PANEL AZIMUTH PITCH TSRF AREA FRAMING SIZE CEILING JOIST/ MAXIMUM MAXIMUM TOTAL PV ARRAY AREA(W) 167.99 <br /> ROOF MATERIAL SHEATHING TYPE FRAMING TYPE PURLINS SIZE RACKING TYPE ATTACHMENT TYPE ATTACHMENT CANTILEVER TOTAL ROOF AREA(W) 1330 <br /> COUNT (DEG) (DEG) (%) (ff') AND SPACING AND SPACING SPACING(S) (C) DISTRIBUTED LOAD(psf) 2.2 <br /> MPl 8 176 27 74 636 Standing Seam Metal SKIP Rafter 2x4 @ 24 in OC 2x4 @ 19.2 in OC UNIRAC SOLARMOUNT LT S-5-S CLAMP 32"L/32"P 10"L/10"P ROOF COVERAGE(%) 12.63 <br /> MP2 0 TOTAL PV ARRAY WEIGHT(Ibs) 370.4 <br /> MP3 0 TOTAL PV ATTACHMENTS 32 BLUE RAVEN <br /> MP4 0 POINT LOAD(Ibs/aft.) 11.6 SOLAR <br /> MPS 0 <br /> MP6 0 1403 N 630 E <br /> MP7 0 n Orem, Utah 84097 <br /> MP8 0 !-1 (800) 377-4480 <br /> MP9 0 BlueRavenSolar.com <br /> MP10 0 <br /> ATTACHMENT TYPE: <br /> PV MODULES SHALL NOT EXTEND S-5! Clamp <br /> ABOVE ROOF RIDGE LINE <br /> 0 <br /> PV MODULE MAX CANTILEVER Q <br /> PER TABLE ABOVE (/iCl ::D _ <br /> U <br /> UNIRAC SM UNIRAC SM co <br /> PRO SERIES PV MODULE UNIRAC SM LT RAIL PRO SERIES CD co N <br /> END CLAMP MID CLAMP N Q Q <br /> 00 N <br /> >` o, 0 N <br /> Q o, <br /> N <br /> i � } <br /> � o 0 <br /> ROOF MATERIAL NOT } <br /> SHOWN FOR CLARITY EXISTING FRAMING w <br /> } •� U U <br /> LIJ 3 ° <br /> L <br /> T T > } U <br /> � Q ° <br /> ATTACHMENT SPACING U <br /> PER TABLE ABOVE co N LU N <br /> FRAMING SPACING 0 E <br /> *THIS DETAIL IS NOT MEANT TO BE PER TABLE ABOVE <br /> FRAMING DETAIL EXTERIOR WALL AN EXACT REPRESENTATION OF ATTACHMENT DETAIL ``' } o <br /> SCALE: 1/2"= 1'-0" FRAMING OR PV MODULE LAYOUT SCALE: 1-1/2"= 1'-0" a cn <br /> RIDGE ° <br /> NOTES U <br /> r <br /> Use S-5-S clamps based on the shape of these seams.Seams are spaced l6in apart,so the attachments spacing will be = <br /> LANDSCAPE PORTRAIT 32in. p p p p p g Q <br /> ROJECTID: <br /> STRUCTURAL UPGRADES REQUIRED.Final Design Cover Sheet Scope of Work:Structural Upgrade Required to 11 of the 9 7 72 9 5 <br /> 1� existing rafters to handle the additional weight of the proposed PV array. <br /> I I I I I I <br /> V DC SYSTEM SIZE: <br /> 3.360 kW DC <br /> Sister upgrade is required for Sealed For VAC SYSTEM SIZE: <br /> 17 (MP1) on all rafters that directly Existin Roof& 2.600 kW AC <br /> g <br /> support solar PV. Stitch new VISIONS: <br /> Attachment Only <br /> 22"MIN 2x6 DF#2 (min) to existing <br /> A 8/b/2024 <br /> 4"MAXI 28"TYP <br /> 3 member. See detail for B ---- <br /> I I I I I I <br /> 2 MIT- T� additional information. ---- <br /> A• <br /> 22"MAX I I 12"TYP C4 I ) - <br /> I I I I I I I I I 1 � LL <br /> • 34"MIN " QF WAS RAWN BY: <br /> 40 TYP <br /> 46"MAX 1 Q � `�, <br /> 23"MIN I Grace Hymas <br /> 43"MAX 33"TYP I I • LOT DATE: <br /> I..MIN 1 11"MIN 14"TYP - AUgust 6, 2024 <br /> 11''MAX 6 TYP 17" IMAX RAWING TITLE: <br /> 46056 <br /> Structural <br /> FOLLOW ATTACHMENT SPACING IN TABLE ABOVE 8n/24 �SSI�NALEN�'l RAWING NUMBER: <br /> EAVE *ATTACHMENT PATTERN SHOULD BE <br /> ATTACHMENT PATTERN STAGGERED UNLESS OTHERWISE 1/4"= 1'-0" NOTED IN ENGINEERING LETTER PV4 <br />