Laserfiche WebLink
APPROVAL STAMPS <br /> SEQUENCE OF OPERATIONS EQUIPMENT LIST <br /> 01 FIRESTOP DETAIL - GYPSUM STUD WALL <br /> NOT TO SCALE-SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION FACU COMPONENTS ALL PARTS ARE SIEMENS <br /> UNLESS OTHERWISE NOTED <br /> SYMBOL STY MODEL DESCRIPTION *ROUGH IN <br /> A 1 3 Control Unit Required Fire Safety NUMBER <br /> Building Sequence of Operations Notification FACU 01 FC2025-US DESIGO 252-POINT KIT INCLUDES: (1)FCM2018-U2 OPERATOR INTERFACE, INTERNAL PANEL <br /> 3 Annunciation Control S54400-C4-Ai (1)FP2011-Ul 170W POWER SUPPLY,(1)FC12016-Ul PERIPHERY BOARD COMPONENT <br /> System and <br /> W-L Items FHB2002-Ul-2-HEIGHT UNIT(2HU)BACK BOX,BLACK <br /> F Ratings-t 2,3 and and(See Items 2 and 3) FHK2002-U2 FHD2002-U2-2-HEIGHT UNIT 2HU OUTER DOOR w 1 WINDOW,BLACK SEMI-FLUSH OR <br /> T Ratings-0,1,2,3, d 4 Hr(See Item 3) Ul ( ) / <br /> L Rating At Ambient-Less Than 1 CFM/sq ft * 554400-051-A1 FHD2004-U1-INNER DOOR,BLACK SURFACE MOUNT <br /> L Rating At 400 F-Less Than 1 CFM/sq ft * C FHD2006-Ul-CLEAR-LENS WINDOW <br /> 2 W <br /> __10E O O 00 S * 01 FHD2005-U1 INNER DOOR,SOLID BLACK INTERNAL PANEL <br /> ca .-. S54400-B53-A1 COMPONENT <br /> yA 1B FCA2016-U1 INTERNAL PANEL <br /> f0 - 01 IRS <br /> INTERFACE BOARD <br /> LO LLI _ O U 554400-A39-Ai COMPONENT <br /> J U C O U N J "A" -U1 INTERNAL PANEL <br /> W -O O O O O N 01 DIGITAL ALARM COMMUNICATOR TRANSMITTER <br /> SECTION A-A J N C C _ U N 554400-A63-A1 COMPONENT <br /> 1.Wall Assembly-The 1,2,3 or 4 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the To C IN Q C IT CE i O3 A7300 6 INTERNAL PANEL <br /> W 7 r0 02 BATTERY 12 VOLT 18 AMP HOUR <br /> w N O C A7F30026428 COMPONENT <br /> manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include N N 7 V lD 'O E <br /> the following construction features: N C N O « rn p SURGE 01 CP2341 SURGE SUPPRESSOR-120 VAC FIELD VERIFY <br /> A.Studs-Wall framing may consist of either wood studs(max 2 Er fire rated assemblies)or steel channel studs.Wood studs to consist N o N O to (Q CL (a <br /> of nom 21 4 in.(51 by 102 mm)lumber spaced 16 in.(406 mm)OC with nom 2 by 4 in.(51 by 102 mm)lumber end plates and (p 0) 2 N <br /> ass braces.Steel studs to be min 3-5/8 in.(92 mm)wide by 1-3/8 in.(35 mm)deep channels spaced max 24 in.(610 mm)OC W- Elevator recall to primary or alternate floor and > W C C U C <br /> B.Gypsum Board*-Nom 1/2 or 5/8 in.(13 or 16 mm)thick 4 ft.(122 cm)wide with square or tapered edges.The sum wallboard 'J O C O <br /> YP q P 9 9YP CE D] V O N N N <br /> type,thickness,number of layers,fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Visual Warning (Firefighter Hat) shall be W N O e U) e C v U o L) <br /> Design in the UL Fire Resistance Directory.Max diam of opening is 26 in.(660 mm). (D O } ,O C ,O (Q O O ALL PARTS ARE SIEMENS <br /> performed by the elevator controller per the Q a O m E ANNUNCIATOR COMPONENTS <br /> 2.Through Penetrant-Nom 1/2 or 5/8 in.