Laserfiche WebLink
Permit#: FA21.ilv2 �r <br /> /� Site Address: 11221 Silver Lake Rd <br /> CTY 0FEVERETT — FRE <br /> ST /\ 07Applicant: Fire Protection Inc <br /> Application Date:02/19/2024 FIRE PROTECTION INC. <br /> Description: Install a Wireless Fire Alarm IRE P Ash Way,Ste 8 <br /> Communicator Lynnwood,WA 98037 <br /> Review Date: 02/21/2024 425-290-9600 <br /> FPISEATTLE.COM <br /> AES RADO NSTALLATONApproved <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 02/21/2024 12:43:34 <br /> PM <br /> TYPICAL INSTALLATION DETAIL SHEET INDEX NFPA® <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> FA 0.0 FIRE ALARM : AES INSTALLATION ROY L CATS <br /> AlQp0TECTjO <br /> PROJECT DETAILSIn <br /> Q ? <br /> W N9 <br /> n <br /> 1. THE EXISTING TWO—STORY BUILDING IS FULLY—SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ALARM �'y NFPW �^ <br /> CONTROL PANEL(ADEMCO VISTA 128FB FIRE PANEL) LOCATED IN THE WEIGHT ROOM ON THE SECOND FLOOR. <br /> CFPS <br /> 2. A NEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88—ULP) IS BEING INSTALLED, SIGNALS WILL BE <br /> 12 <br /> TRANSMITTED BY ZONE TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah BATTERY WILL BE #1473 <br /> "°�aer ( c�uRjs'sj INSTALLED IN THE NEW AES RADIO. <br /> o°5 °Ra�`nrev°/n°iaso°ry rvlc r <br /> 3. THE NEW AES RADIO WILL USE THE EXISTING FACPs DIALER TO SEND CONTACT ID AND ONBOARD RELAYS TO <br /> I J",�'F virvTaasei"D �*"s"$"'�"� TRANSMIT THE FOLLOWING HARDWIRED SIGNALS TO THE CENTRAL SUPERVISING STATION: ZONE 1: FIRE e <br /> rvft,�rv.o.rooP1 WIRE TO BE IN ALARM /WATERFLOW, ZONE 2: SUPERVISORY, AND ZONE 3: TROUBLE. ee <br /> VICINITY MAP a e _ <br /> ADEMCO VISTA 128FB CONDUIT ® 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. - d <br /> -ER bbbbdbo5o 1 ® v Z w <br /> 0 <br /> Marysville eTTER Aa=�o�T ° w=� W <br /> J Q PROJECT CONTACT INFO E w a rc <br /> - - - -- ' ' Lake o O bbdd88388 r(In') <br /> ry <br /> 0 00000000 0 a <br /> Q Stevens OWNER/TENANT FIRE ALARM CONTRACTOR a <br /> c �TE>c»rRE1AN COE—ACCOUNTING DIVISION FIRE PROTECTION INC Yawn a <br /> #, �° s���� PO BOX 12130 17410 ASH WAY, Ste 8 goo e <br /> Possession 1� ` �T L �L� T 11� ='mrc0o <br /> O50 O O Ou0 Ou0 O O O OPO O O O O O O O O O O b 0 d O EVERETT, WA 98206 LYNNWOOD, WA 98037 <br /> Sound Everett PK CONTACT RUSSELL DANCE CONTACT DAVID MOW m w w G rc 30 <br /> PHONE : 425.257.8846 PHONE 425.290.9600 J <br /> RDANCE�EVERETTWA.GOV DAVID®FPISEATTLECOM >a a <br /> &171ERY o rc va a o <br /> 12VDC 12ANP REVISION RECORD <br /> 526 CODE INFO DATE/DESCRIPTION <br /> MUkllteo 2 AUTHORITY HAVING JURISDICTION : CITY OF EVERETT <br /> FIRE CODE : INTERNATIONAL FIRE CODE, 2018 EDITION <br /> Everett Fire BUILDING USE AND OCCUPANCY : (B) - SPRINKLED <br /> Department Station 7 FXI II\I('ADDRESSASLEFACP(ADEIVM VISTA 128FB FIRE PANF,L) AES-7707-88-ULP RADIO COIVMJNICATOR STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> North 522 CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> REMOTE SUPERVISING STATION : SECURITAS, INC. <br /> Lynnwood Creek PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION, INC. <br /> mds <br /> PARCEL NUMBERS 28051900402300 <br /> Mountlake 527 <br /> Terrace TYPICALVARM AND INSTAUATIONDETAI C INSTALLATION NOTES <br /> ftreline Bothell <br /> Cottage 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> Lake 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS—BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 02/15/2024 <br /> SYSTEM OUTPUTS 5. THE SYSTEM WILL BE 100% PRE—TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> Required Fire Safety Control PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> Central Supervising Station mm INSPECTION. <br /> Control Unit Annunciation ,� 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL <br /> ti �m DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> oc TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> o roo '0 m` me mC ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT 0 <br /> (NFPA72, SECTION 10.5.5.2). <br /> ST SE QD M <br /> 112TH .co'.q CO t4 <br /> C' 4 m 2 co LU 0o <br /> y LU 0o <br /> m ®° 2 aQ � DEVICE INSTALLATION REQUIREMENTS UJ Z Y <br /> y j W _0 Q Q <br /> ®z i°ymy�_0 Uj <br /> �`F�¢$` FIRE ALARM DEVICE INSTALLATION REQUIREMENTS U_ LU <br /> P a Q o . <br /> 4 O� O 3 o NOT PERMITTED W <br /> FACP y SUPPORT DIFFUSER HERE a• >_ LU J <br /> r' ,t O BRACKET <br /> C :�O Cm mQ Q J-0 D mZ J-BOX GRID $ <br /> KE RD UPSTAIRS WEIGHT ROOM <br /> as- oa oa yC^tee 3m a {J U LL ; <br /> VERVP __ IT T IT .. .. m 0 /A cV <br /> w FA DEVICE CEILING W S\l VER�KER .?m+?m.?m c c c'F Cm�`m`m DETECTOR SMOKE q. T <br /> \\- 4 V V `m `m tm `m �j 4 MINIMUM 3' r <br /> Q Q Q /� /� {� /� Q Q AW M FROM NOT PERMITTED 12" <br /> SYSTEM INPUTS B C D E F G H I HVAC DIFFUSERS HERE <br /> SMOKE <br /> 1 Manual Fire Alarm Pull-Station ♦ ♦♦ 1 H <br /> BE <br /> IMP Smoke Detectors ♦ ♦♦ 2 <br /> m 3 Wet&D Waterflow 3 <br /> W A a Dry ♦ ♦ ♦♦♦ J SHEET TITLE <br /> BE 0 MAX HEIGHT 92"A.F.F <br /> N 4 Unused ♦ ♦ ♦♦ 4 MIN HEIGHT 82"AYF ® 16d 3 <br /> O Z IL 5 Sprinkler Tamper ♦ ♦ 5 <br /> o A to 6 Unused ♦ ♦ 6 = FIRE ALARM <br /> A 0 z PROJECT DETAILS <br /> 7 Fire Alarm AC Power Failure ♦ ♦ 7 <br /> W8 Fire Alarm System Low Battery ♦ ♦ $ fifi•A.F.F fio•A.F.F puLL <br /> 9 Open dCircuitFl ♦ ♦ 9 ^s"A.F.F <br /> N10 Ground Fault ♦ ♦ 10 SHEET NUMBER <br /> A B C D E F G H <br /> K <br /> Not to Scale FA <br /> O.O <br />