RED JACKET-RED BLACK 15CD C zB,zc O 2A* 2 _WHERE T-TAPPING <br /> 2-COND #14 TWISTED PAIR 2-COND #14 TWISTED PAIR 2-COND14 TWISTED PAIR 15CD C S ALLOWED,THIS CAN <br /> NUMBER OF STORIES: 5 STORIES + 1 ROOF AGROUND FAULT IS A CONDUCTOR THAT IS CONNECTED TO GROUND. THEY CAN OCCUR FROM SKINNED P STRANDED FPL* CABLE STRANDED FPL* CABLE FPIFWEST PENN A BE 1A IN CLASS B <br /> INSULATION OR INTERNAL DEVICE FAILURES. FIRE ALARM SYSTEMS MONITOR BOTH THE POSITIVE AND #Q226 OR 24VDC POWER DEPICTION OF A DIAGRAMMATICAL INSTALL SHOWN ON FLOOR PLAN ACTUAL FIELD INSTALLATION SLC CIRCUITS AGENCY REFERENCE: <br /> NEGATIVE CONDUCTORS FOR SHORTS TO GROUND. SHORTS CAN BE DETECTED BY USING A CONTINUITY EQUIVALENT <br /> SQUARE FOOTAGE OF PROJECT: ESTIMATED 101,820 SO. FT. RED JACKET-RED BLACK RED JACKET-RED BLACK RED JACKET-RED BLACK VICINITY MAP <br /> DETECTOR OR AN OHMMETER. SIMPLY CONNECT ONE LEAD OF YOUR METER TO A GOOD GROUND SOURCE <br /> AND THE OTHER TO THE CONDUCTOR YOU ARE TRYING TO TEST. THE METER SHOULD GIVE AN INDICATION 2-COND #12 TWISTED PAIR 2-COND #12 TWISTED PAIR 2-COND #12 TWISTED PAIR <br /> �I OF AN OPEN IF THE CIRCUIT IF FREE FROM A FAULT. MEG OHM GROUND FAULTS MAY INDICATE THE V STRANDED FPL* CABLE STRANDED FPL* CABLE WES CPBNN #AQ227 OR (NAC) VISUAL <br /> CIRCUIT INFORMATION PRESENCE OF WATER IN CONTACT WITH SYSTEM WIRING. ALL SYSTEM FIELD WIRING MUST BE FREE OF EQUIVALENT CIRCUIT _ o <br /> GROUNDS AND SHORTS, BEFORE THE START UP. RED JACKET-RED BLACK RED JACKET-RED BLACK RED JACKET-RED/BLACK r <br /> INITIATING DEVICE CIRCUIT (IDC): CLASS B 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR v <br /> ❑ MEASURE EACH CONDUCTOR OF THE ADDRESSABLE LOOP (SLC) TO GROUND, CONDUCTOR TO STRANDED OR SOLID FPL* STRANDED OR SOLID FPL* FPL CABLE ® 9 <br /> SIGNALING LINE CIRCUIT (SLC): CLASS B CONDUCTOR, CONDUCTOR TO SHIELD, AND SHIELD TO EARTH. THE RESISTANCE SHOULD BE GREATER X WEST PENN #AQ225 OR AUXILIARY <br /> ( ) CABLE CABLE # CONNECTION <br /> THAN 1 MEGA OHM. NOTE LINE TO LINE MEASUREMENTS REQUIRE ONE END OF THE PAIR TO BE EQUIVALENT © 00 08/08/23 ISSUED FOR PERMIT APK <br /> NOTIFICATION APPLIANCE CIRCUITS (NAC): CLASS B SHORTED, STRAY VOLTAGES SHOULD BE LESS THAN 1 VDC/AC, RECORD THE READINGS. RED JACKET-RED BLACK RED JACKET-RED BLACK RED JACKET-RED BLACK No DATE REMARKS Nn <br /> 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR DRAWN: APK <br /> PATHWAY SURVIVABILITY: LEVEL 1 ❑ MEASURE EACH CONDUCTOR OF THE NOTIFICATION APPLIANCE CIRCUIT NAC TO GROUND, AND SOLID FPL* CABLE SOLID FPL* CABLE FPL CABLE (IDC) <br /> (NAC) Z WEST PENN #AQ225 OR CONVENTIONAL CHECKED: GN <br /> CONENDDOFTONETRESOSNORC STRAYTHE VOLTAGESTANCE SHOULD BECESS THAN BE TIR THAN VDC/AC, MEGA OHM, WITHOUT THE RED JACKET-RED BLACK RED JACKET RED BACK RQUIVALENT ED JACKET-RED/BLACK INITIATION ZONE m <br /> SHEET DESCRIPTION: <br /> I CONTRACTOR INFORMATION 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR FIRE ALARM SYSTEM <br /> SOLID FPL* CABLE SOLID FPL* CABLE FPL CABLE ;_ip SYSTEM