Laserfiche WebLink
_.01ECEOVE -n <br /> ... „..,. . <br /> Ricker Residence Deck <br /> \\ MAR 2 2 2024 Structural Calculations L f <br /> By Jon Conner, P.E., S.E. <br /> CITY OF EVERETT s � <br /> Lakeview Structural Engineering <br /> Permit Services <br /> 206-914-9536 <br /> LakeviewS E@Outlook.com <br /> Design Criteria: <br /> 715 33'd St, Everett WA 98021 <br /> Lateral Loading parameters: <br /> Wind Load:N/A <br /> Seismic Load:N/A <br /> Other design values used: <br /> Occupancy Category: Residential <br /> Structural System: Wood framed shear walls <br /> Concrete: 2500psi with 40,000psi reinforcing <br /> Structural Timber: DFL #2 or better <br /> Glulam: 24F-V4 DF/DF <br /> Snow Loads: 25 psf <br /> Live Loads: <br /> Deck: 60 psf <br /> Dead Loads: <br /> Concrete: 150 pcf. <br /> Deck dead load: 10 psf <br /> Hot Tub dead load: 100 psf <br /> Design Codes and References: <br /> 2021 IBC, IRC for load calculations and general design criteria <br /> ASCE 7-16 for load calculations and general design criteria <br /> Concrete: ACI 318— 19 <br /> Timber: ANSI /AF&PA NDS-2018 for Wood Construction <br /> s11ALL C' <br /> ,\�,ov WAShrIiv�O4L <br /> I-t' T <br /> � • <br /> A ��- <br /> 1 <br /> A, pU 44672 447 44) <br /> °-k cTURAL% <br /> �4/ONAL V''G <br /> 3/19/2024 <br />