Laserfiche WebLink
SIEMENS <br /> Devices Initiating Devices F <br /> Intelligent . Modules <br /> • • <br /> Wiwi M Product Overview <br /> ❑ Siemens ISOtechnologym The Siemens - Fire Safety XTRI-series Intelligent Interface Modules are designed to <br /> Provides "True Class -X"operation provide the means of interfacing direct shorting devices to the fire-alarm control <br /> to NFPA 72 SLC field wiring panel (FRCP) SLC. All modules take up one(1) address on the loop. <br /> requirements <br /> Each XTRI-series interface module provides the "built-in" ISOtechnology feature - <br /> Supports 252 ISOtechnology ready intelligent dual isolation meeting NFPA 72 Class X(Style 7)wiring requirements. Up <br /> devices per loop,and in mixed mode up to 30 devices between isolated to 252 isolators per loop and up to 30 devices between isolators (wired in polarity- <br /> devices insensitive mode). Additionally,the devices between isolators can either be'H'-series <br /> or the more contemporary'X'-series detection devices. <br /> ❑ Dual input on Model XTRI-D, via <br /> a single address <br /> ❑ Integral single-pole, double-throw The Siemens - Fire Safety XTRI-series Intelligent Interface Modules are available in <br /> (SPDT) relay on Model XTRI-R: <br /> - Up to 4 Amps. three (3) individual types: <br /> > One(1) Dual-Input: XTRI-D <br /> ❑ Low current draw > Two(2)Single-Inputs: XTRI-R (with relay) I XTRI-S <br /> ❑ Polarity insensitive (in non-isolation — The single-in put versions are each designed to monitora normally <br /> mode) via SurewireTm technology: open (N.0) or(N.C) normally closed dry contact <br /> - Modern technology supports XTRI-D I XTRI-R I XTRI-S incorporates ISOtechnology—the configurable, built-in dual <br /> comprehensive system and isolator function. Additionally, an XTRI-series interface module supports NFPA 72 <br /> interface communication <br /> Class X (Style 7) survivability requirements for shorts while providing reliable alarm <br /> ❑ Multi-color light-emitting diode(LED) communication to the Siemens FRCP. The isolation feature found on the XTRI-series <br /> indicates system status: Intelligent Interface Modules gives information as to the location of the fault.When <br /> - GREENIAMBERIRED a short occurs, the panel can identify the fault automatically, and the module <br /> ❑ Mounts in a 4-inch (10.2 cm.)square, 2- recognizes the short location (in front of the device or behind the device). <br /> 1/4"(5.7 cm.)deep single-gang or Overall, the built-in isolators improve the diagnostics and location of the problem, <br /> double-gang back box including a short. <br /> ❑ Non-obstructive front-end access to The modules are configurable by a Siemens compatible FACP (or panels) in an <br /> programming port and wiring terminals isolator(polarity sensitive)or non-isolator(polarity insensitive)mode. When a XTRI- <br /> ❑ Device Programmer I Test Unit programs series interface module is configured as an isolator,that module has the capacity of <br /> and verifies address, as well as tests functioning as both an in/out device, as well as an isolator. <br /> device functionality <br /> ❑ Restriction of Hazardous Substances Advanced troubleshooting is provided by compatible <br /> (RoHS) compliant panels by identifying when a XTRI-series interface pf„r,� <br /> p module is configured as an isolator, but is wired " <br /> ❑ UL864 I UL2572 I UL2017 Listed;CAN/ULC- incorrectly in a polarity-insensitive mode. <br /> 5527 &CAN/ULC-5576 Listed , <br /> File 524304, Vol.3 ; <br /> Each Model XTRI-series device has a multi-color LED <br /> that flashes when GREEN operating in Normal mode; <br /> AMBER if the unit is in a 'Trouble' condition, and RED <br /> to indicate a change of status. <br /> Model XTRI-S <br /> This single-input interface module can only monitor <br /> and report the status of a N.O.or N.C.contact. <br /> KF I Intelligent Device <br /> Interface Module <br /> Siemens Data Sheet 6167 <br /> Smart Infrastructure - Building Products usa.siemens.com/fire <br />