Laserfiche WebLink
aMME <br /> Gross Cooling Capacities <br /> Table 6. Gross cooling capacities-7.5 tons <br /> Entering Wet Bulb Temp(°F) Entering Wet Bulb Temp(°F) Entering Wet Bulb Temp(°F) <br /> CFM E�F;B 61 67 73 61 67 73 61 67 73 <br /> MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC <br /> Ambient Temperature 85°F MM Ambient Temperature 91 Ambient Temperature 105°F <br /> 75 84.8 69.0 96.5 54.8 107.4 34.9 79.9 66.5 91.0 52.3 100.5 34.2 74.7 63.8 85.0 49.5 93.2 33.7 <br /> 2400 80 84.4 80.3 96.3 67.2 107.0 51.6 79.5 77.6 90.8 64.6 100.7 49.0 74.3 74.3 84.9 61.9 93.8 46.2 <br /> 85 86.8 86.8 96.0 79.7 107.1 64.4 83.0 83.0 90.6 77.0 100.9 61.8 78.7 78.7 84.7 72.1 94.1 58.9 <br /> 90 95.5 90.7 95.5 90.7 107.0 77.0 88.1 88.1 90.1 88.0 100.8 74.4 83.7 83.7 84.3 84.3 94.0 71.6 <br /> 75 86.9 73.6 98.8 57.7 108.4 40.0 81.8 69.9 92.9 54.7 101.7 37.3 76.3 65.2 86.7 51.9 94.6 34.0 <br /> 2700 80 86.2 86.2 98.5 71.4 108.9 53.9 81.2 81.2 92.8 68.8 102.4 51.3 76.7 76.7 86.6 66.0 95.2 48.6 <br /> 85 90.5 90.5 98.1 83.3 109.1 68.1 86.4 86.4 92.3 81.8 102.6 65.4 81.9 81.9 86.1 78.8 95.4 62.6 <br /> 90 96.0 96.0 97.4 97.2 108.9 82.3 91.8 91.8 91.9 91.9 102.5 79.6 87.0 87.0 87.1 87.1 95.4 76.8 <br /> 75 88.5 75.2 100.6 60.0 110.5 35.1 83.0 74.4 94.6 57.3 102.9 38.0 77.3 71.4 88.2 54.5 95.4 35.2 <br /> 3000 80 88.0 88.0 100.3 75.5 110.5 56.2 83.8 83.8 94.3 72.8 103.8 53.5 79.3 79.3 88.0 70.0 96.5 50.8 <br /> 85 93.7 93.7 99.5 89.5 110.6 71.7 89.4 89.4 93.6 86.7 103.9 69.0 84.7 84.7 87.2 83.6 96.5 66.1 <br /> 90 99.4 99.4 99.5 99.5 110.5 87.4 94.8 94.8 94.9 94.9 103.8 84.2 89.7 89.7 89.8 89.8 96.5 78.3 <br /> 75 89.5 81.0 102.2 62.6 110.8 41.9 84.0 78.1 96.0 59.8 104.0 35.9 78.2 75.1 89.4 56.9 96.2 35.9 <br /> 3300 80 90.6 90.6 101.7 79.5 111.9 58.5 86.3 86.3 95.6 76.8 105.1 55.5 81.5 81.5 89.0 73.0 97.5 51.7 <br /> 85 96.5 96.5 100.6 94.3 111.8 75.3 92.0 92.0 94.4 94.4 104.9 72.6 87.0 87.0 87.9 87.9 97.3 69.6 <br /> 90 102.3 102.3 102.4 102.4 111.7 89.6 97.4 97.4 97.5 97.5 104.6 88.5 92.0 92.0 92.0 92.0 96.8 85.2 <br /> 75 90.5 84.7 103.5 65.0 112.3 39.6 84.8 84.8 97.1 62.3 104.8 36.0 78.8 78.8 90.3 59.3 96.9 36.1 <br /> 80 92.9 92.9 102.9 83.4 113.1 60.3 88.4 88.4 96.6 78.5 105.9 57.5 83.5 83.5 89.6 76.5 98.2 54.5 <br /> 3600 <br /> 85 99.0 99.0 101.3 101.3 112.8 78.8 94.2 94.2 95.1 95.1 105.8 76.0 88.9 88.9 89.0 89.0 98.0 73.1 <br /> 90 104.7 104.7 104.8 104.8 112.2 95.8 99.6 99.6 99.7 99.7 105.0 92.8 93.7 93.7 93.8 93.8 97.0 89.5 <br /> Ambient Temperature 115°F Ambient Temperature 125°F <br /> 75 69.0 59.6 78.5 46.4 86.1 28.2 62.8 57.2 71.6 43.3 77.5 26.3 <br /> 2400 80 69.3 69.3 78.5 59.0 86.3 43.4 64.4 64.4 71.6 55.9 78.1 40.3 <br /> 85 74.1 74.1 78.2 70.7 86.6 55.9 69.0 69.0 71.3 67.4 78.3 52.7 <br /> 90 78.8 78.8 78.9 78.9 86.6 68.6 73.2 73.2 73.3 73.3 78.4 64.8 <br /> 75 70.2 64.4 80.1 49.0 86.9 28.5 63.8 61.1 72.9 45.8 78.1 26.8 <br /> 2700 80 72.0 72.0 80.0 63.0 87.6 45.5 66.8 66.8 72.8 59.9 79.3 42.1 <br /> 85 77.0 77.0 79.5 75.7 87.6 59.5 71.4 71.4 72.2 72.2 79.1 56.2 <br /> 90 81.7 81.7 81.8 81.8 87.7 71.9 75.5 75.5 75.6 75.6 78.9 69.4 <br /> 75 71.2 68.2 81.3 51.5 87.5 28.9 64.6 64.6 73.8 48.2 78.5 27.4 <br /> 3000 80 74.4 74.4 81.1 66.8 88.6 47.4 68.9 68.9 73.5 63.0 79.9 44.1 <br /> 85 79.4 79.4 80.3 80.3 88.4 63.0 73.4 73.4 73.5 73.5 79.6 60.2 <br /> 90 83.9 83.9 84.0 84.0 88.1 77.4 77.1 77.1 77.2 77.2 79.0 73.8 <br /> 75 71.9 71.9 82.3 53.8 87.9 29.3 65.6 65.6 74.6 50.6 79.0 27.5 <br /> 3300 80 76.3 76.3 81.7 69.9 89.3 49.3 70.6 70.6 74.0 66.4 80.3 45.9 <br /> 85 81.4 81.4 81.4 81.4 89.1 66.5 75.0 75.0 75.1 75.1 80.1 63.0 <br /> 90 85.7 85.7 85.8 85.8 88.3 81.8 78.3 78.3 78.3 78.3 79.0 78.1 <br /> 75 72.6 72.6 83.1 56.2 88.5 30.9 67.0 67.0 75.3 52.8 79.4 28.0 <br /> 80 78.1 78.1 82.3 73.2 89.8 51.2 72.0 72.0 74.4 69.7 80.7 47.8 <br /> 3600 <br /> 85 83.0 83.0 83.1 83.1 89.6 69.9 76.3 76.3 76.3 76.3 80.3 65.8 <br /> 90 87.0 87.0 87.1 87.1 88.4 86.0 79.0 79.0 79.0 79.0 79.0 79.0 <br /> Notes: <br /> 1. All capacities shown are gross and have not considered indoor fan heat.To obtain NETcooling capacity subtract indoor fan heat.For indoor fan heat formula,refer <br /> to appropriate airflow table notes. <br /> 2. MBh=Total gross capacity <br /> 3. SHC=Sensible heat capacity <br /> RT-PRC098B-EN 23 <br />