My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-313 2024-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-313
>
3003 W CASINO RD BLDG 45-313 2024-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2024 9:37:32 AM
Creation date
11/6/2024 9:57:46 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-313
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Step 6: Elevators PASS FAIL N/A <br />1. Elevator Technician - Elevator technician must be on site for the following test to ❑ ❑ ❑ <br />take place. <br />2. FACP - Actuation from the elevator hoistway, elevator machine room, elevator ❑ ❑ ❑ <br />machinery space, elevator control space, or elevator control room smoke <br />detectors, or other automatic fire detection shall cause a separate and distinct <br />visible annunciation at the building FACP and remote annunciators to alert fire <br />fighters that the elevators are no longer safe to use. <br />3. Recall - Test detector(s) located at elevator lobby that will initiate elevator recall: ❑ ❑ ❑ <br />(Elevator lobby detectors must be within 21 feet of each elevator door.) <br />• Verify recall to a primary floor <br />• Verify recall to alternate floor <br />• Verify illumination of "Fire Hat" <br />4. Machine Room Detector - Test detector(s) located in shaft & elevator machine ❑ ❑ ❑ <br />room: <br />• Verify recall to designated floor <br />• Verify flashing illumination of "Fire Hat" <br />5. Heat Detectors - Heat Detectors installed in a shaft or machine room and used for ❑ ❑ ❑ <br />shunt trip (shut down elevator power) activation shall be located within 2 feet of <br />each sprinkler head and have both a lower temperature rating and a higher <br />sensitivity as compared to the sprinkler. <br />Step 7: Initiation Devices PASS FAIL N/A <br />1. FACP - Test individual devices to ensure proper operations and annunciation at the ❑ ❑ ❑ <br />panel with the correct device location. <br />Smoke Detectors: <br />2. Sample Test - The fire inspector will select a sample of Smoke Detectors at ❑ ❑ ❑ <br />random to be tested by using smoke or a listed aerosol. (minimum of one per floor <br />and no less than 10% of the devises shall be tested) <br />3. Trouble - The fire inspector will select a minimum of one smoke detector at <br />❑ <br />❑ <br />❑ <br />random to be disconnected to verify a trouble signal is received at the FACP. <br />4. Addressable - All smoke detectors are addressable models. <br />❑ <br />❑ <br />❑ <br />5. Wall Mount - Wall -mounted smoke detectors must be installed between 4 and 12 <br />❑ <br />❑ <br />❑ <br />inches from the ceiling measured to the nearest edge of the detector. <br />Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 <br />4.13.2020 <br />1 Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.