INSTALLATION AND MAINTENANCE INSTRUCTIONS SILENT W <br /> .. 13 KNIGHT <br /> EVERETT EYERETT <br /> C1 0 <br /> Everett Fire Dept. Permit Review by Honeywell <br /> Status:Approved <br /> Reviewed By: KBrown 7550 Meridian Circle,Maple Grove,MN 55369-4927 <br /> 06/24/2024 12:30:50 763-493-6455;800-328-0103 Fax:763-493-6475 <br /> SK-Monitor Module PM http://www.silentknight.com <br /> SPECIFICATIONS <br /> Normal Operating Voltage: 15 to 32 VDC <br /> Maximum Current Draw: 5.0 mA(LED on) <br /> Average Operating Current: 375pA(group poll),350 pA(direct poll),600 pAmps(communication,IDC shorted) <br /> EOL Resistance: 47K Ohms <br /> Max.IDC wiring resistance: 1,500 Ohms <br /> Maximum IDC Voltage: 11 Volts <br /> Maximum IDC Current: 450pA <br /> Temperature Range: 32°F to 120°F(0°C to 49°C) <br /> Humidity: 10% to 93% Non-condensing <br /> Dimensions: 41/2"H x 4"W x 11/4"D (Mounts to a 4"square by 21/s"deep box.) <br /> Accessories: SMB500 Electrical Box <br /> BEFORE INSTALLING FIGURE 2.MODULE MOUNTING: <br /> This information is included as a quick reference installation guide. Refer to NOTE:For UL Listed security installations,the SK-Monitor must be mounted <br /> the control panel installation manual for detailed system information. If the within the control panel enclosure. <br /> modules will be installed in an existing operational system,inform the opera- <br /> tor and local authority that the system will be temporarily out of service.Dis- <br /> connect power to the control panel before installing the modules. e <br /> NOTICE:This manual should be left with the owner/user of this equipment. m® <br /> GENERAL DESCRIPTION '� <br /> The SK-Monitor Module is intended for use in intelligent, two-wire systems, <br /> where the individual address of each module is selected using the built-in <br /> rotary switches.It provides either a Class A or Class B fault tolerant initiating <br /> device circuit(IDC) for normally open contact fire alarm and supervisory de- <br /> vices,or either normally open or normally closed security devices.The mod- \ <br /> ule has a panel controlled LED indicator. <br /> ISOLATED <br /> COMPATIBILITY REQUIREMENTS <br /> � QUADRANT <br /> To ensure proper operation, this module shall be connected to a compatible <br /> Silent Knight system control panel(list available from Silent Knight). <br /> FIGURE 1.CONTROLS AND INDICATORS: <br /> 00 <br /> ro e o <br /> T91 <br /> T90 T9 C1066-00 <br /> WIRING <br /> T9 T2 NOTE: All wiring must conform to applicable local codes, ordinances, and <br /> regulations.This module is intended for power limited wiring only. <br /> TS T3 <br /> 1. Install module wiring in accordance with the job drawings and appropri- <br /> T7 567 8910 587 89 T4 ate wiring diagrams. <br /> T6 41° \ln 4/1�,11 T5 2. Set the address on the module per job drawings. <br /> 2 3 2� 3. Secure module to electrical box(supplied by installer),as shown in Figure 2. <br /> 1015 10 <br /> o TENS 9 ON <br /> o <br /> Qoo D Sr <br /> C1067-00 <br /> MOUNTING <br /> The SK-Monitor mounts directly to 4-inch square electrical boxes (see Figure <br /> 2).The box must have a minimum depth of 21/8 inches.Surface mounted elec- <br /> trical boxes(SMB500)are available from Silent Knight. <br /> SK-460-013 1 I56-3442-000 <br />