(13 or 16 mm)thick 4 ft.(122 cm)wide with square or eccentrically within the firestop J � (Z' w C (p 0 (p (O O > > (ll UNLESS OTHERWISE NOTED <br /> system.The annular space between pipe,conduit or tubing and periphery of opening shall be min of 0 in.(0 mm)(point contact)to max Elevator Code AS M E A17.1 Q U) G7 C U o U Lu U 1n > > o `o <br /> 2 in.(51 ni Pipe,conduit or tubing to be rigidly supported on both sides of wall assembly.The following types and sizes of metallic +� �, �, m O (n O O '> C >s MODEL <br /> es,conduits or Lubin a be used: c c O W N O SYMBOL STY DESCRIPTION ROUGH IN <br /> pip tubing E 2i -p > -p J -O 70 30 m3 NUMBER SIEMENS <br /> A.Steel Pipe-Nom 24 in.(610 mm)diam(orsmaller)Schedule 10(or heavier)steel pipe. > > O E ) 1) m � O N a N +- FT2015-U2 <br /> B.Iron Pipe-Nom 24 is(610 mm)diam(orsmaller)Schedule 10(or heavier)steel pipe.pipe,nom 12 is(305 mm)diam(orsmaller) O O O O C W C C (6 O !� ANN 02 554400-F68-A1 REMOTE DISPLAY TERMINAL w/CONTROL 4S DEEP BOX <br /> or Class 50(or heavier)ductile iron pressure pipe. CE C C (O g N 0 l=11 "U "U O <br /> C.Conduit-Nom 6 in.(152 mm)diam(or smaller)steel conduit or nom 4 in.(102 mm)diam(or smaller)steel electrical metallic O O O U Q Q Q Q - m a O O > Cu <br /> tubing. U U U ..+ ..+ ..+ N N N N O C O <br /> D.Copper Tubing-Nom 6 in.(152 mm)diam(or smaller)Type L(or heavier)copper tubing. N N N 'U 7 7 7 0) = r- t9 f6 N -� (O SIEMENS INDUSTRY,INC. <br /> is c E o E o E o - - N > ALL PARTS ARE SIEMENS 15900 SE EAST <br /> GATE WAY <br /> E.Copper Pipe-Nom6 in.(152 mm)diam(or smaller)Regular(or heavier)copper pipe. > > > 0 _ _ _ _ > -0 w F5 03 v REMOTE POWER SUPPLY COMPONENTS UNLESS OTHERWISE NOTED <br /> F.Through Penetrating Product--Flexible Metal Piping-The following types of steel flexible metal gas piping maybe used: U U U (1) 0 (1) a) L 0) W BELLEVUE,WA 98008 <br /> L) C <br /> 1. Nom 2 in.(51 mm)diam(or smaller)steel flexible metal gas piping.Plastic covering on piping mayor may not be removed on both System Inputs Q Q Q Q H H Q (n (n Z Of Of SYMBOL QTY MODEL DESCRIPTION *ROUGH IN 425.507.4300 <br /> sides of floor or wall assembly. - NUMBER 800.952.6348(24-HR SERVICE) <br /> OMEGA FLEX INC Manual fire alarm box X X X X X PAD-5-6A ADDRESSABLE POWER SUPPLY NOTIFICATION APPLIANCE EXTENDER-6A <br /> Z Nam 1 in.(25 mm)diam(orsmaller)steel flexible metal Plastic covering t be removed on both PADS 03 S54339-A15-A1 (INCLUDES PAB-ENCL,PAD-5-MB,FP2011-U1) SURFACE MOUNT LICENSE:CC #SIEME11919PP <br /> gas piping. gon piping may or may no Smoke detector above FA panel X X X X X <br /> sides of floor or wall assembly. PS-1270 <br /> 06 BATTERY 12 VOLT 7 AMP HOUR INSIDE PAB-ENCL <br /> GASTITE,DIV OF TITLEFLEX A7F30026424 This drawing and the information and design application <br /> 3.Nom 1 in.