INFORMATION,NOTES, <br /> 8 CONTRACTOR: KIRBY ELECTRIC INC ❑ MEASURE ACROSS THE CONDUCTORS OF A NOTIFICATION APPLIANCE CIRCUIT(NAC), YOUR READING AN WEST PENN #AQ225 OR ANNUNCIATOR LEGENDS <br /> ADDRESS: 4826 B ST NW SHOULD BE EQUIVALENT TO THE VALUE OF THE END OF LINE RESISTOR INSTALLED AT THE LAST DEVICE. EQUIVALENT COMMUNICATION 8 �,... VN•t. _ <br /> AUBURN, WA 98001-1752 1RED JACKET-RED BLACK I RED JACKET-RED BLACK I RED JACKET-RED BLACK <br /> IF THE MEASUREMENTS ARE NOT WITHIN THE ACCEPTABLE VALUES, THEN THE CIRCUIT WIRING HAS A SHORT, THE ABOVE REFERENCED IS THE RECOMMENDED WIRE TYPE TO BE UTILIZED. WIRE SUBSTITUTIONS OF A SIMILAR TYPE AND <br /> E OPEN, OR GROUND FAULT, AND IS NOT READY FOR START UPI ;E° JOB NUMBER: <br /> y CONTRACTOR JOB #: 23-020 OF A LIKE NATURE MAY BE UTILIZED. THE USE OF ALTERNATE WIRE TYPES MUST BE ACCEPTED BY THE AHJ AND MEET THE 440P-360662 <br /> = SAME CRITERIA, SPECIFICATIONS, LISTINGS, ETC. AS THE ABOVE WIRE INDICATED. <br /> CONTACT PERSON: JOSH STEFOGLO CONDUIT WIRE FILL CHART - PROPER USE OF LISTED FPL/FPLR/FPLP CABLE SHALL BE USED IN APPLICABLE INSTALLATION PER ELECTRICAL CODE. - <br /> PHONE #: (253)859-2000 ELECTRICAL FLEXIBLE METALLIC RIGID METALLIC FLEXIBLE LIQUIDTIGHT PROJECT NAME ADDRESS: <br /> i THIS PROJECT TO BE INSTALLED AS A CONDUIT INSTALLATION. PROVIDE REQUIRED SUPPORTS SPACED IN ACCORDANCE <br /> METALLIC CONDUIT CONDUIT CONDUIT METALLIC CONDUIT SECURE SELF STORAGE-EVERETT EXPANSION <br /> WITH APPLICABLE ELECTRICAL CODE. PROVIDE CONDUIT OR OTHER RACEWAY WHERE REQUIRED BY CODE FOR PROTECTION <br /> CONDUIT INTERNAL *MAXIMUM INTERNAL *MAXIMUM INTERNAL *MAXIMUM INTERNAL *MAXIMUM BROADWAY EVERETT SELF STORAGE <br /> N SIEMENS CONTACT INFORMATION TRADE SIZE DIAMETER FILL-407 DIAMETER FILL-407 DIAMETER FILL-407 DIAMETER FILL-407 OF WIRING/CIRCUITS. WHERE CONDUIT IS USED, SIZE ACCORDINGLY TO THE CONDUIT FILL CHART AND APPLICABLE SCOPE OF WORK 8407 BROADWAY <br /> PROJECT MANAGER: CHARLES NEWTON 3/4" 0.8240 0.2130 0.8240 0.2130 0.8360 0.2200 0.8300 0.2160 ELECTRICAL CODE. \ EVERETT,WA98208 <br /> EMAIL: charles.newton-iii@siemens.com 1" 1.0490 0.3460 1.0200 0.3270 1.0630 0.3550 1.0540 0.3490 EXAMPLE: NUMBER OF CONDUCTOR PAIRS BROADWAY EVERETT SELF STORAGE <br /> 1 1/4" 1.3800 0.5980 1.2750 0.5110 1.3940 0.6100 1.3950 0.6110 WIRE TYPE DESIGNATION NORTH 8407 BROADWAY DRAWING <br /> M SALES EXECUTIVE: SEAN MULLEN 1 1/2" 1.6100 0.8140 1.5380 0.7430 1.6240 0.8290 1.5880 0.7920 NUMBER: ��O■0 <br /> PHONE 425 229-1590 2" 2.0670 1.3420 2.0400 1.3070 2,0830 1.3630 2.0330 1.2980 MDAUIc RACEWAY/OPEN aBLE/P LNUM CABLE/Ec.(WHERE APPLICABLE) <br /> # ( ) � EVERETT, WA 98208 <br /> EMAIL: sean.mullen@siemens.com * UNIT MEASUREMENTS INDICATED UNDER 40% MAXIMUM FILL REPRESENT SQUARE INCHES. ABOVE EXAMPLE "2A" MEANS "2 TWISTED PAIR CABLES" ALL WIRE AND CABLE TO BE SIGNED,TYPED AND CONDUIT FILL <br /> FOR REFERENCE ONLY - RECOMMENDATION FOR CONDUIT SIZE PER N.E.C. PER ELECTRICAL CODE AND MANUFACTURER'S RECOMMENDATION. 0 <br /> SHEET SIZE:PRCH El-30x42 <br />