Laserfiche WebLink
SIEMENS <br /> • • l ' 1 • <br /> ProductOverview <br /> Models FT2014-U2/R2 and FT2015-U2/112: The Remote Display Terminals (Models FT2014-U2 I R2 and FT2015-U2 I <br /> R2)are remote light-emitting diode(LED)I liquid-crystal display(LCD) units <br /> ❑ 2"-x-4-1/4"backlit LCD screen that show the existing status of a Desigo 252 1 504-point system. <br /> ❑ Event and audible status LEDs A LED will illuminate for any given Alarm, Gas Alarm, Supervisory and <br /> ❑ Supports'Class B'(Style 4)or'Class A' Trouble Desigo-system event. A 2"-x- 4-3/4" LCD screen will give details of <br /> (Style 6)wiring the event in alphanumeric form. The display screen can be scrolled to <br /> reveal additional events. Optional remote-system-control capabilities are <br /> ❑ Built-in transient protection also available. <br /> ❑ Mounts in its own enclosure The Remote Display Terminals (as well as Model FCA2016-U1) are FM <br /> ❑ Optional system control (#3010); FDNY(#6104)and CSFM (#7165-0067:0259)Approved. <br /> ❑ Downloadable firmware Specifications <br /> Built-in flash electrically erasable The remote display terminals have separate LEDs for Alarm, Gas Alarm, <br /> programmable read-only memory Supervisory, and Trouble events on a Desigo FACP. Each LED will flash <br /> (EEPROM) when 'unacknowledged' events are present. The LED will change to <br /> ❑ Scroll buttons to view additional events steady, upon acknowledgment of the event. <br /> ❑ Local sounder Additionally, the remote display terminals have an LED to indicate system <br /> ❑ UL 864 9th Edition Listed, ULC Listed power; a separate ground-fault LED, and four (4) additional user- <br /> ❑ FM,CSFM&NYC Fire Dept.Approved programmable LEDs. <br /> There are also two(2) LEDs that indicate the state of audible circuits on the <br /> Model FCA2016-U1: system: <br /> ❑ RS-485 module provides communication to ' One(1) LED to indicate that the circuits are'active' <br /> Remote Display Terminals(Models FT2014, ' One(1) LED to indicate the Circuits have been'silenced' <br /> FT2015) When the Desigo FACP is in 'normal' state <br /> ❑ Dual,standardized RS-485 interface (with no events present), the screen will <br /> annunciate the date and time-of-day. <br /> ❑ Supports'Class B'(Style 4)and'Class A' <br /> (Style 6)wiring configurations When an event has been triggered to the <br /> Desigo panel, the LCD display will show the <br /> ❑ Electrical isolation between the RS-485 following: <br /> interface and Desigo panel y <br /> ❑ Ground-fault monitoring ' Event type and zone <br /> ■ Custom message for that zone <br /> ❑ Up to eight(8)devices on the RS-485 Style 6 ■ Usage of the zone <br /> loop Universal Fire Protocol(UFP)limitation ■ 'Unacknowledged'or'Acknowledged'event Remote Display Terminal <br /> ❑ UL 864 9th Edition Listed, ULC Listed In addition to the aforementioned features, <br /> ❑ FM,CSFM&NYC Fire Dept.Approved <br /> the display will show the total number of all <br /> types of events present on the system. The <br /> display has a backlight feature that operates <br /> upon receiving any event status or when any <br /> operator buttons are pressed. <br /> U` UI C FM 0` <br /> APPROVE. - RS-485 Interface <br /> Siemens Datasheet 6812 <br /> Smart Infrastructure— Building Products <br /> usa.siemens.com/fire <br />