GENERAL FIRE ALARM SYSTEM NOTES FACP - (410 O U UPGRADE) TRANSPONDER PANEL #3 - 3RD FLOOR SYMBOL DESCRIPTION LEGE MODDEL BACK BOX `-`� <br /> © A DRESSABLE PUPULLLSTATION 2099-9795 W/ WIREMOLD BOX BY EC __' L <br /> 24 POINT 1/0 MAPNET CHANNEL #7 4 2099-9795 TRIM OR/ a 3/4'X 4 3/a'X 2 1/4' H � <br /> 1)FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED SPEAKER CIRCUITS SIGNAL CIRCUITS 499-90DI 4-SO 2 1/8-DEEP W/ U) N N N <br /> BY CODE,SPECIFICATIONS AND CONTRACT DOCUMENTS OR AHJ. SG RING BY EC C -0 0. <br /> o <br /> 169)3RD FLOOR B-WING NW SMOKE/FIRE DAMPERS 3RD FLOOR B-WING ADDRESSABLE DEVICES <br /> 2)ALL RACEWAYS MUST BE FREE OF MOISTURE CIRCUIT CIRCUIT DESORPTION CIRCUIT LOAD ZC- N. <br /> T D R T W EAKER a902-9776 4'SO 2 1/8'DEEP W/ 0 ` o00 o00 <br /> 170)3RD FLOOR B-WING SW SMOKE/FIRE DAMPERS 7-1 TO 7-11, 7-16 TO 7-24. 7-27 TO 7-33, a t t/2'ExT By EC MCI)N N N <br /> 3)REFER TO JOHNSON CONTROLS FIRE ALARM DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED SIG15 C-WING BASEMENT MECHANICAL ROOM 4 O.OW ZS.3 2N F R CEU S 0 E CIR UIT >O) <br /> 171) 3RD FLOOR C-WING SMOKE/FIRE DAMPERS 7-35 TO 7-39, 7-46 TO 7-47, 7-49 TO 7-50, N CEIUNG SPEAKER 4902-9721 4'SO 2 1/8-DEEP W/ <br /> DEVICE MOUNTING ELECTRICAL BOXES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SIG16 C-WING 1ST FLOOR 25.OW •'°1G1ER_Ta 1 1/2-EXT BY EC C Q m <br /> SIG17 SPARE O.OW 173 92 FLOOR C-WING SMOKE/FIRE DAMPERS 7-53 TO 7-54, 7-57, 7-60 TO 7-118, 7-120 TO 7-122 IC �� F'A <br /> PROPER INSTALLATION OF ALL DEVICES. SIG5 C-WING 2ND FUR SURGERY CORR AND ROOMS SPEAKER/STROBE 15/75cd 4903-9146 4'SO W/ O p U <br /> 173-192)SPARE <br /> 4)AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING. SIG18 SPARE O.OW SIG6-8 NOT AVAILABLE ,fig"°"""" �4 OR 4903-9301 1.5'EXT BY EC �U <br /> 5)UNRELATED(NON-FIRE ALARM)WIRING SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM SIG79 SPARE O.OW SIG9 C-WING BSMT MECHANICAL ROOM 4 STROBES 0sl S EGKEroR/S1R;BE 15cd 4903-9150 4905-99238 5/g'%2 3/4D O � w>�e• <br /> WIRING. SIG20 SPARE O.OW SIG70 SPARE � 0)U)UD Fn LT' <br /> TOTAL LOAD 2$.DW SPEAKER/STROBE 30cd 4903-9148 4 5/15-X 6 5/8-X 2 3/4D <br /> 6)ALL CONTRACTOR FIELD HIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER-UNITED AND SIG71 SPARE SPEAKER CIRCUITS WATTS �J,ay•'aura �e 4905-9923 <br /> NON POWER-UNITED WIRING REQUIREMENTS.REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. TOTAL AVAILABLE WATTS 100.OW MAPNET CHANNEL t8 LXI SPEAKER/STROBE 110cd 4903-9149 4 5/15-X 6 5/7'X 2 3/40 L0 In to f0 O <br /> 7)ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS ''pGhS Ta 4905-9923 <br /> to <br /> 51) 3RD FLOOR B-NANG-SIG45 �1W� UU) � HT <br /> SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS--T-TAPPING OF AUXILIARY CONTACTS 3RD FLOOR C-WING ADDRESSABLE DEVICES E WEATHERPROOF SPEAKER/STROBE 185ad ET70WP-24185W-FR I08-R F O (0 (O (0 N <br /> 52) 3RD FLOOR B-WING-SIG46 •.aGro am.rF U (0 (0 L0 L0 00 <br /> ZONE CIRCUITS AND SIGNAL CIRCUITS IS NOT PERMITTED. IDNET CIRCUIT DISTRIBUTION 53 3RD FLOOR B-WING-SIG47 8-1 TO 8-9. 