(25 mm)than(orsmaller)steel flexible metal gas piping.Plastic covering on piping mayor may not be removed on both Elevator lobby smoke detector-main floor X X X X X X SURGE 01 CP2341 SURGE SUPPRESSOR-120 VAC FIELD VERIFY herein contained is the property of SIEMENS INDUSTRY, <br /> sides offloororwall assembly. INC. and is loaned upon the express condition that the <br /> WARD MFG LLC Elevator lobby smoke detector-all other floors X X X X X X some be returned to SIEMENS INDUSTRY, INC. upon <br /> 3.FiII,Voiof or Cavity Material*-Caulk or Sealant-Min 5/8.1-1/4,1-7/8 and 2-1/2 in.(16,32,48 and 64 mm)thickness of caulk for 1,2, request; all information herein contained shall be treated <br /> 3 and 4 hr rated assemblies,res rivet,a lied within annulus,flush with both surfaces of wall.Min 1/4 in.(6 mm)diam bead of caulk Elevator machine room @ main floor smoke det X X X X X X X as secret and confidential; no reproducton of this <br /> Pec Y pP drawing or part thereof shall be made without the written <br /> applied to gypsum board/penetrant interface at point contact location on both sides ofwall.The hourly F Rating of the firestop system Elevator machine room smoke detector X X X X X X X consent of SIEMENS INDUSTRY, Incorporated. <br /> is dependent upon the hourly fire rating of the wall assembly in which it is installed,as shown in the following table.The hourly T Rating ALL PARTS ARE SIEMENS <br /> of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which Elevator machine room heat detector X X X X X Xx INITIATING DEVICE COMPONENTS UNLESS OTHERWISE NOTED <br /> it is installed,as tabulated below: <br /> Max Pipe or Elevator hoistway smoke detector X X X X X X X SYMBOL QTY MODEL DESCRIPTION *ROUGH IN <br /> Conduit Diann in. F Rating Hr T Rating Hr NUMBER <br /> (mm) Elevator hoistway heat detector X X X X X X X FD0421 <br /> 1(25) 1 or 0+,1 or °� 17 S54320-F4-A1 INTELLIGENT PHOTOELECTRIC SMOKE DETECTOR HEAD DB-11 <br /> 1(25) Oro or4 Elevator120VAC shunt trip circuit failure X X X <br /> 4(102) 1 or 0 DB-11 4S DEEP BOX w/ <br /> 6(152) or 17 500-094151 DETECTOR BASE 1-GANG RING <br /> 12(305) 1 or 0 Sprinkler water flow switch X X X X X FDT421 <br /> +When copper pipe is used,T Rating is 0 hr. *® 04 S54320-F5-A1 INTELLIGENT HEAT DETECTOR HEAD DB-11 <br /> 3M COMPANY-CP 25WB+caulk or FB-3000 WT sealant Sprinkler valve supervisory switches X X X DB-11 4S DEEP BOX w/ <br /> 'Bearing the UL Classification Marking 04 500-094151 DETECTOR BASE 1-GANG RING <br /> FACU 120VAC power failure X X X DM 07 MRI-D INTELLIGENT DUAL INPUT MONITOR MODULE 4S DEEP BOX <br /> S54370-32-Ai <br /> Remote power supply trouble(power,wiring) X X X RM 08 MRI-R INTELLIGENT CONTROLLABLE RELAY w/SINGLE INPUT MONITOR MODULE 4S DEEP BOX <br /> System device trouble X X X S54370-Bl-AI <br /> �2 NOT TO SCALE <br /> DETAIL - CONCRETE FLOOR OR WALL © 01 XMS-S INTELLIGENT MANUAL PULL STATION 4S DEEP BOX