Laserfiche WebLink
LEGEND: <br /> OS PHOTO ELECTRIC SMOKE DETECTOR <br /> ❑E MANUAL STATION, DOUBLE ACTING <br /> ® STROBE ALARM CEILING MOUNTED <br /> HE11 AUDIBLE/VISUAL ALARM <br /> FACP FIRE ALARM PANEL <br /> 0 ADT PANEL <br /> TELG CELLULAR COMMUNICATOR <br /> FD M MINI INPUT MODULE <br /> GENERAL_ NOTES <br /> 45-218 IS MONITORED BY 45-214 BUILDING FACP. <br /> 2 <br /> 1 SIRE ALARM C9NTROL IAA 1) BUI ING FACP< <br /> O 2 <br /> LwnQITELG FACP REFERENCE DRWAWINGS <br /> HEAT WOMEN RE TROOP' CELL TRBL.MONITOR <br /> ZONE 68, L1:08 4 F MAN PULL DR Wi ZONE#: 10,u:ro SMK® FACP 45-214-1E60 POWER AND FIRE ALARM PLAN <br /> EOL ZONE#: 07, L1:07 ZONE#: 01, L1:01 VIEW <br /> 15cd <br /> /5 S 45-214—E506 FIRE ALARM DETAILS <br /> 3 CONSTRUCTION NOTES <br /> s� l� <br /> WH <br /> 75cd SMK®OFFICE CENTERF SMK®OFFICE N 75cd <br /> F _ sMK®oFFIGF s 1/3 ZONE#: 02, L1:02 ZONE#: 03, L1:03 7 d /1 THIS FIRE ALARM DESIGN IS INTENDED TO BE A <br /> ZONE#: 05, 1:05 6 PRELIMINARY DESIGN TO DIRECT A NICET CERTIFIED <br /> S �L ' E WP DESIGNER TO COMPLETE FINAL FIRE ALARM DESIGN IN <br /> HEAT 0 09, LEOTIRoO S 4 4 g ACCORDANCE WITH ALL APPLICABLE LAWS AND CODES. <br /> O APPLICATION FOR FIRE ALARM PERMIT USING FINAL <br /> H STAMPED DRAWINGS IS REQUIRED. <br /> 15 REMOVE OLD FACP, FOCUS PANEL, AND ASSOCIATED <br /> 0 /4 HARDWARE. PROVIDE AND INSTALL NEW DIGITAL <br /> V4� \T ADDRESSABLE BUILDING FACP. PROVIDE PHENOLIC LABEL <br /> I I ON PANEL THAT READS: <br /> 0 1 <br /> i 4 F MAN PULL DR E1 4 F MAN PULL DR E2 "45-214 FIRE ALARM CONTROL PANEL <br /> ZONE#:O6, L1:06 ZONE#: 04, L1:04 <br /> EVi—FA-45-214 <br /> O O 120VAC FED FROM PANEL 'B'/26a" <br /> PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDING <br /> FACP. SEE SHEET E506 FOR INSTALLATION DETAILS. <br /> INSTALL NEW SMOKE DETECTOR ABOVE FACP. <br /> ®REPLACE EXISTING FIRE ALARM DEVICE WITH NEW <br /> COMPATIBLE DEVICE. REUSE CONDUIT AND WIRE WHERE <br /> POSSIBLE. (TYP. 3 SMOKES, 3 HEATS, 3 MANUAL PULL <br /> STATIONS) <br /> FILL OUT AND RETURN ATTACHED BUILDING FACP <br /> POINTLIST TO ENGINEER A MINIMUM OF 3 WEEKS PRIOR <br /> TO FINAL ACCEPTANCE TESTING. <br /> ©PROVIDE NEW HORN/STROBE. NICET DESIGNER TO <br /> PLAN VIEW N DETERMINE FINAL LOCATION AND QUANTITY AS REQUIRED <br /> SCALE: 1/4"=1'-0" BY <br /> SEE DRAWING 45-301-1E60 FOR 2 ADDITIONAL FIRE <br /> ALARM POINTS. <br /> Timothy C.Eastman-25w* <br /> NICET C��an 1� <br /> er�ys Level IV 4' 2' 0 2' 4' 8' <br /> �rh Ication Expires:March 01,2025 <br /> PERMIT SUBMITTAL SCALE: 1/4"-1'-0" <br /> 03.03.24 PO BOX 1138 <br /> SEATp AUBURN,WA 98071 <br /> IRONICS 2S3-939-6060 <br /> FIRE PROTECTION SERMCES JOB NO.of BwG xo. <br /> 9132326 9132326-1E260 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> - FIRE ALARM PANEL REPLACEMENT SEA 03.03.24 THIS DESIGN AND/OR CHECKED FIRE ALARM PLAN 9132326 03.03.24 0 <br /> SPECIFICATION IS APPROVED N IN TITLE SHEET N <br /> -BOE//VG® APPROVED BY DEPT DATE <br /> NECKED 1 E260 3 <br /> APPROVED BUILDING 45-214 JOB NO� DDM 45-2,4_,E26o zo <br /> APPROVED ELECTRICAL MASTER EVERETT, WA DWI No. 45-214-1E260 <br />