Laserfiche WebLink
0 MAME° <br /> Gross Cooling Capacities <br /> Table 5. Gross cooling capacities-6 tons <br /> Entering Wet Bulb Temp(°F) Entering Wet Bulb Temp(°F) Entering Wet Bulb Temp(°F) <br /> CFM Ent D)B 61 67 73 61 67 73 61 67 73 <br /> MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC <br /> Ambient Temperature 85°F Ambient Temperature 95°F Ambient Temperature 105°F <br /> 75 67.9 54.2 77.6 43.2 85.6 29.1 63.8 51.9 73.0 40.9 80.2 28.6 59.4 49.6 68.1 38.5 74.1 26.5 <br /> 1860 80 67.7 63.3 77.5 53.0 85.9 40.7 63.7 60.9 73.0 50.7 80.6 38.3 59.3 58.5 68.1 48.3 74.8 35.8 <br /> 85 69.3 69.3 77.3 62.5 86.1 50.9 66.1 66.1 72.9 60.5 81.0 48.4 62.5 62.5 68.0 57.9 75.2 45.9 <br /> 90 77.1 71.7 77.1 71.7 86.2 60.6 70.3 70.3 72.7 69.4 81.0 58.3 66.7 66.7 67.9 66.9 75.3 55.8 <br /> 75 70.3 59.0 80.0 46.2 87.3 30.8 65.9 56.4 75.2 43.7 81.5 28.7 61.3 52.4 70.0 41.2 75.1 27.2 <br /> 2160 80 69.9 69.0 79.9 57.4 87.7 42.9 65.7 65.7 75.2 55.0 82.1 40.6 61.6 61.6 70.0 52.6 76.0 38.1 <br /> 85 73.4 73.4 79.7 68.0 88.0 54.5 69.9 69.9 75.0 63.6 82.5 52.1 66.1 66.1 69.8 63.1 76.3 49.5 <br /> 90 77.9 77.9 79.3 78.4 88.1 66.0 74.3 74.3 74.6 74.6 82.6 63.6 70.3 70.3 70.4 70.4 76.5 61.0 <br /> 75 71.7 61.4 81.6 48.2 88.3 31.6 67.2 57.2 76.6 45.8 82.6 29.3 62.3 57.0 71.3 43.3 76.1 27.9 <br /> 2400 80 71.3 71.3 81.5 60.7 88.8 44.8 67.7 67.7 76.5 59.3 83.1 42.4 63.9 63.9 71.2 55.9 76.9 39.9 <br /> 85 76.1 76.1 81.0 72.3 89.1 57.4 72.4 72.4 76.1 69.8 83.4 55.0 68.4 68.4 70.7 67.1 76.9 52.3 <br /> 90 80.8 80.8 80.9 80.9 89.2 70.1 76.9 76.9 77.0 77.0 83.5 67.7 72.5 72.5 72.6 72.6 77.2 63.1 <br /> 75 72.7 65.3 82.9 50.3 89.5 32.3 68.0 62.8 77.8 47.9 83.4 30.5 63.1 60.1 72.3 45.3 77.0 26.1 <br /> 2640 80 73.5 73.5 82.7 64.0 89.9 46.5 69.8 69.8 77.6 61.6 84.1 44.0 65.8 65.8 72.1 59.0 77.6 41.3 <br /> 85 78.5 78.5 82.0 76.2 89.9 60.3 74.6 74.6 76.9 73.7 84.0 57.8 70.4 70.4 71.4 71.4 77.5 55.1 <br /> 90 83.2 83.2 83.3 83.3 90.1 73.3 79.0 79.0 79.1 79.1 84.2 67.9 74.2 74.2 74.3 74.3 77.3 67.9 <br /> 75 73.5 68.4 84.0 52.3 90.5 32.9 68.8 65.8 78.7 49.9 84.3 30.8 63.7 63.1 73.0 47.3 77.7 28.9 <br /> 80 75.5 