Minimum Fixtures IBC(WA) <br /> LEVEL 1 WC-MALE+FEMALE LAVS-MALE+FEMALE DRINKING FOUNTAINS <br /> SPACE OCC AREA LOAD OCCUPANTS First#@ Rest @ TOTAL First it @ Rest @ TOTAL <br /> OFFICE B 1,879 SF 1 per 150 SF 12.53 50 1/25 1/50 0.50 80 1/40 1 180 0.31 <br /> *ASSEMBLY A-3 339 SF 1 per 15 SF 22.60 50 1/25 1/50 0.90 80 1/40 1 180 0.57 Accessory Assembly areas in an office(eg Break,Conference)to be calculated as Assembly for occupant load,but as Office for plumbing calculations <br /> INDUSTRIAL F-1,F-2 42,817 SF 1 per 100 SF 428.17 1/100 4.28 1/100 4.28 <br /> TOTAL 45,035 SF 463.30 5.69 5.16 <br /> LEVEL 2 WC-MALE+FEMALE LAVS-MALE+FEMALE DRINKING FOUNTAINS <br /> SPACE OCC AREA LOAD OCCUPANTS First#@ Rest TOTAL First it 9 Rest@ TOTAL <br /> OFFICE B ,-tu3 SF 1 per 150 SF 9.35 50 1 125 1/50 0.37 80 1/40 1/80 0.23 <br /> INDUSTRIAL F-1,F-2 2 SF 1 per 100 SF 0.00 1/100 0.43 1 1100 0.27 ECEIVED <br /> 'ASSEMBLY A-3 162 SF 1 per 15 SF 10.80 50 1125 1/50 0.43 80 1 140 1 180 0.27 <br /> TOTAL 1,565 SF 20.15 0.81 0.50 <br /> BOTH LEVELS 46,600 SF 483.45 6.49 5.66 <br /> FIXTURES PER SEX: 3.25 2.83 MAR 14 2024 <br /> TOTAL-BOTH LEVELS-PER SEX: ( 4.00 Fixtures/Sex I I Fixtures I Sex I C <br /> WA STATE AMMENDMENTS: Drinking Fountains:1 for first 150,1 per each additional 483 Occ I DFs TOTAL CITY <br /> O F EVE <br /> RET <br /> 11118 IBC: GENDER NEUTRAL FACILITIES ARE NOW ALLOWED:See 2902.2.2 for all parameters Permit Services <br /> 2902.1.1 Fixture calculations.To determine the occupant load of each sex,the total occupant load shall be divided in half.To determine the required number <br /> Calculation: of fixtures,the fixture ratio or ratios for each fixture type shall be applied to the occupant load of each sex in accordance with Table 2902.1.Fractional <br /> numbers resulting from applying the fixture ratios of Table 2902.1 shall be rounded up to the next whole number.For calculations involving multiple <br /> occupancies,such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number. <br /> 2018 IPC: 410.3 Provide high and low drinking fountains.Where drinking fountains are required,not fewer than two drinking fountains shall be provided.One drinking 8 a u fountain shall comply with the requirements for people who use a wheelchair and one drinking fountain shall comply with the requirements for standing persons. <br /> WASHINGTON STATE IBC AMENDMENTS: <br /> Urinals: 2902.1.1.2 Urinals.Where urinals are provided,one water closet less than the number specified may be provided for each urinal installed, <br /> except the number of water closets in such cases shall not be reduced to less than one quarter(25%)of the minimum specified. f f� <br /> For men's facilities serving 26 or mom persons,not less than one urinal shall be provided. U 2 n�/ <br /> Drinking 2902.5.1-Occupant loads over 30 shall have one drinking fountain for the first 150 occupants,then one per each additional 500 occupants. 2U '1 0 <br /> 2902.5.4.2-In all occupancies that require more than two drinking fountains per floor or secured area,bottle �� <br /> filling stations shall be permitted to be substituted for up to 50 percent of the required number of drinking fountains. T Y OF <br /> T <br /> Fountains 2902.5.2 Multistory buildings.Drinking fountains shall be provided on each floor having more than 30 occupants in schools,dormitories,auditoriums,theaters, Permit <br /> offices and public buildings. Permit -Q RE TT <br /> Source: IBC 2018 with WA Amendments-NOT Seattle https://up.codes/viewer/washington/wa-building-code-2018 `S <br /> 2018 Amendments PDF download only:https://sbcc.wa.gov/sites/default/files/2021-02/2018%201BC%201nsert%20Pages%204th%20print.pdf <br /> IPC 2018 https://codes.iccsafe.org/content/IPC2018 <br /> i <br /> P:1201813-BRIDGE DEVELOPMENT PARTNERSI20-Everett1111-Fast Signs/Agencyl111 Plumbing Fixtures Reqd by 2018 IBC 29_ALT RM <br />