8-13 TO 8-19, 8-25 TO 8-26, M <br /> 1,2)NOT AVAILABLE ) 8-31 TO 8-43, 8-46 TO 8-47, 8-50, 8-53 TO 8-63, SPAKEroR STROBE 15cd 4903-9356 4'SO BY EC O O O O O O <br /> 8)REFER TO FACP MODULE DIAGRAMS,INCLUDED WITH FACP,FOR SPECIFICATIONS AND 3) ELEVATOR RECALL 54) SPARE �1Q"ig i>d 0) 0) � � V)INFORMATION ON INDIVIDUAL PANEL MODULES. VERIFY ALL CONNECTIONS WITH A JOHNSON CONTROLS 8-65 TO 8-81, 8-83 TO 8-85, 8-90 TO 8-91 p• <br /> IDNET At 4) AUX POWER 55) 3RD FLOOR B-WING-SIG55 CHIMEE+/SSTRROO iBE 15cd CH7G-24MCW-FR 4-SO 2 1/0-DEEP BY EC <br /> FIELD TECHNICAL REPRESENTATIVE PRIOR TO TERMINATION. BASEMENT M1-7 TO Mi-11, Mi-244 TO MIO-248 1.5'EXT BY EC <br /> 9 ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS,SHORTS AND GROUNDS. 5) NOT AVAILABLE 56) SPARE w <br /> 1ST FLOOR M7-1 TO M7-6, M7-42 TO M1-63, M7-86 TO M7-103, 6) AUX POWER TOTAL WATTS MAPNET CHANNEL #9 M1WEATHERPROOF SPEAKER WT-1010-R WBB-R 2 2 m CO <br /> 10 ALL WRING SHALL BE LABELED AND TAGGED WEATHERPROOF STROBE 15/75ed WM3T-2rFR w w 01 <br /> M7-223 TO M7-224, M1-226 TO 1-243 •weswr.auro ala.TF <br /> 11 ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION AND MAKING ALL FINAL 7) 1ST FLOOR DOOR HOLDERS WATTS PROVIDED 3RD FLOOR A-YANG ADDRESSABLE DEVICES t2 U7 N w <br /> 2ND FLOOR M7-12 TO M7-40, M7-64 TO M7-85 8) 2ND FLOOR DOOR HOLDERS 9-1 TO 9-44 MLGCroAND_ELA WALL SPEAKER/STROBE 499-9151(Red) 4'SO 2 1/8'DEEP BY EC <br /> CONNECTIONS PRIOR TO JOB CHECKOUT AND FINAL TESTING BY A JOHNSON CONTROLS FIELD 3RD FLOOR M7-150 TO M7-157 9) 3RD FLOOR DOOR HOLDERS H 4 OR 4906-9153(White) 1.5"EXT BY EC <br /> TECHNICAL REPRESENTATIVE. CALL A MINIMUM OF 5 DAYS IN ADVANCE TO SCHEDULE ROOF M7-249 TO 256 4TH FLOOR A-WING ADDRESSABLE DEVICES �° MNgTICroANDELELA CEIUNG SPEAKER/STROBE 4906-9154 4-SO 2 1/8-DEEP BY EC U) V) <br /> A JOHNSON CONTROLS TECHNICIAN AT(206)777-4860. 10)4TH FLOOR DOOR HOLDERS . (n (n w w <br /> i 9-50 TO 9-105 1.5'O 2 BY- U) U <br /> 12)ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MAKING ALL ARRANGEMENTS FOR m"a^ Fla^'2 m a M L�CroANDE i, Ec A AKER OBE E70-24MCW-FR 1. SO 2 BY DEEP W/ q <br /> INSPECTION,TEST AND CERTIFICATION OF THE FIRE ALARM SYSTEM BY ALL APPROPRIATE 8 m - a, - i ~ 1.5'EXT By EC <br /> AUTHOR TIES. ZONE SCHEDULE o box AUXILIARY CIRCUITS _MULTICAANDDE A WALL STROBE 4906-9101 4'SO BY EC <br /> 13)UPON WRITTEN REQUEST,JOHNSON CONTROLS WALL PROVIDE WRITTEN INSTRUCTIONS REGARDING THE BATTERY CALCULATIONS $ g MUuCi�A