w/ <br /> L --SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION System wiring trouble(ground, open, short) X X X S5432147-A1 SINGLE ACTION,KEY RESET 1-GANG RING <br /> ❑M 03 MRI-S INTELLIGENT SINGLE INPUT MONITOR MODULE 4S DEEP BOX <br /> S54370-B3-A1 <br /> IR 02 RIEUIC FUNCTIONAL DEVICES MULTI-VOLTAGE RELAY-24VDC,24VAC,120VAC COIL 4S DEEP BOX <br /> 2 4 1 <br /> A 4 <br /> Building BRmote Po EVERETT SELF-STORAGE STORAGE Building BRmote Po rSupplTSELF-STORAGE NOTIFICATION DEVICE COMPONENTS ALL PARTS ARE SIEMENS <br /> System No.C-AJ-1044 Panel#Remote Power Supply 1V1 Panel#Remote Power Supply 1V2 UNLESS OTHERWISE NOTED <br /> F Ratings-2,3,and 4 Hr(See Items 2A and 4) Panel Location ELECTRICAL ROOM-103 Panel Location ELECTRICAL ROOM-103 <br /> T Rating-0 Hr BATTERY SIZING CALCULATION 8/5f2023 BATTERY SIZING CALCULATION 8/5/2023 MODEL <br /> L Rating At Ambient-2 CFM/sgft '" Device Q, Standby Total StandbyAlarm Total Alarm Device Standby Total Stand Alarm Total Alarm SYMBOL QTY NUMBER DESCRIPTION *ROUGH N <br /> L Rating At 400 F less than 1 CFM/sq ft '"xS <br /> W Rating-Class I(See Item 4) l� " + Main Board Main Board 15 SLHSCW-F MULTI-CANDELA HORN/STROBE,CEILING MOUNT-WHITE <br /> PAD5-6A 1 0.078 0.078 0.174 0.174 PAD5-6A 1 0.078 0078 0.174 0.174 C9g 102 554329-F13-A1 FIELD SELECTABLE 15/30/75/95cd 4S DEEP BOX <br /> 2 3 Circuits Circuits ISp SLSCW-F MULTI-CANDELA LED STROBE,CEILING MOUNT-WHITE <br /> A 1v1.1 9 - - - 0 396 1V2.1 13 - - - 0.572 5S 02 S54329415-Ai FIELD SELECTABLE 15/30/75/95cd 4S DEEP BOX <br /> 1V1.2 9 - - - 0.430 1V2.2 13 - - - 0.572 <br /> SECTION A-A 1V1.3 11 - - - 0.484 1V2.3 12 - - - 0.528 <br /> 1 Vl.4 10 0.440 1 V2.4 10 0.440 <br /> Standby Current Alarm Current Standby Current _ Alarm Current MISCELLANEOUS DEVICES ALL PARTS ARE SIEMENS <br /> 0 1.Floor or Wall Assembly-Lightweight or normal weight(100-150 pcf or 1600-2400 kg/m3)concrete.Except as noted in table under Standby Current 0.078 Amps 0.078 1.924 Standby Current 0.078 Amps 0.078 _ 2.286 UNLESS OTHERWISE NOTED <br /> Item 4,min thickness of solid concrete floor or wall assembly is 4-1/2 in.(114 mm).Floor may also be constructed of any min 6 in.(152 Standby Time: 24 Hours Standby Time 24 Hours <br /> vmm)thick UL Classified hollow core Precast Concrete Units'.When floor is constructed of hollow core precast concrete units,packing MODEL <br /> rn material(Item 3)and caulk fill material(Item 4)to be installed symmetrically on both sides of floor,flush with floor surface.Wall Total Standby Draw: 1.87 Amp-Hours Batteries Provided 2 PS-1270 Total Standby Draw: 1.87 Arrp-Hours Batteries Provided: 2 PS-1270 SYMBOL STY DESCRIPTION *ROUGH N <br /> ' assembly may also be constructed of any UL Classified Concrete Blocks'.Max diam of opening in solid lightweight or normal weight Battery Size: TOO A.H. Battery Size: 7.00 A.H. NUMBER <br /> Crete floor is 32 in.