My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 2ND FLOOR 2024-12-31
>
Address Records
>
COLBY AVE
>
1321
>
2ND FLOOR
>
1321 COLBY AVE 2ND FLOOR 2024-12-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/31/2024 1:07:08 PM
Creation date
11/6/2024 8:08:11 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� o <br /> m <br /> 1 j 000 <br /> J <br /> C O N�NNN <br /> 0 000 <br /> N >� <br /> CQN <br /> C 0 zg w <br /> ZuRt� <br /> 0 @ °� <br /> � 2U)ME <br /> DEVICE MOUNTING HEIGHT REFERENCE TrueAlert CONVENTIONAL APPLIANCES END OF LINE RESISTOR CODES Lo It 0 0 n <br /> PER NFPA 72 SIMPLEX 4906 SERIES WALL MOUNTED SPEAKER/VISUAL rn rn co Lo 00 <br /> ELECTRICAL BOX IMPORTANT o 0 0 0 0 o <br /> VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS WALL MOUNT BACKBOX INSTALLATION �' 04 04 Lf) � U) <br /> 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP OF A/C SUPPLY SURFACE MOUNT ADAPTER SKIRT HEIGHT REFERENCE NOTE:REFER TO PANEL/MODULE AND DEVICE p' cD cD c0 c0 c0 <br /> LENS FOR 11OCD STROBES WITHIN i6'OF THE PILLOW OR RETURN 3-3/16"(81mm)DEEP. INSTALLATION INSTRUCTIONS FOR PROPER <br /> THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS CONDUIT CUTOUTS ARE PROVIDED Q 2975-9145 BOX TERMINATIONS. W <br /> V. <br /> 2. 177CD STROBES,USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24'(610mm) DIFFUSER Q 4" In On <br /> BEEN REMOVED FROM THE 2010 EDITION OF NFPA ON ALL FOUR SIDES. Qp O OUTLINE �.l w w <br /> MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY IS TO -O REF. BAND NUMBER E7 CY <br /> COMPENSATE FOR A POSSIBLE SMOKE LAYER T(914mm) q NOTE:MEASUREMENTS SHOWN O MODEL f) WATTS CIRCUIT TYPE FIRE ALARM PANELIMODULE C! 1n U) W <br /> (102mm) APPLIANCE&LENS p NUMBER B 2 3 4 6 <br /> MINIMUM CEILING ARE TO THE CLOSEST EDGE OF Q 1-12 4081-9001 733-892 22K RED RED RED GLD N/A 112 ANNUNCIATOR(4300) 4004,4010(TROUBLE) <br /> THE DETECTOR ASSEMBLY 4"SQUARE BOX .. 4 ,H 4004',4004 0, <br /> —� - OUTLI 4081-9002 733-893 3.3K ORG ORG RED GILD N/A 1 WATERFLOW,TAMPER ETC. 41000,ZAMs N N <br /> FORCEILING HEIGHTS LESS THAN 86"(2180mm),THE NFPA 72 AUDIBLE APPLIANCE 6"MIN CEILING MOUNTED 4" DO NOT BRING THE CONDUIT THROUGH THE 24 PT.IOSWITCH SUPV. 4605-740141005ERIE$ N U) <br /> VISUAL LENS MOUNTING HEIGHT SHALL BE WITHIN 6' (152Amm MIN)BELOW FINISHED CEILING SMOKE/HEAT (102mm) REAR OF THE ELECTRICAL BOX. 4081-9003 733-896 4.7K YEL VT RED GILD N/A 1/2 CURRENT LIMITED N.O.INIT., 40901DNET JAM(EOLR) q <br /> DETECTOR STRIP THE LEAD INSULATION TO 