75.5 83.7 67.2 90.7 48.1 71.7 71.7 78.5 64.2 84.6 45.5 67.5 67.5 72.8 59.5 78.3 43.0 <br /> 2880 <br /> 85 80.6 80.6 82.7 80.1 90.6 63.1 76.5 76.5 77.5 77.5 84.5 60.6 72.0 72.0 72.1 72.1 78.2 58.0 <br /> 90 85.1 85.1 85.2 85.2 90.6 77.1 80.7 80.7 80.7 80.7 84.3 74.4 75.4 75.4 75.5 75.5 77.6 71.5 <br /> Ambient Temperature 115°F Ambient Temperature 125°F <br /> 75 54.7 46.9 62.7 36.0 67.7 23.3 49.6 42.5 56.9 33.2 60.9 18.6 <br /> 1860 80 54.7 54.7 62.8 45.8 68.3 33.1 50.6 50.6 57.0 43.0 61.3 30.3 <br /> 85 58.7 58.7 62.8 53.6 68.7 43.1 54.4 54.4 56.9 52.3 61.5 40.1 <br /> 90 62.6 62.6 62.7 62.7 68.9 53.1 57.9 57.9 58.0 58.0 61.6 50.1 <br /> 75 56.2 51.0 64.4 38.6 68.9 24.1 50.8 48.1 58.3 35.8 61.8 21.0 <br /> 2160 80 57.7 57.7 64.4 50.0 69.4 35.3 53.3 53.3 58.3 47.1 62.4 32.4 <br /> 85 61.9 61.9 64.2 60.3 69.5 46.6 57.1 57.1 58.0 57.3 62.4 43.8 <br /> 90 65.7 65.7 65.8 65.8 69.6 57.3 60.1 60.1 60.2 60.2 62.4 54.6 <br /> 75 57.1 54.2 65.5 40.6 69.8 24.4 51.6 51.3 59.1 37.7 62.2 22.4 <br /> 2400 80 59.7 59.7 65.4 53.2 70.2 36.9 55.0 55.0 59.1 48.8 63.0 34.0 <br /> 85 63.9 63.9 64.9 64.3 70.2 49.6 58.7 58.7 58.8 58.8 63.0 47.2 <br /> 90 67.4 67.4 67.4 67.4 70.1 61.3 61.0 61.0 61.0 61.0 62.7 58.2 <br /> 75 57.8 57.3 66.3 42.6 70.4 26.1 52.3 52.3 59.7 39.7 65.2 24.0 <br /> 2640 80 61.4 61.4 66.2 54.3 70.9 38.6 56.5 56.5 59.4 52.6 63.5 35.6 <br /> 85 65.6 65.6 65.6 65.6 70.9 52.4 59.9 59.9 60.0 60.0 63.4 48.8 <br /> 90 68.5 68.5 68.5 68.5 70.5 65.0 62.1 62.1 62.1 62.1 62.9 61.8 <br /> 75 58.4 58.4 66.9 44.5 71.1 24.9 53.5 53.5 60.2 41.5 66.4 23.5 <br /> 80 62.9 62.9 66.5 58.5 71.5 40.2 57.7 57.7 59.7 55.3 63.9 37.2 <br /> 2880 <br /> 85 66.8 66.8 66.9 66.9 71.4 55.3 60.7 60.7 60.8 60.8 63.8 50.4 <br /> 90 69.3 69.3 69.4 69.4 70.7 68.6 63.0 63.0 63.0 63.0 63.1 63.1 <br /> Notes: <br /> 1. All capacities shown are gross and have not considered indoor fan heat.To obtain NET cooling capacity subtract indoor fan heat.For indoor fan heat formula,refer <br /> to appropriate airflow table notes. <br /> 2. MBh=Total gross capacity <br /> 3. SHC=Sensible heat capacity <br /> 22 RT-PRC098B-EN <br />