Laserfiche WebLink
WETMORE <br /> BU LDN � FIRE PROTECTION INC. <br /> 17410 Ash Way,Ste 8 <br /> Lynnwood,WA 98037 <br /> 425-290-9600 <br /> FPISEATTLE.COM <br /> WRELESS COMMUMCATOR NSTALLATON <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET INDEX NFPA <br /> 000805173 <br /> SHEET # SHEET DESCRIPTION <br /> FA 0.0 FIRE ALARM AES INSTALLATION ROY L CATS <br /> QAlQpOTECTjOy <br /> NT W <br /> PROJECT DETAILS !9 <br /> Yy NFPA ^' <br /> Oo <br /> 1. THE EXISTING FIVE-STORY BUILDING IS SPRINKLED AND HAS AN EXISTING CONVENTIONAL FIRE ALARM CFPS <br /> CONTROL PANEL (SILENT KNIGHT 5208) LOCATED IN THE FACP ROOM ON THE 2ND FLOOR. <br /> #1473 <br /> O O O O O 2. A NEW UL LISTED WIRELESS CELLULAR COMMUNICATOR (TG-7FS) IS BEING INSTALLED AT THE FACP. ALL <br /> SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. <br /> 0 3. THE NEW CELLULAR COMMUNICATOR SHALL TRANSMIT THE EXISTING FACP ZONES. <br /> O VICINITY MAP awvauce O O 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. <br /> �xsxexlx m _ <br /> x Ox xnlxmw0 F O m O m Co <br /> W Z ° <br /> F IL <br /> VF W <br /> Ox❑ Z V W <br /> W=N N <br /> PROJECT CONTACT INFO <br /> O O WyS N <br /> R 2°yVy P. <br /> ¢E# <br /> OWNER/TENANT FIRE ALARM CONTRACTOR R GT WETMORE LLC FIRE PROTECTION INC Y¢W n r <br /> ¢ <br /> BATTERY o o 1421 34TH AVE, SUITE 300 17410 ASH WAY, Ste 8 L <br /> Tulalip Indian Reservation SEATTLE, WA 98122 LYNNWOOD, WA 98037 y OO u F 0 3 <br /> xox, <br /> Lry CONTACT MICHAEL DENTON CONTACT DAVID MOW m w G <br /> PHONE : 425.359.9339 PHONE : 425.290.9600 <br /> TELGUARD TG-7FS 3 W C=a ° <br /> ` IVIarySVll�e ` '°"` '°"` '°" `"' michaeld®funko.com david CaTfpiseattle.com w w+'7 rc ¢ <br /> orcwa�a o <br /> �� REVISION RECORD <br /> CODE INFO DATE DESCRIPTION <br /> 2731 Wetmore Ave, AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> Everett,WA 98201 FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> BUILDING USE AND OCCUPANCY : (B) - FULLY SPRINKLED <br /> MUkilteo STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> Duget CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> 'ound MOn REMOTE SUPERVISING STATION : SECURITAS INC. <br /> EXISTING CONVENTIONAL FACP(SILENT KNIGHT 5208 FIRE PANEL) PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC <br /> Edmonds PARCEL NUMBERS 00439162601300 <br /> ..` r <br /> Shoreline Bothell INSTALLATION NOTES <br /> TYPICAL WIRING AND INSTALLATION DETAILS 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 01/10/2024 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safe Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> INSPECTION. <br /> Central Supervising Station °g <br /> Control Unit Annunciation ,� 6. THE CELLULAR COMMUNICATOR REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE <br /> °c �o FACP SHALL DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING <br /> °c DEDICATED POWER TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT tO <br /> °c yo9 06� m` me m SERVES THE FIRE ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED <br /> °j <br /> EVERETT AVE �?•� � BREAKER LOCKOUT (NFPA72, SECTION 10.5.5.2).y N <br /> ei9 cw ® �c W r <br /> > G <br /> ~o Z-,occ° — N <br /> y��Q° Z m �c DEVICE INSTALLATION REQUIREMENTS W 0) <br /> A. <br /> FIRE ALARM DEVICE INSTALLATION REQUIREMENTS <br /> g� Fy ycmw0 m W H <br /> W j ��Ja OF A` O�y 3 yS NOT PERMITTED LU <br /> ' ¢ Q y U C Z ° LU <br /> DIFFUSER <br /> "ERE a <br /> 0i O) l SUPPORT <br /> W ¢ d' 0 e 0 ° .0 v�•C O BRACKET ACT r <br /> ¢ o B.1 as oa as ai'��`a3' a -eox c 1 O M B <br /> m w : v m E F 6 8 m,m FA DEVICE CEILING IN11 SMOKE F_ N W <br /> 00 U w�.?�w� c°' c c c y DETECTOR a" W <br /> FF_� _]FACPon <br /> I V V V `@ `ry `ry try 4 �, MINIMUM 3' <br /> xr Q xr !� {� /� {� Q Q AWAY FROM NOT PERMITTED 2" <br /> SYSTEM INPUTS A B C D E F G H H Hvnc DIFFusERs HERE SMOKE <br /> 2ND FLOOR 1 Manual Fire Alarm Pull-Station ♦ ♦ ♦ 1 <br /> OUTDOOR Ix 2 Smoke Detectors ♦ ♦ ♦ 2 <br /> BELL 4 3 Heat Detectors ♦ ♦ ♦♦ 3 J SHEET TITLE <br /> 4 Wet Waterflow 4 A.HEIGHT ez"aF.F <br /> ♦ ♦ ♦♦♦ MIN HEIGHT 82"AYY ® 60 3 <br /> a 5 Sprinkler Tamper/PIV ♦ ♦ 5 <br /> CALIFORNIA ST (06 Duct Detectors ♦ ♦ 6 ®� <br /> FIRE ALARM <br /> 7 Fire Alarm AC Power Failure ♦ ♦ 7 p 4 COMMUNICATOR <br /> INSTALLATION DETAIL <br /> m8 Fire Alarm System Low Battery ♦ ♦ a fifi•A.F.F fio'A.F.F puLL <br /> 9 Open Circuit ♦ ♦ 9 <br /> N10 Ground Fault ♦ ♦ 10 SHEET NUMBER <br /> A B C D E F G H I <br /> K <br /> Not to Scale FA <br /> O.O <br />