Laserfiche WebLink
} - gummary• • • <br /> of Special Inspection <br /> For this •ro'ect, check the re.uired ins•ections .er IBC Cha«ter 17 <br /> V (� <br /> to u5 <br /> 1 Special Inspections and tests Notes <br /> d � <br /> ❑ 1705.11 Special Cases <br /> ❑ 1705.2 Steel construction <br /> ❑ 1705.2.1 Structural Steel <br /> 1705.2.2 Cold-formed steel deck <br /> 0 1705.2.3 Open-web steel joists and joist girders <br /> CI 1705.2.4 Cold-formed steel joists and joist girders <br /> 1705.3 Concrete construction <br /> 1705.3 Concrete,reinf.&anchors(pre-or post-installed) <br /> 0 1705.3.1 Welding of reinforcing bars <br /> 1705.3.2 Material tests <br /> ❑ 1705.4 Masonry construction <br /> ❑ 1705.5 Wood construction <br /> ❑ 1705.5.1 High-load diaphragms <br /> 0 1705.5.2 Metal-plate-connected wood trusses <br /> ❑ 1705.5.3 Mass timber construction <br /> ❑ 1705.6 Soils <br /> 13 1705.7 Driven deep foundations <br /> 1705.8 Cast-in-place deep foundations <br /> 1705.9 Helical pile foundations <br /> ❑ 1705.10 Fabricated items** <br /> Q 1705.11 Special inspections for wind resistance <br /> ❑ 1705.11.1 Structural wood <br /> ❑ 1705.11.2 Cold-formed steel light framed construction <br /> ❑ 1705.11.3 Wind resisting components <br /> 13 1705.12 Seismic force-resisting systems <br /> 1705.12.1 Structural steel <br /> ❑ 1705.12.2 Structural wood <br /> ❑ 1705.12.3 Cold-formed steel light framed construction <br /> ❑ ❑ ❑ 1705.12.4 Designated seismic systems <br /> ❑ 0 1705.12.5 Architectural components <br /> ❑ ❑ 1705.12.6 Plumbing,mechanical and electrical components <br /> ❑ 1705.12.7 Storage racks ESR-3037 Simpson SB II Wedge Anchor <br /> 1705.12.8 Seismic isolation systems <br /> ❑ 1705.12.9 Cold-formed steel special bolted moment frames <br /> ❑ 1705.13 Testing for seismic resistance <br /> ❑ 1705.13.1 Structural steel <br /> ❑ 0 0 1705.13.2 Nonstructural components <br /> ❑ ❑ ❑ 1705.13.3 Designated seismic systems <br /> ® 1705.13.4 Seismic isolation systems <br /> ❑ 1705.14 Sprayed fire-resistant materials <br /> 0 1705.15 Mastic and intumescent fire-resistant coatings <br /> 1705.16 Exterior insulation and finish systems(IEFS) <br /> 1705.17 Fire-resistant penetrations and joints <br /> o 1705.17.1 Penetration firestops <br /> ❑ • 1705.17.2 Fire-resistant joint systems <br /> ❑ ❑ 1705.18 Testing for smoke control <br /> ❑ 1705.19 Sealing of mass timber <br /> *" Off-site special inspection is not required when approved by the building official. See MBP construction tip sheet <br /> Approved Fabricators'.online. <br /> GENERAL INFORMATION: <br /> crag:— .)2 of 5 <br /> • Obtain a building permit before starting construction. Form creat <br /> • This construction bulletin is intended to provide guidelines and a checklist of some special inspections that <br /> may be required per 2018 IBC.Additional information can be found at your local building department. =`"eCityG ov net <br />