aDELA CEILING STROBE 490E-9104 SG BY EC <br /> APPROPRIATE WIRE CABLE FOR INSTALLATION OF THE EQUIPMENT SYSTEMS IDENTIFIED 1)MEDICAL OFFICE BUILDING FIRE ALARM a -8 S a E 23) 3RD FLOOR B-WING DOOR HOLDERS t <br /> / / () DOES THE SYSTEM HAVE AN EMERGENCY GENERATOR THAT <br /> 2-7) SPARE R z, _ 24 3RD FLOOR C-WING DOOR HOLDERS L❑ STROBE 15cd 4904-9168 4'SO BY EC <br /> IN THESE DRAWNGS. JOHNSON CONTROLS SHALL NOT BE RESPONSIBLE FOR PROBLEMS OR DAMAGES MEETS NEC 700.701 ❑YES M NO4 ) ,r ,E,a <br /> 8) C-WING 2ND FLOOR OR PHARMACY g JY g _ g 25 4TH FLOOR C-WING DOOR HOLDERS STROBE „a"' R°"w4 <br /> RESULTING FROM THE USE OF WiRE/CABLE OTHER THAN THAT WHICH HAS BEEN IDENTIFIED g � P P P $ � d P e g R ) ©�STROBE lsca asorana OR a'so BY EC <br /> IN WRITING BY JOHNSON CONTROLS FOR A SPECIFIC APPLICATION. HOW MANY HOURS OF BATTERY STANDBY ARE REQUIRED? 65 45 � " o 45 26) FL3 A-WING NURSE LIGHT SMOKE RELAY .wece"wa-akaa 4904-9176 <br /> 14)ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ❑4 ■24 ❑48 ❑60(4 HRS.MIN.W/EMER.GEN.) 27-30)SPARE V) <br /> '$ S� 'q F o g o ©�STROBE 15cd(FREE-RUN/SYNCH) 4904-9176 4'SO BY EC 0 <br /> ALARM AND LOW VOLTAGE WIRING. o 0 0 0 0 6 6 6 6 6 6 6 _ wesceP waaro Ciao a Z <br /> STANDBY TOTAL ALARM TOTAL © STROBE 30cd 490r9174 4'SO BY EC 3 <br /> CITY PART# DESCRIPTION CURRENT(A) STANDBY(A) CURRENT(A) ALARM(A) `wa 4 Of <br /> Signal Circuits-Transponder 43 Volta a Drop •STROBE <br /> waasro aOf <br /> TI ARCHITECT: BNH ARCHITECTS � Current �'--� g- © STROBE 75cd 4904-9169 4'SO BY EC p <br /> EVERETT, WA 1 EXI NG FIRE ALARM CONTROL PANE. zngo Ingo 13.070 13.2370 6 11 57 ) 3rd Floor B-Wing NW 0.978 750 2.25 •wese-eaoAro awa..F <br /> 1 EXISTING PERIPHERAL DEVICES 0.2130 0.2130 4.3M 4.3 2 4 2 58 ) 3rd Floor B-Wing SW 0.438 49 0.54 ITO <br /> OR STROBE 15/75 eel 4904-9137 SG WIREMOLD BY EC p <br /> 2 4088-875CT DETECTOR 0.0o0p0 320 2 0.0 0.0g40 4 4 8 59 3M Floor C-Wing Nash 0.904 905 2.51 1} r <br /> O 3 W p1 0. <br /> 2 49W-9146 SPEAKER STROBE 15/75cd 0.0000 0.0000 a0m aim O <br /> ) <br /> 2 4904-9137 STROBE 15/75ad a0000 0.0000 a0m, aim 4 8 60 ) 3rd Floor C-Wing South 0.692 805 1.71 STROBE CEILING 15ed 4904-9183 SG BY EC U <br /> FIRE ALARM SYSTEM TI DESIGNED BY: JOHNSON CONTROLS s 49w-917B STRaeE mad 0.0000 0.0000 aoaza o.sssa 2 1 10 61 ) 4th Floor C-Wing North 0.865 630 1.67 � 'w�^m„aGw--0 3 � W <br /> SEATTLE, WA 4 408E-4756 DUCT DETECTOR MW24 0.008E 0.0150 0.0600 2 7 62 4th Floor C-Wing South 0.600 750 1.38 MULTICANDELA STROBE RSS-24MCW-FR 4'SO BY EC = p U) <br /> 4 4098-8843 DUCT RELAY 0.0000 0.aaw a015o o.osoo ) �,®..ws.