My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2731 WETMORE AVE FUNKO 2024-11-12
>
Address Records
>
WETMORE AVE
>
2731
>
FUNKO
>
2731 WETMORE AVE FUNKO 2024-11-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2024 7:39:38 AM
Creation date
10/30/2024 11:19:18 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2731
Tenant Name
FUNKO
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WETMORE <br /> Permit#: FA2401-008 ?BULDNIS Site Address: 2731 Wetmore Ave <br /> Applicant: Fire Protection Inc <br /> Application Date:01/16/2024 FIRE PROTECTION INC. <br /> Description: Installation of a UL Listed Wireless 17410 Ash Way,Ste 8 <br /> Fire Alarm Communicator Lynnwood,WA 98037 <br /> Review Date: 01/17/2024 425-290-9600 <br /> FPISEATTLE.COM <br /> WRELFISS COMMUMCATOR NSTALLATON EverettStatus:`Depptt.eermitt Review 1 <br /> Reviewed By:KBrown <br /> 01/17/2024 8:01:58 NFPA <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET INDEX AM <br /> 000805173 <br /> SHEET # SHEET DESCRIPTION <br /> FA 0.0 FIRE ALARM AES INSTALLATION ROY L CATS <br /> QAlQpOTECTjOy <br /> W NT <br /> PROJECT DETAILS <br /> ; NFPA ^' <br /> Oo <br /> 1. THE EXISTING FIVE—STORY BUILDING IS SPRINKLED AND HAS AN EXISTING CONVENTIONAL FIRE ALARM CFPS <br /> CONTROL PANEL (SILENT KNIGHT 5208) LOCATED IN THE FACP ROOM ON THE 2ND FLOOR. <br /> #1473 <br /> O O O O O @ 2. A NEW UL LISTED WIRELESS CELLULAR COMMUNICATOR (TG-7FS) IS BEING INSTALLED AT THE FACP. ALL <br /> SIGNALS WILL BE TRANSMITTED BY ZONES TO THE ILL LISTED SUPERVISING STATION. <br /> 0 3. THE NEW CELLULAR COMMUNICATOR SHALL TRANSMIT THE EXISTING FACP ZONES. <br /> VICINITYMAP aw auce O O O 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. <br /> rx.a--x m _ <br /> Ox xnlxmw0 F Q m O m <br /> F IL <br /> VF W <br /> Ox❑ Z V W <br /> W=N N <br /> PROJECT CONTACT INFO <br /> O O WyS N <br /> R 2°yVy � <br /> ¢E# <br /> OWNER/TENANT FIRE ALARM CONTRACTOR r�j a r <br /> B GT WETMORE LLC FIRE PROTECTION INC Y¢W n¢ <br /> BATTERY 0 0 1421 34TH AVE, SUITE 300 17410 ASH WAY, Ste 8 =°y w LL <br /> Tulalip Indian Reser'sville,,. <br /> tion SEATTLE, WA 98122 LYNNWOOD, WA 98037 yO015 n0 3 <br /> xox, <br /> CONTACT MICHAEL DENTON CONTACT DAVID MOWPHONE : 425359.9339 PHONE 425.290.9600 <br /> TELGUARD TG-7FS IVIa ` '°"` '°"` '°" `"' micheeld®funko.com davidCaTfpiseattle.coma REVISION RECORD <br /> CODE INFO DATE DESCRIPTION <br /> 2731 Wetmore Ave, AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> Everett,WA 98201 FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> BUILDING USE AND OCCUPANCY : (B) — FULLY SPRINKLED <br /> IVlukilte0 STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> Duget CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> iOURd MOn REMOTE SUPERVISING STATION : SECURITAS INC. <br /> EXISTING CONVENTIONAL FACP(SILENT KNIGHT 5208 FIRE PANEL) PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC <br /> Edmonds PARCEL NUMBERS 00439162601300 <br /> ..` r <br /> Shoreline Bothell INSTALLATION NOTES <br /> TYPICAL WIRING AND INSTALLATION DETAILS 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS—BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 01/10/2024 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE—TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safe Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> INSPECTION. <br /> Central Supervising Station °g <br /> Control Unit Annunciation ,� 6. THE CELLULAR COMMUNICATOR REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE <br /> °c �° FACP SHALL DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING <br /> °c DEDICATED POWER TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT tO <br /> °c yo9 0, m` me m SERVES THE FIRE ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED <br /> °j �?•� � BREAKER LOCKOUT (NFPA72, SECTION 10.5.5.2). <br /> EVERETT AVE y ei9 cw ® N <br /> �c W r <br /> aLg°` 07 > G <br /> c' $~0, A_,0cc° Q 00 <br /> N <br /> DEVICE INSTALLATION REQUIREMENTS Z W <br /> y p) <br /> A. <br /> ° ` �'�� ° FIRE ALARM DEVICE INSTALLATION REQUIREMENTS <br /> g� Fy ycm m W H <br /> W j ��4 OF� °r y 3 yS NOT PERMITTED W <br /> ' ¢ Q y U = ° DIFFUSER "ERE a' LU <br /> 0i 4. c SUPPORT <br /> W ¢ IY 0 e 0 ° .0 v�•C O BRACKET ACT r <br /> ¢ o J as oa as ai'��`a3' a -eox cRlo101 <br /> O m � <br /> m w : v m E F 6 8 m,m FA DEVICE CEILING IN11 SMOK1.11E <br /> F_d BE N W <br /> U w�.?�w� c°' c c c y DETECTOR WO O V O `@ `ry `ry try 4 �, MINIMUM ,x x ! { / { AWAY FROM NOT PERMITTEFACP on SYSTEMINPUTS A B C D E F G H Hvnc DIFFusERs HERE2ND FLOOR 1 Manual Fire Alarm PullStation ♦ ♦ ♦ 1 <br /> OUTDOOR 2 Smoke Detectors ♦ ♦ ♦ 2 <br /> BELL 43 Heat Detectors ♦ ♦ ♦♦ 3 SHEET TITLE <br /> 4 Wet Waterflow A.HEIGHT ez"YYI <br /> ♦ ♦ ♦♦♦ 4 MIN HEIGHT 82"A.F.F ® 160 3 <br /> a 5 Sprinkler Tamper/PIV ♦ ♦ 5 <br /> CALIFORNIA ST (0 6 Duct Detectors ♦ ♦ 6 ®� <br /> FIRE ALARM <br /> 7 Fire Alarm AC Power Failure ♦ ♦ 7 p 4 COMMUNICATOR <br /> INSTALLATION DETAIL <br /> m8 Fire Alarm System Low Battery ♦ ♦ 6 fifi A.F.F fio'A.F.F puLL <br /> 9 Open Circuit ♦ ♦ 9 <br /> N10 Ground Fault ♦ ♦ 10 SHEET NUMBER <br /> A B C D E F G H I <br /> K <br /> Not to Scale FA <br /> O.O <br />
The URL can be used to link to this page
Your browser does not support the video tag.