EXISTING FACP <br /> f1simplex 41000 Fire Control Panels <br /> UL, CSFM Listed, FM Approved, XA Loop Interface to the 4100ES or 41000 Fire <br /> MEA (NYC)Acceptance* Alarm Control Panel, Module 4100-3115 <br /> MITI M- XA device loop, Simplex IDNetTM <br /> Class B or Class A addressable devices <br /> Allows the Simplex 4100ES or 41000 to operate <br /> as either an XA Loop Master Panel or an XA Loop ------- <br /> Data Gathering Panel device <br /> When operating as an XA loop Master Panel: <br /> • Connects to up to 255 input devices and up to 255 output - <br /> devices on a single XA loop to monitor, supervise,and device <br /> control <br /> • Monitoring status includes Normal,Trouble,or Alarm XA � <br /> • XA loop devices can be 4-wire if command output device <br /> functions are used,or 3-wire if used for monitoring only <br /> • XA loop devices appear to the 4100ES/4100U similar to <br /> IDNetTM addressable devices including custom labels <br /> with up to 40 characters <br /> When operating as an XA loop Data Gathering Panel: <br /> • Communicates status and receives control from the XA <br /> loop's Autocall compatible Master Panel <br /> • Control includes Acknowledge,Silence,Reset,and ------ <br /> device level commands <br /> • 4100ES/4IOOU operates as a stand-alone fire alarm <br /> control panel for its connected devices and appliances 4100-3115 <br /> 4100ES or 41000 panels a ui ed with Sim lex XA Loop <br /> p q pp p Module <br /> Network communications can send XA loop <br /> device information to other Network nodes <br /> 4100ES/41000 Fire Alarm <br /> - Control Panel(4100ES shown) <br /> System Flexibility.When a fire alarm system using 4100ES/41000 XA Loop Interface Block Diagram <br /> existing XA loop devices requires expansion,use of the <br /> 4100-3115 XA Loop Interface Module allows the <br /> expansion to include the capabilities of the 4100ES or <br /> 410OU fire alarm control panel. This module allows the Power Requirements <br /> host control panel to be selected to function as either the 24 VDC from expansion bay <br /> XA loop master controller(head end)or as a Data Voltage power supply if present;or wired <br /> Gathering Panel as an intelligent device on the XA loop to AUX(+)and AUX(-)from <br /> reporting to a remote master controller. Auxiliary 24 VDC in panel <br /> Current 570 mA @ 24 VDC <br /> Multiple XA Loop Interface Modules can be XA Loop Specification Reference <br /> installed in the 4100ES/4I OOU allowing a variety of <br /> system expansion situations to be satisfied.The Maximum Resistance 100 Q per wire <br /> 4100ES/4100U accepts up to a total of 30 modules of this Maximum Capacitance 1.5 pF wire-to-wire <br /> type which also includes IDNet modules,MAPNET II® 1.5 pF wire-to-shield <br /> modules,and VESDA®modules Current 500 mA <br /> On-Board LEDs are provided for service diagnostics to Voltage/Frequency 24 VAC,250 Hz <br /> indicate XA loop status,internal 4100ES/4100U Maximum Addresses per Loop 1255 <br /> communications status,and supervision status when General Specifications <br /> functioning as a master controller for the XA loop. Operating Temperature Range 32°F to 120°F(0°C to 49°C) <br /> For additional information,refer to Installation and Up to 93%RH,non-condensing <br /> Programming Guide 579-513. Humidity Range @ 90°F(32°C) <br /> *This product has been approved by the California State Fire Marshal(CSFM)pursuant to 4"x 10"(102 mm x 254 mm) <br /> Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7165-0026:251 Mounting module requires two vertical <br /> (non-high rise)and 7170-0026:250(high rise)for allowable values and/or conditions expansion bay blocks <br /> concerning material presented in this document.It is subject to re-examination,revision,and <br /> possible cancellation.Accepted for use—City of New York Department of Buildings— On-board terminal blocks for field <br /> MEA35-93E.This product was not ULC listed as of document revision date.Additional Output Wiring Connections wiring 18 to 12 AWG(0.82 mm2 <br /> listings may be applicable;contact your local Simplex product supplier for the latest status. to 3.31 mm2) <br /> Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety <br /> Products Westminster. <br /> S4100-0041-3 <br />