�sr ra�rzs <br /> 3 1 7 63 ) 3M Floor A-Wing West 0.755 370 0.86 am.r F e crsoaA ` 2 w U 00 <br /> Total Slmdby= 2-5918 Total Al- 1&8360 1 7 64 ) 3M Floor A-Wing East 0.510 385 0.60 ® WHEELOCK SYNC MODULE SM-12/24-R 4 11/18'BOX DEEP BY EC O Q w Of <br /> FIRE ALARM SYSTEM TI INSTALLED BY: VECA ELECTRIC 65 ) SPare 0.000 395 0.00 2 I- F- U <br /> SEATTLE, WA Time(Him.) ) ® SYNCH MODULE 4905-9938 „,/OOVER1BY•ECE� <br /> Total Standby Current Required= 2.5918 X 4.0000 10.3672 6 3 66 4th Floor A-Wing East 0.972 325 037 } <br /> Total Alarm Current Required- 18.8360 X 0.0830 1.5633 9 1 1 1 67 ) 3rd Floor B-Wing East 0.972 320 0.95 0 / W U W 0 <br /> TRUEALARM SMOKE SENSOR 498-9789 W 4'OCT BY EC U <br /> fib ) Spore 0.000 O.OD •wauro Amsss.wu;w,nwrl 498-9789 BASE q Q p p <br /> Tot al= 11.9305 12 0 12 8 1 1 60 0 15 1 4 1 Total 7.254 1 .TRUEALLARM SMOKE SENSOR 498-9714 W/ 4'OCT BY EC T. M <br /> EQUIPMENT FOR FIRE ALARM SYSTEM SUPPLIED BY: JOHNSON CONTROLS 20%Depletion Factor 2.3861 a•��u AaAaRewe„~f 498-9792 BASE o Of <br /> SEATTLE, WA Total Amp/Hour Required 14.3166 ® TRUEALARM SMOKE SENSOR W/RELAY 4 a <br /> 4 BASE 4-OCT W/1.5-EXT BY EC C = _ 0 0 2 <br /> Total Amp/Hour Batteries Provided (1)Set 18.0000 2-8 ro 49 098-9789 8-9789 RELAY �j,,, <br /> WASHINGTON STATE ELECTRICAL CONTRACTORS NUMBER: JOHNSCP831PR BATTERY CALCULATIONS - TPR #3 p° TRUEALARM SMOKE DETECTOR 498-9701 W/ 4'OCT BY EC } } I <br /> •rooks Aoo�ssraw aw¢# 498-9785 BASE m m <br /> •7FElBE DRAWNCMS DO NOT ffilF'6t8g)E llf CONTRACT DRAWN AND BPECFCAT10N8, 4 O X J 0 0 0 0 <br /> TRUE�A TLARMSSMMOKE DETECTOR 498-9707 W/ 4'OCT BY EC U U O O O <br /> Does the system have an Emergency Generator that meets NEC 700.01. No <br /> "'w1LT a 498-9701 BASE U U O O O <br /> THEY ARE MENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH Q'TRUE�A TLAR�S�q(�TDEIECTOR 498-9707 W/ 4'OCT By EC N N � � Li <br /> THE CONTRACT DOCUMENTS.THEY DO NOT MODFY THE CONTRACTORS 08"TIONs TO TRANSPONDER PANEL 1 •w 498-9785 BASE p <br /> CONFORM TO llf PRQIECTB ORIGINAL DESIGN CRfT6WA How many hours of battery standby are required? 4 49a-9792 RELAY > > I- F- Z <br /> NEXT TO FACP ( /Emergency ) ®s TRUEEAALPAr Nor SMOKE DETECTOR 498-9701 W/ 4'OCT BY EC J J r- I" N <br /> 4 hours minimum Generators Mw1wr# 498-9785 BASE <br /> �r2 SMOKE PDETECTTOOR BY OTHERS BY OTHERS <br /> -6 '°"e t N N N N � <br /> n Total Alarm Total •w� way. N N C4 <br /> Descri ion 0 a TRassice RM HEAT DETECTOR498-9785 W/ 4'OCT BY EC �+7 I l <br /> Oty Port P Curets A Stan A Current A Alarm A ,w m waG W 49a-e7e5 BASE O In <br /> t AUXILIARY CIRCUITS / c 04 m 0 Lo <br /> .N EIACA�"' <br /> E: 1 4100-8019 Fire amen Control Panel 1.5440 1.5440 10.7400 10.740D �uE�ALR gcHEi�AiwiEt;ctaft �8-97 9 BASE 4'OCT BY EC I I <br /> 15)BLDG C 1ST FLOOR DAMPERS L PROGRAM INDICATES SIG 3 SPEAKER CIRCUIT AND SIG 7 STROBE CIRCUIT ® 1 All audible sable Devices this Panel 0.0000 0.0000 7.2970 7.2970 