(813 mm).Max diam of opening in floor constructed of hollow-core precast concrete units is 7 in.(178 mm) Alarm Current 1.924 Amps Total Standby+Alarm 2.03 A.H.mp y (-) Alarm Current 2.286 Amps Total Standby+Alarm 2.06 A.H. (-) <br /> o See Concrete Blocks(CAZT)and Precast Concrete Units(CFTV)categories in the Fire Resistance Directory for names of manufacturers. F.B.O.<BY OTHERS> TAMPER SWITCH F.B.O. <br /> Alarm Time:=5 Minutes Correction Factor per NFPA 0.51 A.H. (-) Alarm TirTe:=S Min .H utes Correction Factor per NFPA 0.52 A . (-) <br /> 1A.Steel Sleeve-(Optional,Not Shown)-Nom 16 in.(406 mm)diam(or smaller)Schedule 10(or heavier)steel sleeve cast or grouted Total Alarm Draw: 0.16 Amp-Hours Spare Capacity. 4.46 A.H. (_) Total Alarm Draw: 0.19 Arty-Hours Spare Capacity: F.B.O.<BY OTHERS> WATER FLOW SWITCH F.B.O. <br /> into floor or wall assembly.Sleeve may extend a max of 2 in.(51 mm)above top of floor or beyond either surface of wall.As an alternate, <br /> nom 16 in.(406 mm)diam(orsmaller)min 0.028(0.71 mm)thick galvanized sheet steel sleeve castor grouted into floor or wall <br /> assembly flush with floor or wall surfaces. VOLTAGE DROP CALCULATION VOLTAGE DROP CALCULATION I] F.B.O.<BY OTHERS> JUNCTION BOX F.B.O. <br /> i 2.Through Penetrants-One metallic pipe,conduit or tubing to be installed either concentrically or eccentrically within the firestop Circuit Circuit Circuit Circuit Circuit Circuit Circuit Circuit <br /> BFP F.B.O.<BY 01 BACK FLOW PREVENTER F.B.O. <br /> system.Max annular space between pipe,conduit or tubing and edge ofthrough opening or sleeve is dependent on the parameters Device 1V1.1 1V'1.2 1V7.3 1VIA Total Device 1V2.1 1V2.2 1V2.3 1V2.4 Total QtV <br /> shown in Item 4.Min annular space between pipe or conduit and edge of through opening is 0 in.(point contact).Max annular space to Model#x=Red or White Current Curre Current Current Current Model#x=Retl or White Current Curren Current Current Current �nnti ------ END OF LINE RESISTOR --- <br /> be as shown in the table in Item 4.Pipe,conduit or tubing to be rigidly supported on both sides of floor or wall assembly.The following SLSCx-F 1 0.040 - 2 0.080 - - 2 SLHSCx-F 15cd D.044 13 10.572 13 1 0.572 12 1 Q528 10 0.440 48 <br /> types and sizes of metallic pipes,conduits or tubing may be used: SLHSCx-F(15cd) 0.044 9 0.396 5 0.220 11 0.484 10 0.440 35 Total Current 0.572 Amps 0.572 Amps 0 528 Anps 0 440 Amps <br /> A.Steel Pipe-Nam 30 in.(762 mm)diam(or smaller)Schedule 10(or heavier)steel pipe. - - (*)THE ABOVE REFERENCED'ROUGH IN'MOUNTING REQUIREMENTS INDICATED SHALL BE CONSIDERED AS A MINIMUM RECOMMENDATION ONLY.SPECIFIC HELD <br /> B.Iron Pipe-Nom 30 in.(762 mm)diam(or smaller)cast or ductile iron pipe. SLHSCx-F 30cd 0.065 -- 2 0.130 -- -- 2 Distance(Wire Length) 690 Feet 660 Feet 600 Feet 650 Feet CONDITIONS SHALL DICTATE ACTUAL ROUGH IN REQUIRED INSTALLATIONS.I.E.MULTIPLE CONDUIT RACEWAYS WITHIN A DEVICE BACKBOX,WIRE SIZE,WIRE TYPE,ETC. <br /> C.Conduit-Nom 6 in.