STRUCTURAL INFORMATION: STRUCTURAL NOTES: PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE <br /> ROOF TYPE (1): <br /> ROOF TYPE: Comp Shingle <br /> SHEATHING TYPE: SKIP B L U E RAVEN <br /> FRAMING TYPE: Rafter None <br /> FRAMING SIZE: 2x6 @ 24" OC <br /> CEILING JOIST SIZE: 2x6 @ 16"OC 23" 1403 N. Research Way <br /> MAX � 72" MAX. � LANDSCAPE Orem, UT 84097 <br /> ATTACHMENT: SFM Infinity Flashkit 800.377.4480 <br /> RACKING: Unirac SFM Infinity WWW.BLUERAVENSOLAR.COM <br /> @ 48"OC Portrait/72"OC Landscape PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE CONFIDENTIAL-THE INFORMATION <br /> HEREIN CONTAINED SHALL NOT BE <br /> NUMBER OF ATTACHMENTS: 22 USED FOR THE BENEFIT OF ANYONE <br /> EXCEPT BLUE RAVEN SOLAR NOR <br /> PV MODULE COUNT: 9 Modules SHALL IT BE DISCLOSED IN WHOLE OR <br /> IN PART TO OTHERS OUTSIDE <br /> TOTAL ARRAY AREA: 183.6 ft2(20.4ft2/panel) RECIPIENTS ORGANIZATION,EXCEPT <br /> TOTAL ROOF AREA: 2343 ft2 IN CONNECTION WITH THE SALE AND <br /> USE OF THE RESPECTIVE EQUIPMENT, <br /> ARRAY/ROOF AREA: 7.8% WITHOUT THE WRITTEN PERMISSION <br /> ARRAY WEIGHT: 450 Ibs (50 Ibs/panel) 23 48" MAX. — OF BLUE RAVEN SOLAR LLC. <br /> DISTRIBUTED LOAD: 2.45 Ibs/ft2 MAX. PORTRAIT <br /> POINT LOAD: 20.45 Ibs/attachment 'NOTE:LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY ATTACHMENT SPACING- FRONT VIEW -RACKING ATTACHMENTS TO BE STAGGERED NABCEP <br /> BASED ON FIELD CONDITIONS.MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER ^j <br /> ENGINEER OF RECORD SPECIFICATIONS. SCALE: 3/4" = V-0" CERTIFIED <br /> UNIRAC SFM INFINITY UNIRAC SFM MICRORAIL/SPLICE A PV INSTALLATION <br /> PV MODULE PROFESSIONAL <br /> Scott Gurney <br /> OCELLS O.PEAK DUO BILK ML-G10+ 395 #PV-011719-015866 <br /> PV MODULE B PORTRAIT <br /> _ CONTRACTOR: <br /> ® UNIRAC SFM SLIDER _ BRS FIELD OPS <br /> ROOF STRUCTURE 800-377-4480 <br /> (E) ROOF MODULE- <br /> O FLASHING SHEATHING - � _____ - --- WIDTH <br /> A <br /> U U <br /> (1)5/16" STAINLESS STEEL LAG BOLT B <br /> WITH 2-1/2" MIN. EMBEDMENT LANDSCAPE ZO N <br /> AND FLAT WASHER 2Y2" MIN. EMBED. / 230 N 0 LO <br /> _ MODULE <br /> WIDTH W N M <br /> 0O N 'C N N <br /> MIDDLE/TOP STANDOFF DETAIL ATTACHMENT SPACING- SIDE VIEW Z U) M v Cn N <br /> A SCALE: 3" = V-0" (E) BUILDING STRUCTURE D SCALE: 1/2" = V-0" p .O_ <br /> Lu Q- O W W <br /> OCELLS O.PEAK DUO BLK ML-G10+ 395 Sister upgrade is required for (MP1) on all Sealed For a W ICn Cn <br /> PV MODULE rafters that directly support solar PV and that Existing Roof & c E 0Y cn y <br /> have horizontal spans that exceed 9'-6". Attachment Only W j rJ v <br /> L) 2coIII Qin <br /> UNIRAC SFM TRIMRAIL <br /> FLASHING DRAWING BY: <br /> UNIRAC SFM SLIDER AND A' C4lL PremiumCAD <br /> TRIMRAIL ROOF ATTACHMENT (E) ROOF 11 <br /> SHEATHING PLOT DATE:O� O�Wqg� �, <br /> March 13, 2023 <br /> (1) 5/16" STAINLESS STEEL LAG BOLT L- PROJECT NUMBER: <br /> WITH 2-1/2" MIN. EMBEDMENT 722401 <br /> AND FLAT WASHER 2Y2" MIN. EMBED. <br /> 46056 Q SHEET NAME: <br /> S�oN STRUCTURAL <br /> BOTTOM STANDOFF DETAIL REVISION PAGE NUMBER: <br /> B (E) BUILDING STRUCTURE 3/13/23 <br /> SCALE: 3„ = 1 -0 0 PV4 <br />