X <br /> 01 }R ICES THIS AREA WHICH DOES NOT MATCH THE RECORD DRAWINGS. E)X TR GALLARMDUCT SENSOR 498-9753 OR/ SELF-CONTAINED <br /> 16-22) SPARE 4 2088-9008 Remote Relay 0.0000 0.0000 0.0150 O.OSOD wxq 409-9756 <br /> Sequence of - - x W E _ o INFORMATION IS BASED ON RECORD DRAWINGS PROVIDED BYOTHERS.EXISTING o in p <br /> t o 8 498-9751 True Alan In Duct Smoke Sensor 0.0024 0.0192 0.0300 0.2400 TRUEALARM IN-DUCT SENSCI2 49g_g757 SELF-CONTAINED X <br /> Operation - UIT LOAD IS UNKNOWN AT THE TIME OF DESIGN.ACTUAL NOTIFICATION aaaAro Aaae--•-.CT SE <br /> w+ o w o vEi c IANCE CIRCUIT DISTANCES AND EXISTING FIELD DEVICE QUANTITIES PER 8 498-9756 TreaAlarm Duct Smoke Sensor 0.0024 0.0192 0.0150 0.1200 <br /> E ; o ®a DUCT DETECTOR RELAY 498-9843 4-SO W/SG&COVER BY EC <br /> Y .s o V ; UIT ARE UNKNOWN. 0.0000 D.Do9 DRAWINGS REVIEWED BY: <br /> De TRUEALARM SMOKE GET.W/RELAY 498-9701 W/ 4'OCT BY EC <br /> E ;N „ W o �. SIGNAL CIRCUITS Total Stand a ..Cairo Apaazasa 498-9785 BASE <br /> Rn - x°' o' rk rn CCOMMODATE THE T.I.WORKA SINGLE DEVICE WAS REMOVED AND b)'= 1.5824 Total Alarm- 18.4570 - °E'^a v 498-9822 RELAY Eric Beck,CET <br /> Activation of Local AlamI at FACP CATED ON THIS CIRCUIT WITH NO SIGNIFICANT CHANGE IN CABLE DISTANCE O DOME LIGHT BY OTHERS BY OTHERS NICET#14807727) BLDG C 1ST FLOOR OBSERVATION AREA STROBES ANDELA WHICH SHOULD NOT CHANGE TO OVERALL LOAD OR VOLTAGE DROP Time(Hm) Fire Alaml Systems,Level III <br /> LCD Display&Audble Indication X X X X X X X 28) BLDG C 1ST FLOOR TRIAGE STROBES ECIRCUIT. Total Standby Current Required= 1.5824 X 4.0000 6.329EX:( REMOTE LED 298-ae9 SG WiRENOLD BY EC <br /> Activation of Local Alarm at 29) BLDG C 1ST FLOOR ER WEST&SOUTH 0 REMOTE LED W/TEST 298-98M SG BY EC <br /> Annunciator X X X X X X X 30) BLDG C 1ST FLOOR ER NORTH &EAST E TIME OF INSTALL JCI TECHTO FIELD VERIFY VOLTAGE VALUE AT THE ENDOF Total Alavn Current Required= 18.4570 X 0.2500 4.6143 SUPERVISED IAM 490-9001 4-SO W/SG&COVER BY EC <br /> Activate Audible�sible Devices Floor 31)FLi C-WING CT SCAN NORTH RESISTOR FOR EACH CIRCUIT TO ENSURE IT IS WITHIN THE CORRECT <br /> of Alarm/Floor Above/Floor Below X X X X X X X 32) FLi C-YANG CT SCAN SOUTH ATING WATTAGEMOLTAGE RANGE.REDLINE ALL VALUES FOR RECORD Total= 10.9439CONTROL IAM 21&0-9163 ht1/16'w/1.5'EXT.BY EC <br /> ING PURPOSES AS WELL AS TO VERIFY NFPA 72 AND THE MANUFACTURES ® SIGNAL ZAM 2190-9162 rtt/16-W/1.5'EXT.BY EC <br /> Release Door Holders 37) GENERATOR BLDG STROBES MUM OPERATING REQUIREMENTSARE MET. 20%Depletion Factor= 2.1888 <br /> X X X X X X X 38) SPARE w❑` 8 AMP-RELAY IAM 490-9010 4'SO BY EC <br /> 69) BLDG C FL5 MECH RM5 Total Amp/Hour Required= 13.1326 w❑ RELAY IAM 490-9002 4'SO BY EC <br /> Fan Shutdown X X X X X X X X 70) SPARE DUAL