(152 mm)diam(orsmaller)rigid steel conduit. Total Current 0.396 Amps 0.430 Amps 0.484 Amps 0.440 Amps Wire Size 12 AWG 12 AWG 12 AWG 12 AWG THE ADDITION OF EXTENSION RINGS OR LARGER BACKBOXES MAY BE REQUIRED TO BE INSTALLED TO ACCOMMODATE FOR ACTUAL FIELD CONDITIONS.ALTERNATE ROUGH <br /> - D.Conduit-Nom 4 in.(102 mm)diam(orsmaller)steel electrical metallic tubing. Distance(Wire Length) 520 Feet 560 Feet 770 Feet 540 Feet Resistance(per 1000 ft) 1.98 Ohms 1.98 Ohms 1.98 Ohms 1.98 Ohms IN EQUIPMENT WHICH MEETS SIEMENS INSTALLATION STANDARDS AND IS OF A LIKE NATURE MAY BE UTILIZED.ALL ROUGH IN INSTALLATION SHALL PROPERLY COMPLY <br /> E.Copper Tubing-Nom 6 in.(152 mm)than(or smaller)Type L(or heavier)copper tube. Wire Size 12 AWG 12 AWG 12 AWG 12 AWG Starting Circuit Voltage 24.00 Volts 24.00 Volts 24.00 Volts 24.00 Volts WITH ALL APPLICABLE CODES/STANDARDS/REGULATIONS.TO MINIMIZE ANY COST IMPACTS ALL ISSUES AND DISCREPANCIES MUST IMMEDIATELY BE BROUGHT TO THE <br /> F.Copper Pipe-Nom 6 in.(152 mm)diam(or smaller)Regular(or heavier)copper pipe. Resistance(per 1000 ft) 1.98 Ohms 1.98 Ohms 1.98 Ohms 1.98 Ohms Voltage Drop 1.56 Volts 1.49 Volts 1.25 Volts 1.13 Volts ATTENTION OF SIEMENS PRIOR TO ANY ROUGH-IN/INSTALLATION. AGENCY REFERENCE: <br /> 3.Packing Material-Polyethylene backer rod or nom 1 in.(25 mm)thickness of tightly-packed mineral wool bat,or glass fiber Starting Circuit Voltage 24.ED V V. 24.00 Volts 24.00 Volts 24.00 Volts Voltage @ End of Circuit 22.44 Volts 22.51 Volts 22.75 Volts 22.87 Volts <br /> insulation firmly packed into opening as a permanent form.Packing material to be recessed from top surface of floor or from both voltage Drop 0.82 Volts 0.95 Volls 1.48 Vats 0.94 Volts Building BROADWAY EVERETT SELF-STORAGE <br /> surfaces of wall as required to accommodate the required thickness of caulk fill material(Item 4). Voltage @ End of Circuit 23.18 Volts 1 23.05 Volts1 22.52 Volts 1 23.06 Volts Calculation Method: VOLTAGE DROP=2.TOTAL CURRENT.DISTANCE x RESISTANCE Panel#.Remote Power Supply 1 V3 <br /> aI 3A.Forming Material--As an alternate to the packing material in Item 3,nom 4 in.(102 mm)wide strips of min 1/2 in(13 mm)thick 700° Panel Location ELECTRICAL ROOM-103 <br /> Calculation Method: VOLTAGE DROP-2 x TOTAL CURRENTx DISTANCE x RESISTANCE VOLTAGE @ END OF CIRCUIT STARTING CIRCUIT VOLTAGE-VOLTAGE DROP <br /> compressible mat to be stacked to a thickness greater than the width of the annular space and compression-fitted,edge-first,to fill the BATTERY SIZING CALCULATION <br /> 8/5/2023 <br /> annular space to d min 4 in.