Laserfiche WebLink
Specifications <br /> The Model FT2O14-series display terminal has a local sounder that operates when any new events are displayed on the <br /> system. Pressing the local sounder silence button or any operator buttons will silence the local sounder when an event is <br /> present. <br /> Each remote display terminal has a navigation button that is used for displaying next-event or previous-event information <br /> in the sequence,and has a local sounder silence button. <br /> Model FT2014-series has one (1) button used to silence the local sounder. The Model FT2015-series has three (3) control <br /> buttons for'acknowledging' events, silencing audible circuits and resetting the system. Additionally, there are three (3) <br /> user-programmable buttons available. The Mode[ FT2O15-series has an integral key switch that enables the control <br /> buttons to operate. <br /> The remote display terminals are remotely connected to the Desigo FACP, via the RS-485 interface. The Mode[ 252-point <br /> and 504-point Desigo panels require the Mode[ FCA2O16-U1 RS-485 module to provide communication to the remote <br /> display terminals. Model FCA2016-U1 supports Style 4 or Style 6 wiring. <br /> Up to eight(8) modules can be supported on a given RS-485 communications bus. <br /> 24-Volt power is required to run the remote display terminals, and can be provided from a Desigo FACP or other UL Listed <br /> 24VDC power source. <br /> The remote display terminals have screw terminals capable of supporting 12 to 22 American Wire Gauge(AWG). <br /> The remote display terminals can be mounted to a (2) two-gang electrical box or a (4) four-inch square electrical box. No <br /> flush-trim kit is required. Each unit is approximately 12-1/4"(31.2cm.)wide; 9"(22.9cm.) high;and 2-1/2"(6.4cm.) deep. <br /> Each RS-485 interface is approximately 1.97" (5cm.) wide; 2.76" (7cm.) high; and 0.6" (1.5cm.) deep. The weight of <br /> Mode[ FCA2O16-Ul is 0.044 Lbs. (2Og). <br /> • - • • . - <br /> Products are UL 864 9th Edition listed for indoor dry locations within a temperature range of 120+/YF (2°C)to 32+1 YF <br /> (0+12°C)Temperature and Humidity Range and a relative humidity of 93+/2%at a temperature of 90+13°F (32+/2°C). <br /> Voltage 3.3VDC Model Part <br /> or Type Number Description <br /> Normal Approx.75 mA <br /> Operating (Standby mode) <br /> Current FT2014-U2 S54400-F67-A1 Remote Display Terminal <br /> RS-485 Alarm Approx.136 mA <br /> Interface FT2014-R2 S54400-1375-A1 Remote Display <br /> Connection Bus structure F Terminal,Red <br /> Communication mode Half-duplex FT2015-U2 S54400-F68-A1 �[Remote Display Terminal <br /> [with control] <br /> Number of Participants Eight(8),max. FT2015-R2 S54400-B15- 1 <br /> 1 Remote Display Terminal <br /> 3940 ft.(1200 meters) [with control],Red <br /> Wire Length (unshielded/twisted-pair FCA2016-U1 S54400-A39-A1 RS485 Interface <br /> wiring)for both Class A& <br /> Class B <br /> RS-485 Interface <br /> Design 4_pole screw terminal <br /> - ----------------------------- Product Datasheet# <br /> Connections Admissible Cross-Section 12 to 22 American Wire <br /> Cable Gauge(AWG) Remote Peripheral Module 6811 <br /> To the operating unit Fplug-in-type connection <br /> 252-point Desigo Fire Safety System <br /> FT2014-series <br /> Power 24VDC @ 55mA 504-point Desigo Fire Safety System <br /> Requirements <br /> FT2015-series Intelligent Voice 6821 <br /> Communication system �F <br /> Siemens <br /> Smart Infrastructure— Building Products —2— usa.siemens.com/fire <br />