RELAY IAM 490-9010 4'SO BY EC <br /> 71)SPARE Total Amp/Hour Batteries Provided= (1)set 33.0000 ® FLOW SWITCH BY OTHERS BY OTHERS <br /> Close Smoke/Fire Dampers X X X X X X X X 1 72) SPARE I TAMPER SWITCH BY OTHERS BY OTHERS <br /> Primary Elevator Recall MD 24 MCC MAGNETIC DOOR HOLDER 2081 SG BY EC <br /> Recall to First Floor X X SPEAKER CIRCUITS ® DOOR HOLDERS 2088-9559 OR/ SG BY EC <br /> 2088-9608 �✓yY' <br /> Alternate Elevator Recall © DOOR HOLDER DH24120FPC SG BY EC µ4 <br /> Recall to Second Floor X 33) BLDG C 1ST FLOOR TRIAGE <br /> 34) FL7 C-NING CT SCAN ® DOOR HOLDER BY OTHERS BY OTHERS 1-4 <br /> Transmit Alarm Signal To X X X X X X X 35) GENERATOR BUILDING TRANSPONDER PANEL #2 VOLTAGE�50MIwW I] DOOR HOLDER/CLOSER BY OTHERS BY OTHERS o <br /> Central Station Monitor 36) FLR5 A-C CROSSOVER &MECH RM5 circuit Deecdpem Lead x ® DOOR POWER SUPPLY BY OTHERS BY OTHERS U <br /> Trouble Indication at FRCP 73) BLDG C&A-C CROSSOVER N7-1 57H Fl.STROBES $M,10.36oN 1.2'7>:Drop SMOKE/FIRE DAMPERS BY OTHERS BY OTHERS <br /> or- <br /> X 74) SPARE A-WING I D F ROOM 2 A 1 B Y MAIN FACP NI-2 FL BES SIG2 0.540A 432z ® SMOKE DAMPERS BY OTHERS BY OTHERS <br /> N1-3 2ND FL STROBES SIG3 O36a4 1.71% ® FIRE SMOKE DAMPERS BY OTHERS BY OTHERS <br /> Trouble Indication at Annunciator N1-4 7N FL-ROOF DECK WP STROBE SIG4 0.4204 2.475 A❑ REMOTE RELAY 20N-9008 SELF-CONTAINED <br /> X SIGNAL CIRCUITS 6800 To al P4 <br /> Transmit Trouble Signal To X MAPNET CHANNEL 144 ® SYNCH.MODULE 4905-9914 OR/ SG W/cOVER BY EC EW-I <br /> Central Station Molitor POIN6 SHOWN N rIAUC TEXT REFER TO DISTNG DEVICE. 4905-9938 4-SQ 2 1/8-DEEP BY EC <br /> O LCD z DISPLAY 4603-9101 6-GANG DEEP BY EC <br /> Supv Indication at FACP X X 4-1 TO 4-57, 4-60 TO 4-104, 4-106 TO 4-114 Missal NMW lead mad Mad Hood mad! 75� NI-1 9° P ® MINIPLEX TRANSPONDER 4100-8019 OR/ 52.125'X 25.75'X 6.75' Fr,-1 <br /> F F F F F L L sYN CURRENT DIST. ft VOLTAGE DROP Allowable X gyp. 333x Wiro Res.Per Ft D.a02e22 a sou Celsius 4100-960o Wj <br /> Supv Indication at Annunciator X XCHIME <br /> 8 S ❑ ❑ W#e� Mn.-valtai. 18.vdc ® SCU ANNUNCIATOR 4602-9101 6-GANG WREMOD BY EC OR <br /> Sterling gs, 24.vdc 9s P 1.271 1 <br /> 39)COLBY OFFICE INFlLL STROBES Omit Capacity 2A I--I <br /> Transmit Su v Signal To ° ® DNET NAC EXPANDER PANEL flog-9201 13.5'X 18.25'X 4.25' <br /> P 9 X X 40)1ST FLOOR LAB STROBES Qi <br /> Central Station Monitor 41) 2ND FLOOR GI LAB STROBES Distance Device ge m ® FIRE ALARM CONTROL PANEL EXISTING EXISTING <br /> 42 2ND FLOOR GI LAB STROBES Device PID Ss8W9 Fed Curets Drop Doi I--k <br /> N1-1-1 4903-9150 0.090 IODO 24.00 Q <br /> 2 3 3 43)FL1 SLEEP ROOMS NAC PANEL 0.896 355 1.04 N1-1-2 4903-9150 0.090 O.ODO 24.00 <br /> SCOPE OF WORK 3 4 3 44)FL7 SLEEP ROOMS