(102 mm)depth.AS an option,the strips Of min 1/2 in.IF thick compressible mat may be folded in half, 100a OPERATING VOLTAGE RANGE FOR 24V NOTIFICATION APPLIANCES TO BE 16V-33V <br /> p p p p pressi y Device city Standby Total Standby Alarm Total Alarm <br /> lengthwise,and stacked to a thickness greater than the width of the annular space and compression-fitted,edge-first,to fill the annular VOLTAGE @ END of CIRCUIT-STARTING alRculrvoLTAGE-voLTAGE DROP <br /> space to a min 2 in.(51 mm)depth.Top of forming material to be recessed from top surface of floor or from both surfaces of wall as OPERATING VOLTAGE RANGE FOR 24V NOTIFICATION APPLIANCES TO BE 161 Main Board <br /> necessary to accommodate the required thickness of caulk fill material. PAD5-6A 1 0 078 0.078 0.174 0.174 <br /> 3M COMPANY-Fire Barrier Packing Material Circuits <br /> 1V3.1 7 - - - 0.308 <br /> 4.Fill,Void or Cavity Material'-Caulk Sealant-Applied to fill the annular space flush with top surface of floor.In wall assemblies, 1V3.2 10 - - - 0.440 00 OB/08/23 ISSUED FOR PERMIT APK <br /> required caulk thickness to be installed symmetrically on both sides of wall,flush with wall surface.At point contact location between WIRING GUIDELINES WIRING REQUIREMENTS REV DATE REMARKS INIL <br /> penetrant and sleeve or between penetrant and concrete,a min 1/4 in.(6 mm)diam bead of caulk shall be applied at top surface of floor SPARE 0 - - - SLOW N0. <br /> and at both surfaces of wall.The hourly F Ratings and the min required caulk thicknesses are dependent upon a number of parameters, <br /> as shown in the following table: Standby Current Alarm Current DRAWN: APK <br /> PLENUM CABLE VS. NON-PLENUM THE DRAIN SHIELD IS A VERY IMPORTANT PART OF THE SYSTEM INSTALLATION. Sandbycurrent 0.078 Amps 0.078 oszz CHECKED: GN <br /> Min Floor or wall Nom Pipe Tube or Max Annular Min Caulk F Rating Standby Time 24 Hour. <br /> Thknsln.(mm)Conduit Do,in.(mm Space in.(mm)rhm.ln.(mm Hr SHIELDED WOULD NOT SPECIFY SHIELDED CABLE IF IT WAS NOT NECESSARY. Total Standby Draw: 1.87 Arrp-Hours Batteries Provided: z Ps-127o SHEET DESCRIPTION: <br /> n 2-1/2(64) 1/2-12(13-305) 1-3/6(35) 1/2(13) z THE NEC RECOGNIZES 3 TYPES OF POWER LIMITED FIRE ALARM CABLING: SHIELDS SHOULD BE KEPT CONTINUOUS THROUGHOUT THE CIRCUIT AND KEPT <br /> 2-1/2(64) 1/2-12(13-305) 3-1/4(83) 1(25) z FREE FROM ANY REFERENCE TO EARTH GROUND. Battery Si- 7.00A.H. FIRE ALARM SYSTEM <br /> 4-1/2(114) 1/2-6(13-152) 1-3/8(35) 1/4(6)(a) 2 Alarm Current: 0.922 Amps Total Standby+Alarm 1.95 A.H. (-) SEQUENCE EQUIPMENT LIST S <br /> FPL - THIS IS A GENERAL USE POWER LIMITED FIRE ALARM CABLE. IT CANNOT BE r <br /> 0 4-1/2(114) 1/2-12(13-305) 1-1/4(32) 1/2(13) 3 Alarm Time�5 Minutes correction Factor per NFPA OA9 AM (-) VOLTAGE DROP CALCULATIONS <br /> 4-1/2(114) 1/2-20(13-508) 2(51) 1(25) 3 USED N A PLENUM SPACE OR FOR RISERS (CABLING BETWEEN FLOORS), CABLE • SHIELDED CABLE CAN BE FPL, FPLR, OR FPLP. NETWORK COMMUNICATIONS <br /> 4-1/2(114) 1/2-20(13-508) 2(51) 1(25) 3 MUST BE IN CONDUIT. BETWEEN FIRE ALARM CONTROL PANELS AND REMOTE ANNUNCIATORS REQUIRE Total Alarm Draw: 0.08A p-Hours