3/8"MAX. NOTIFICATION(DACT) 2080_9024 <br /> (150mm)OF THE CEILING. �— - <br /> • N/O INITIATING PULL,SMOKE,HEAT, <br /> ACCEPTED HERE M (305mm) 4081-9004 733-886 6.8K BLU GRV RED GILD N/A 1/2 2190-9MA MAP(TROUBLE) <br /> PT I 0 <br /> HEAT DETECTORS MAXIMUM TO TOP OF SENSOR o W.FLOW,TAMPER ETC q-20MAZAM(TROUBLE) <br /> CURRENT LIMITED N.O.INITIATING <br /> AUDIBLENISUAL& AUDIBLE ONLY NEVER HERE 4081-9005 733-984 1.SK BRN GRV RED GILD N/A 1/2 4090-90011DNET LAM <br /> TO EXIT DOOR WIRING INPUT TERMINAL AND SPKR STRB SPKR STRB <br /> INLINE) <br /> VISUAL ONLY WALL MOUNTED (+)(- - + -) (-(+) 4081-9006 733-890 560 GRIN BLU ERN GILD N/A 1 N.C.INITIATING(EOLR) 4005•,4090-90011DNET LAM <br /> APPLIANCES 5'(MAX.) SPEAKER TAP SELECTION ARE 4100'4 <br /> 1000 <br /> SMOKE/HEAT DETECTOR <br /> (1524mm) ACCESSIBLE FROM REAR 4081-9007 733-891 1.2K BRN RED RED GILD N/A 1 N.C.INITIATING(EOLR) 4005 <br /> SYNCHRONIZE MORE THAN SPEAKERASSEMBLY 40 ,4 , ,4 9,4010, to <br /> 4081-9008 733-894 10K BAN BLK OFIG GILD N/A 1/2 NOTIFICATION U <br /> TWO APPLIANCES IN ANY REMOVABLE COVER STROBE ASSEMBLY 4100,41000 Z_ <br /> FIELD OF VIEW. MAGNETIC 5' 4081-9009 733-912 20 RED BLK BLK LLD N/A 1 TO MR-101 RELAY COIL 40058 POINT I/O <br /> 96"MAX(ADA,IBC,NFPA) (TOOL REQUIRED) PLUG,ACCESSIBLE <br /> ON _ ?i <br /> 90"MIN 2286mm MIN DOOR (127mm) PLUG,ACCESSIBLE ONLY STROBE NC. (ACROSS CONTACTS) 4005',4090-90011DNET LAM Q <br /> (2440mm MAX) ( ) HOLDER ENTIRE LENS: CIRCUIT TO NEXT 24 PT.I/0(ACROSS CONTACTS 4605-7401,4100 SERIES a <br /> ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR SIDE WALL 80"(2032mm)A.F.E.MINIMUM FROM REAR OF HOUSING; ��; DEVICE OR 4081-9010 733-973 1K BRN BLK RED GLD N/A 1 O <br /> (OTHER MOUNTING HEIGHTS SHALL BE r FINISHED FACTORY SETTING IS 15cd AUDIO <br /> TOTOP OF LENS 96"(2044mm)0.F.F MAXIMUM 10K EOL CURRENT LIMITED N.O.INIT. <br /> PERMITTED BY THE AN PROVIDING IT MEETS THE ® DOOR WALL FORCEILINGS<86'(2180mm)A.F.F.: CIRCUIT (-) (-) (IN SERIES WITH CONTACT) 4090-90011DNET LAM O <br /> MI(ADA IBC,NFPA) SOUND LEVEL OUTPUT REQUIRED.) WIDTH <-6"(150mm)FROM CEILING 4081-9011 733-974 100 BRN BLK BRN GLD N/A 1/2 ANNUNCIATOR(N2) 4006,4008,4010 U ~ <br /> (2032mm MIN) FIRE MANUAL PULL LESS 3' TERMINATION VIEW:DEVICE MOUNTING PLATE U <br /> STATION MOUNTING OPTION"C" CLASS B WIRING 4081-9012 733-985 22K RED RED ORG GILD N/A 1/2 SPEAKER CIRCUIT 4003 U W Ld <br /> ABOVE FINISHED FLOOR PHONE (76mm) 4081-9013 734-086 4.99K YEL WHT WHT BRA BRA 1/2 = 00 Of � <br /> TO BOTTOM OF LENS JACK WIRING NOTES N.C.INITIATING(SECURITY W I <br /> 4081-9014 734-092 2AK RED YEL RED GILD N/A 1/2 4090-90011DNET LAM z U — — O <br /> MONITORING EOLR) p V) W CC <br /> MOUNTING OPTIONS 1. MAINTAIN CORRECT POLARITY ON CURRENT LIMITEDN.O.INIT. �." Q 0_ Q <br /> NOTE:REFER TO THE PROPER DEVICE 48"MAX(ADA)(R19mm) OPTION DESCRIPTION NOTE TERMINAL CONNECTIONS. 