Specifications <br /> Main Board—(continued) <br /> There are also LEDs to indicate when audible circuits are The main board contains a universal serial bus (USB) <br /> 'active' or 'silenced.' The main board supports four (4) connector that supports connection for system <br /> system-control buttons, including: Acknowledge; Alarm configuration and module firmware upload,via the <br /> Silence; Unsilence, and Reset. custom-configuration tool. <br /> The system offers an off-normal warning feature, Model FC901 can be configured using the custom- <br /> alerting users when active devices are not ready for configuration tool or manually from the alphanumeric <br /> reset. These active devices may include manual stations keypad on the main board. An auto-configuration <br /> that have not been reset; smoke detectors with smoke feature creates a basic system configuration of all <br /> remaining in the optical chamber, etc. connected devices to accelerate initial system <br /> Additionally, the main board supports an commissioning. <br /> alphanumeric keypad, as well as navigation keys, <br /> which are used for scrolling maintenance functions <br /> and system configuration. 50-Point Addressable System Enclosure <br /> The main board supports connection for up to 50 The Model FH901-U3 I R3 enclosure for the 50-point <br /> addressable devices, via one (1) 'Class A', or two (2) addressable fire system, Model FC901, supports all <br /> 'Class B' circuits. The loop supports all C-NET devices, system modules. The enclosure also supports up to <br /> including the Cerberus PRO intelligent and Model 'H'- 12AH batteries. <br /> series devices. The main board also supports one (1) Note: For systems requiring larger than 12AH <br /> 'Class A'or two (2)'Class B'NACs. batteries, use a OUL Listed battery box. <br /> Each NAC supports a maximum 2.5 Amps — with 2.5 The Model FH901-U3 I R3 enclosure for the 50-point <br /> Amps, max, allowed between the NACs. Each NAC can panel is comprised of a dual-mounting setup that <br /> be set to a synchronized strobe, for horn-strobe allows the main board to be partially mounted in a <br /> devices, or for audible devices. Audible devices can be lower-to-upper position. When temporarily installed <br /> set for: in the lower position, technicians are allowed more <br /> • 'STEADY' space to install field wiring at the time of system set- <br /> • 'ANSITemporal 3'I'ANSITemporal4' up. When field-wiring installation is complete, the <br /> • 'March Time 30 1 60 1 120 Codes' main board shall be moved to the upper position for <br /> The main board supports four (4) 'Form C'relays for standard mounting prior to applying power to the <br /> Alarm, Trouble, Supervisory and User Programmable system. <br /> events. Each relay is rated at 2 Amps at 30VDC Additionally, the enclosure supports an optional <br /> maximum, resistive. The main board supports two (2) battery bracket (Model FHA901-U1) that can be used <br /> auxiliary 24VDC connections. Upon system reset, one to secure batteries up to 12AH. Model FHA901-U1 is <br /> (1) connection interrupts the power for five seconds required to comply with seismic certification, <br /> for use with (4) four-wire conventional detectors. Each pursuant to ASC I SEI 7-05, Section 13.2.2. <br /> auxiliary-power output is 24VDC, nominal —rated at A flush-mount trim kit (Model FHA902-Ul I R1) is <br /> 0.75 Amps. also available for use when flush mounting <br /> The main board contains a built-in DACT that provides Model FH901-U3 I R3. <br /> communication between Model FC901 and with the <br /> central or remote monitoring station. The built-in DACT <br /> supports two (2) separate programmable accounts, as 50-Point Power Supply <br /> well as two (2) connections to the public-switched The Model FCM901-U3 main board also supports <br /> telephone network. The connections support RJ31 X connection to the system power supply. The 6.5A <br /> male connectors. (170-Watt) power supply (Model FP2016-U1) <br /> (For compatibility with each Model FC901 FACP, see incorporates a 4.OA, non-resettable slow-blow fuse <br /> the Central Station Receiver Compatibility Table on on the primary input, and includes a built-in AC-line <br /> the last page of this data-sheet document.) filter for surge and noise suppression. <br /> The main board contains a battery-charging circuit, Model FP2016-U1 mounts in a standard Siemens — <br /> providing connection to lead-acid batteries rated at Fire Safety enclosure, and there are no serviceable <br /> 24VDC, nominal. The main board can charge up to Siemens — Fire Safety parts to be maintained. <br /> 18 AH batteries. <br /> SIEMENS Industry, Inc. Cerberus° PRO <br /> Building Technologies Division <br />