Spare Capacity: <br /> 4-1/z(114) 1/2-12(13-305) 3-1/4(83) 1(25) 3 SHIELDED CABLE. <br /> 4-1/2(114) 22-30(558-762) z(51) z(51) 3 FPLR - THIS S A POWER LIMITED RISER RATED CABLE THAT CAN BE USED FOR <br /> m 5-1/2(140) 1/2-6(13-152) 1-3/e(3s) 1(zs)(b) 4 GENERAL PURPOSES OR BETWEEN FLOORS. IT CANNOT BE USED IN A PLENUM • INTELLIGENT ADDRESSABLE INITIATING DEVICES REQUIRE NON-SHIELDED CABLE. voLrnGEDROPCALcuLtAroN JOB NUMBER: <br /> Circuit Circuit Circuit Circuit 440P-360662 <br /> SPACE, CABLE MUST BE IN CONDUIT. Device 1V3.1 1V3.2 SPARE SPARE Total <br /> (a)Min2in(51 mm)thickness of mineral wool batt insulation orforming material(hem 3A)required in annular space. <br /> NOTIFICATION APPLIANCES (I.E. - HORN/STROBES, HORNS, ETC.) REQUIRE Model#x=Red or White Current Curre Current Current Current <br /> FPLP - THIS IS A POWER LIMITED CABLE THAT CAN BE USED IN A PLENUM, RISER, NON-SHIELDED CABLE. SLHscx-F 15cd 0.0" 7 1 0.308 10 0440 17 PROJECT NAME ADDRESS: <br /> i (b)Mm 1 in.(25 mm)thickness of mineral wool batt insulation required in annular space on both sides of floor or wall assembly.Min 1 OR FOR GENERAL PURPOSE. Total Current OF308 Amps 0440 Amps 0.000 Amps 0.000 Amps <br /> in.(25 mm)thickness of caulk to be installed flush with each surface of floor or wall assembly. Distance(Wire Length) 500 Feet 500 Feet Feet Feet SECURE SELF STORAGE-EVERETT EXPANSION <br /> UNDERGROUND CABLE, WHETHER OR NOT INSTALLED IN CONDUIT, SHALL BE Wire Size 12 AWG 12 AWG Feet <br /> 12AVIG BROADWAY EVERETT SELF STORAGE <br /> y 3M COMPANY-CP 25WB+or FB-3000 VVT. A PLENUM IS ANY AREA USED TO CONDUCT ENVIRONMENTAL AIR. PLENUM SPACES • LISTED AS UNDERGROUND BURIAL TYPE. Resistance(per 1000 ft) 1.98ohne 1.98ohrrs 1.98 Oh- 1.98 Oh- 8407BROADWAY <br /> CAN BE DUCTWORK, THE SPACE ABOVE A DROP CEILING, OR BELOW A RAISED <br /> (Note-W Rating applies only when FB-3000 WT is used.) Starting Circuit Voltage 24. Volts 24.00 volts 24.00 Volts 24.00 Volts EVERETT,WA 98208 <br /> FLOOR. BECAUSE THESE SPACES ARE BEING USED FOR THE AIR HANDLING SYSTEM. WIRING IS TO BE INSTALLED POINT TO POINT WITH NO SPLICING. voltage Drop 61 oslvolt 0 87volt6 o.00Va. o.00votts <br /> 'Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification(such THERE ARE STRICT RULES THAT MUST BE FOLLOWED TO REDUCE THE RISK OF Voltage@End of Circuit 23.39 Volts 1 23.13 Volts 24.00 Volts 1 24.00 Volts <br /> as Canada),respectively. INTRODUCING TOXIC FUMES IN THE EVENT OF A FIRE. SINCE FIRE ALARM CABLING IS DRAWING <br /> OFTEN INSTALLED EXPOSED, WITHOUT CONDUIT, ABOVE DROP CEILINGS THE CABLING Calculation Method'_ VOLTAGE DROP=2x TOTAL CURRENT.DISTANCEx RESISTANCE NUMBER: ��O■O� <br /> MUST BE RATED FOR USE IN A PLENUM SPACE. ow VOLTAGE VOLTAGE @ ENO OF CIRCUIT=STARTING CIRCUIT VOLTAGE-VOLTAGE DROP i <br /> OPERATING VOLTAGE RANGE FOR 24V NOTIFICATION APPLIANCES TO BE 16V-33V <br /> SHEET SIZE:ARCH El-30AI <br />