4081-9015 734-093 1.SK BRN GRIN RED GILD N/A 112 4090-9001 IDNET LAM 2 F F <br /> INSTALLATION INSTRUCTIONS (SECURITY MONITORING EOLR) C1. <br /> _ U <br /> 48"MAX(NFPA,ADA)(1219mm MAX) 4"p02mm)SQUARE BOX,1-1/2'(38mm)DEEP,WITH 2. ALWAYS CUT CONDUCTORSRND SECURE g081-9016 734-149 t5OKBRNORG GRN YEL GLD N/A 1/2 — Y Y <br /> FOR BACKBOX MOUNTING HEIGHT. A BY OTHERS } <br /> 42"MIN(NFPA) MIN) 1-12"(38mm)EXTENSION RING-FLUSH MOUNTING UNDERTERMINALS.NEVER LOOP WIRES 4081-9017 734-171 WHT RED GLD N/A 1 } 2 U UMEASUREMENTS SHOWN ARE UNDERTERMINALS. U O_ W WFINISHED SIMPLEX 2975-9145 SURFACE MOUNT BOX WITH SIMPLEX 4081-9018 734-168 BLK ORG GLD N/A 1 70VRM5 CONSTANT SUPV.NAC 4100-1260 q Qp p Q <br /> FLOOR TO TOP OF PULL HANDLE B4905-9903 ADAPTER PLATE ORDERED SEPARATELY 3, ANY WIRE SPLICES TO BE MADE BY LISTED 378-090 RED RED GLD N/A 1/2 SECURITY MONITORING(EOLR) 4100,41000 z 2 <br /> 4"(102mm)SQUARE BOX,1-1/2'(38mm)DEEP,WITH SIMPLEX ADAPTER AND AHI APPROVED METHODS. 378-046 BLU RED GLD N/A 112 N.O.SECURITYMON.(SERIES) 4100,41000 w QC1-1/2"(38mm)EXTENSION RING-SURFACE MOUNTING SKIRT REQUIRED 378-069 RED ORG GILD I N/A 1 112 1 N.C.SECURITY MON.(SHUNT) 4100,41000 m = _ d <br /> 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0003 FROM HTTP://WW.SIMPLEX-FIRE.COM 'USE WITH RETROFIT OR HIGH CURRENT MODULE d d <br /> } } I I I <br /> m CO m wOf <br /> O O 00 00 00 <br /> N N <br /> J J 2 2 <br /> J J I, r 04 <br /> N N N N 04 <br /> A CD <br /> 't 00 <br /> O A co n <br /> z <br /> DRAWINGS REVIEWED�ff ] <br /> Eric Beck,CET INICET#148077 •i <br /> Fire Alarm Systems,Level III <br /> M� <br /> a <br /> O <br /> N� <br /> W <br /> w <br /> E- <br /> z <br /> w <br /> a <br /> Q <br /> w <br /> F <br /> F <br /> w w <br /> EI w <br /> w <br /> x Z z <br /> a by <br /> Q r <br /> W H 0O <br /> w <br /> w Q a � � <br /> a APPROVED BY: <br /> z <br /> C.A.M. <br /> z <br /> DRAWN BY: <br /> 0 <br /> � J.D.B. <br /> z <br /> 0 DATE: <br /> w 9/12/96 <br /> w <br /> sin NUI®6R/PRO7ECT NWIBBR <br /> 458-400892 <br /> SHEET NUMBER: <br /> FA—DET-03 <br /> a <br />
The URL can be used to link to this page
Your browser does not support the video tag.