NAC PANEL 1.045 375 1.28 N1-1-3 4803-9150 am O.ODO 24.00 <br /> 61-62) SPARE N1-1-4 4903-9150 Tomlc (Fed) <br /> o.36W� 0.102 23.E <br /> MODIFY EXISTING FIRE ALARM SYSTEM: TENANT IMPROVEMENT IN THE WIRE CODE <br /> 2ND FLOOR PHARMACY. RELOCATE DEVICES AND CONNECT AS SHOWN. EI <br /> N1-2 ga ALL WIRING TO MEET CURRENT NATIONAL ELECTRIC E- <br /> Be <br /> POINT I/O MAPNET 446 CODE ARTICLE 760,300.310.370,725 AND ALL RELATED r, W <br /> SECTION CODE REQUIREMENTS <br /> Wks <br /> W /�J <br /> Allowable x argil. logo Mo.DrviRea.Per FL 0.002822 0 50 Cddue E� I�-I <br /> Wire Gauga: n. a Vdta9w 16.Mc <br /> THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR CT SCAN SMOKE/FIRE DAMPERS 6-1 THRU 6-37 Starling Voltage 24.vdc x Voltage Drop 48YS U) <br /> 6-40 THRU 6-85 Did Capacity 2A LETTER CITY COLOR/TYPE SIZE FUNCTION �•4 <br /> TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM Distance WasNormal m ° A 2 BLACK/ORANGE TFN 16 ZONE � Ey W <br /> THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE Device PID setting Feet Current Oro DeMae a 4 RED/BLUE THHN 16 ZONE LOOP w <br /> WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM NI-2-1 49D3-8150 0.090 a.aoo 24.00 W W <br /> N1-2-2 4903-9150 0.0900.0gg 24.00 N by <br /> DEMOLITION WORK. N1-2-3 4903-9150 OA90 O.ogo 24.ao C 2 RED/BLUE THHN 14 STROBE F4 F4 <br /> N1-2-4 4903-9150 am 0.008 2A00 D 4 RED/BLUE THHN 14 STROBE LOOP <br /> N1-2-5 4803-9150 0.090 0.000 24.00 ,rI W 6 <br /> W0t/a08 NnC N1-2-6 49W-9150 455 0D90 0.231 73.77 E 2 BROWN/YELLOW THHN 14 DOOR HOLDERS �y nr�� Q p., <br /> BmmT rdd wma reed T bW 455 FL 03401 F4..1 I_H pD <br /> uedr our D.abeen oa.A Rma7 a.md Abe, .7 <br /> NOTES: Penal seetewd H NEST PENN D975 18 SERIAL COMMUNICAT ON > 0 p <br /> - FIRE ALARM DRAWINGS ARE SCHEMATIC ONLY. NOTE: flare- 1 1 +Cos Nn we onDm.l2o we mreo lama Clasp or reo 2 RED/BLACK THHN 14 N U <br /> . Pawl medr omso a11Wo NI-3 9° P <br /> - ALL CABLE SUBSTITUTIONS MUST BE APPROVED BY SEQUENCE OF OPERATION SHALL REMAIN THE SAME xWnmBon AN_ sdWN U 1 TW/SHID PAIR 18 SPEAKER V <br /> r, <br /> JOHNSON CONTROLS ENGINEERING IN WRITING. /wY91m a ism wa Romara m AIR Moo m aooao assail ooMo Laloo Allowable It Drop: 33.3% Wme Rea.Pa FL D.DDze2z o sou Celeies 44 W <br /> ERaaP-sataW-m t XFalaaaaa 1. o.0000 a.DDDD - a4aro W&e Gougs, vim.W.Willing. <br /> K 2 TW/SHLD PAIR 14 SPEAKER LOOP <br /> - NOTE: MOUNT HORN/STROBES, SPEAKER/STROBES AND Pwwww rove o.0o00 +.- Smnmg-9- 24.vdc ■-9.