My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-715 2024-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-715
>
3003 W CASINO RD BLDG 45-715 2024-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2024 9:58:52 AM
Creation date
11/6/2024 11:43:05 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-715
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications - (continued) <br /> — Optional Accessories— <br /> Leased-Line/ City-Tie Module LED Annunciator Driver: 32 Outputs 116 Inputs <br /> The Model FC901 FACP has the capability of operating Model FT2007-Ul serves as the main component <br /> an optional leased-line, city-tie module (Model for allowing custom graphic annunciators to <br /> FCI2020-Ul) that provides a local-energy output for operate on Model FC901 FACPs. There are 16 <br /> municipal call-box connection. inputs on each Model FT2007-Ul to accommodate <br /> A wiring harness, Model FCA901-U1, is required for user-defined system commands, which include: <br /> use, and must be ordered separately. The leased-line, Reset; Silence/Unsilence; Acknowledge, and Lamp <br /> city-tie module is installed on the back of the main Test. Inputs can also be programmed as "Generic", <br /> board of the Model FC901 FRCP, and field wiring is which allows additional flexibility for customized <br /> connected to the main board. functionality. <br /> 50-Point Remote Annunciator Shipments of each Model FT2007-Ul driver include <br /> The fire-system displays (FSD901-U3 I R3) are remote two (2) PC boards [PCBs]; one (1) built-in RS-485 <br /> LED I LCD units that show the existing status of the interface, and one (1) LED driver. Additionally, one <br /> Model FC901 FACP. The Model FSD901-U3 I R3 optional (1) ribbon cable is packaged, allowing connectivity <br /> display supports the following LEDs for system-status between the two (2) PCBs. <br /> conditions: <br /> • Power Tabular Annunciator Drivers: <br /> • Alarm 16 Zones 132 Zones <br /> • Trouble The Tabular Annunciators allow system events sent <br /> • Supervisory from Cerberus PRO 50-point addressable panels to <br /> • Ground-Fault be displayed remotely in real-time. <br /> There are also LEDs to indicate when audible circuits The Model FT2008 series of tabular annunciators <br /> are 'active' or 'silenced.' The main board supports four has 16 zones and the Model FT2009 series uses up <br /> (4) system-control buttons, including: Acknowledge; to 32 zones. Additionally, no more than two (2) <br /> Alarm Silence; Unsilence, and Reset. light-emitting diodes (LEDs) can be used per zone. <br /> For Model FSD901-U3 I R3, a LED will illuminate for any A built-in RS-485 communication bus controls the <br /> given Alarm, Supervisory and Trouble Cerberus PRO- <br /> system event. A 3.5-inch (8.9 centimeters) by 1.5" operation and supervision of the 16-zone and 32- <br /> (3.8 centimeters) LCD screen will give details of the zone Tabular Annunciators, which are available in <br /> event in alphanumeric form. The display screen can be black or red. <br /> scrolled to reveal additional events. Optional remote- <br /> system-control capabilities are also available. Temperature and Humidity Range <br /> The Remote Peripheral Module (FCA2018-U1) provides a Model FC901 is oUL 864 91" Edition Listed for <br /> means of connecting a Cerberus PRO 50-point indoor dry locations within a temperature range of <br /> addressable panel to a parallel printer for creating a hard 120 +I- 3°F (49 +I- 2°C) to 32 +I- 3°F (0 +I- 2°C) and a <br /> copy of system-status events. <br /> relative humidity of 93 +I- 2% at a temperature of <br /> This supervised, intelligent module contains built-in 90 +I-3°F (32 +I-20C). <br /> transient protection and plain-decimal addressing. <br /> When Model PAL-1 is used with the remote peripheral <br /> module, Model FCA2018-Ul supervises the printer for Related Documentation <br /> ON, OFF Line I POWER ON I PAPER OUT I PAPER JAM, and Product Data Sheet Number <br /> wiring-fault conditions, as required by oUL for NFPA 72 170-Watt power supply 9806 <br /> proprietary systems. Leased-Line I City-Tie Module 9810 <br /> The following are the dimensions based upon Remote Peripheral Module 9811 <br /> connection to a one-height-unit enclosure (1HU) for <br /> Model FC901: 50 Point Remote Annunciator 9817 <br /> LED Annunciator Driver, FT2007-U1 9824 <br /> Approximate size: 16.5"(41.9 cm.) [H]; 16-Zone (FT2008-U1)132-Zone <br /> 18.13"(46.1 cm.) [W]; 9825 <br /> 5.11""(13 cm.) [p] (FT2009-U1)Tabular Annunciators <br /> The weight (without operating unit or batteries) is <br /> approximately 9 pounds [4082 g]. <br /> SIEMENS Industry, Inc. Cerberus' PRO <br /> Building Technologies Division <br />
The URL can be used to link to this page
Your browser does not support the video tag.