My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10829 19TH AVE SE STE 1A 2024-12-04
>
Address Records
>
19TH AVE SE
>
10829
>
10829 19TH AVE SE STE 1A 2024-12-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2024 1:37:50 PM
Creation date
11/6/2024 11:57:18 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10829
Unit
STE 1A
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER i PA-4000 <br /> The Symbol of Protection Fire Alarm Control Panel <br /> SLC Loop Accessories <br /> The control panel may be connected with up to 4,064 addressable devices or modules in any combination.The SLC is not restricted by any special <br /> wire requirements and may be wired with any wire that complies with the NEC. <br /> SLC Loop Devices <br /> Device Description <br /> PAD Series-PD Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.1 to 3.5%/foot.UL 268 7th Edition. <br /> Combination Analog Photoelectric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.1 to 3.5 Moot <br /> PAD Series-PHD obscuration and a fixed temperature range of 135'to 185'F heat detector.Smoke detection compliant with UL 268 7th <br /> Edition. <br /> PAD Series-PCD Combination Photoelectric Smoke/Carbon Monoxide Detector.Smoke detection compliant with UL 268 7th Edition.Carbon <br /> Monoxide detection compliant with UL 2075. <br /> Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector.Smoke detection compliant with UL 268 7th Edition.Heat <br /> PAD200-PCHD detection with a fixed temperature range of 135'to 185'F and UL 521 7th Edition compliant.Carbon Monoxide detection <br /> compliant with UL 2075. <br /> PAD Series-HD Analog Fixed Temperature(135'- 185°F)or Rate-of-Rise Heat Detector(software selectable). <br /> PAD Series-DUCTR Addressable Duct Smoke Detector with Form C Relay rate at IOAmps @ 250/120VAC or 8 Amps at 30VDC. <br /> PAD Series-DUCT Addressable Duct Smoke Detector. <br /> PAD100-6DB 6"round base that is mountable to an electrical box and wired for connection to the PAD 100/200 devices. <br /> PAD 100-4DB 4"round base that may be mounted to an electrical box and wired for connection to the PAD 100/200 devices. <br /> PAD 100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop and used for <br /> connection to the PAD 100/200 devices. <br /> PAD 100-RB Addressable Relay Base that contains one relay controlled by the SLC.Relay at rated at 2 amps at 30 VDC or 0.5A at <br /> 125VAC.For PAD 100/200 devices only. <br /> PAD 100-SB Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local,group,and/ <br /> or all call.For PAD 100/200 devices only. <br /> PAD Series-CD Addressable CO gas detector. <br /> PAD200-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. <br /> PAD300-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure or pendant mount applications. <br /> Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration <br /> PAD100-LFSB of local,group,and/or all call.The LFSB complies with the Low Frequency Signal Requirements(520 Hz)and used for <br /> connection to the PAD 100/200 devices. <br /> PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W and <br /> used for connection with the PAD 100/200 devices. <br /> PAD300-6DB 6"round base which is mountable to an electrical box and wired for connection to the PAD300 devices. <br /> PAD300-4DB 4"round base which is mountable to an electrical box and wired for connection to the to the PAD300 devices. <br /> PAD300-113 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop.Used for <br /> connection to the PAD300 devices. <br /> PAD300-RB Addressable Relay Base that contains one relay controlled by the SLC.The Relay is rated 2 amps at 30 VDC or 0.5A at <br /> 125VAC and used for connection to the PAD300 devices <br /> PAD300-SB Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local,group,and/or <br /> all call;and used for connection to the PAD300 devices. <br /> Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration <br /> PAD300-LFSB of local,group,and/or all call.The LFSB complies with the Low Frequency Signal Requirements(520 Hz)and used for a <br /> connection to the PAD300 devices. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830102-REV J 5/23 PAGE 2 OF 5 <br />