-P 1.7171 a APPROVED BY: <br /> STROBES AT 80" TO BOTTOM OF DEVICE. Swwwo rem•: swift aseeo -1 1- Od Copmity 2A N 2 WEST PENN D975 18 MINIPLEX TRANSPONDER z <br /> R 16 z <br /> OF DEVICE.LINT PULL STATIONS AT 48"TO TOP Device qg Sete g Faep Current prop operation pe,;c, p z RED/BLACK AITHHN 14 24VOC POWER a DRAWN BY: <br /> - ALL SHIELDS ON THE SAME MAPNET CHANNEL SHALL ELECTRICAL CONTRACTOR a-do, sMmM Abe, Alen Dinke 490.PID (Fd) 0.090 O.ODO 24.Ooposon, <br /> g <br /> BE TAPED TOGETHER AND BE FREE OF OPENS, -ELECTRICAL CONTRACTOR IS TO SCHEDULE A PREUMINARY SITE sa.e1 NL Pe�.w i9ar(w m m.b,g,'1.„t °n„i1 r°M °ns" ia1tl NI-3-2 4903-9150 0.09D O.ODO 2401) R 2 BLUE/WHITE TFN 16 REMOTE LED W/TEST J.D.B. <br /> SHORTS, AND GROUNDS. MEETING WITH A JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. Owe ouMo + N1-3-3 4900-8150 0.090 O.ODO 24.01) 2 PINK TFN 16 <br /> THESE MEETINGS ARE FOR REMEWNG EQUIPMENT LISTS, NI-3-4 4903-9150 270 0.090 0.1W 23A o DATE: <br /> - DO NOT EXCEED 2500 FT OUT TO FURTHEST DEVICE- .edsww a.aN�„ sw 1o0d omw +mRI Totolm 270 R.0380A s z PURPLE/WHITE THHN 14 SMOKE/FIR <br /> DAMPERS <br /> MAXIMUM 10,000 FT ON MAPNET CHANNEL. INSTALLATION PROCEDURES,AND PROVIDING ANSWERS TO QUESTIONS su caaa.aled PonPlwrd oedaw 0 .oaas -apple .04038-O.e000 w 9/12/96 <br /> - PULL NEW WIRING TO EXISTING TPR#3 LOCATED ON 3RD FLOOR. RELATIVE TO SYSTEM INSTALLATION. Mw ,Alike owkr.,way cm.aaaiaam aawM a .acowre -axas .aox000-am T T BLUE/WMITE TFN 16 REMOTE LED <br /> sub Total 001150 1.11650 w SMTE NUMBER/PROJECT NUMBER <br /> - CONNECT SPEAKERS TO SPARE SPEAKER CIRCUIT 8 -PLEASE ALLOW A MINIMUM OF FIVE WORKING DAYS ADVANCE NOTICE aaaL„bI. NI-4 Voltage p X 1 WEST PENN 0975 18 ADDR.MAPNET DATA LINE <br /> #4 spew Pane mPaab m a .o -o.0000 .o.a.0000 458-400892 <br /> IN TPR. TAP SPEAKERS AT 1/2 WATT. TO SCHEDULE A TECHNICAL REPRESENTATIVE. Tent eaam +meo Allowable IL Dmp:� Wire Res.Per P. o.aoze2z a 5G Celsius Z 2 BLUE/WHITE TFN 18 NURSE CALL INTERFACE <br /> - CONNECT STROBE CIRCUIT TO SPARE STROBE CIRCUITS 55 Be 56 Wire goings: Min.Device v 1). 18.Mc <br /> skwmy 1lwe- 34 xw .amw -2A(00 9wdby M Starling Vdla9K 24vdo X Voltage DraP 2.47X <br /> IN TPR #3. -TO SCHEDULE A MEETING PLEASE CONTACT OUR OPERATIONS DEPARTMENT wwa,ilia.= s Ma ocesss.ises =0.1554 wwm h Cld Capacity 2A NOTES: <br /> AT(206)777-4860. Vohs <br /> - CONNECT ADDRESSABLE DEVICES TO MAPNET CHANNEL#7 IN TPR #3 tmuiasi W. .on 1-ot,= as Normal1) TAG AND IDENTIFY ALL ZONE WIRES NTH ZONE NUMBER. <br /> -DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET 2,as4 BwtaKe Davice 2) TAG AND IDENTIFY ALL SIGNAL CIRCUIT WIRES WITH it SHEET NUMBER: <br /> - DO NOT USE FACP AS A TERMINAL CABINET. Bone,Nede,e FaMw- wi1 a4sr OaMcs PID Seltlng Fad Curets IAsO oevire SIGNAL CIRCUIT NUMBER. <br /> MaYnun Bone,Regaved zmr-gm e2AH(zr) zsN6 N1-rt Ef70WP-2418911-Fit 185cd 250 0.420 0393 23.41 3) TAG AND IDENTIFY ALL ANNUNCIATOR'WIRES. It! <br /> T.W.250 PL0.42M U FA-C OV-0 2 <br /> Botkwy sarpMd roar-eta s.wl z. <br /> I <br /> Ile k <br /> it LL <br />