Laserfiche WebLink
SHEET NOTES: <br /> 1.Provide expansion loops for all water piping per the manufacturer's instructions. <br /> See Detail 7/P5.0. <br /> 2.Provide trap primers for all floor drains per 2018 UPC 1007.1.See Detail 6/P5.0. <br /> ROOF <br /> 2"CW(41 FU) 3.Install thermostatic mixing valves and set to 100°F in all public lavatories.See 0 z <br /> Detail2/P5.0. a_ o <br /> Y"HW(1.5 FU) Y4"HW(2.25 FU) Y4"HW(3 FU) N <br /> Y"Hwc(1 GPM) of <br /> FLAG NOTES: o <br /> Y2"CW(1.5 FU) Y4 CW(2.25 FU) 2"CW(38 FU) 2"CW(34 FU) 2"CW(30 FU) 2"CW(25 FU) 2"CW(20 FU) 2"CW(15 FU) 1Yz"CW(10 FU) <br /> 1.Contractor to tie into existing CW piping and existing water heater. <br /> T---T---T 0 <br /> ZZ <br /> T a a a s a a �0��J 0\ <br /> � <br /> G <br /> LV-1 Lv-1 LV-1 LV-1 <br /> Y2"HW,Y2"CW Yz"HW,Yz"CW Y"HW,%'CW Y"HW,%'CW <br /> UR-1 UR-1 WC-1 WC-1 WC-1 WC-1 WC-1 WC-1 T <br /> %4"CW %4-CW %i CW Y4"CW Y4"CW Y4"CW Y4"CW Y4"CW FLOOR 1 K Om Q O A <br /> ENGINEERING,INC <br /> w.,5 TE3b2 <br /> ' LVNNWOOD,WA96036 <br /> 2063663343�n <br /> REIPROJE-0.:5-26 <br /> UNDERSLAB <br /> Y Y J <br /> SUPPLY DIAGRAM n o o W <br /> L Z Z Y 0 <br /> 2U 0 <br /> w = a <br /> 0 � U Q <br /> SHEET NOTES: <br /> 1. Waste&Vent Sizing:waste&vent piping sized per 2018 UPC Table 703.2. <br /> ROOF Piping 4"and larger shall be sloped at%"per foot with approval of AHJ. <br /> 1Y2'V(2 FU) 1Y2"V(3 FU) 1Y2"V(4 FU) 3-V(36 FU) Piping smaller than 4"shall be sloped at 4"per foot: <br /> ________________________ ______________________ ___________ ______j 1 <br /> r--- T T T ------ 2N(20 FU) TV(24 FU) 3N(28 FU) <br /> I I I I ------------------ 3"V(32FU) PIPE SIZE VERT. HORIZ. VENT <br /> I I I I 2-V 8Fu TV 12Fu r_______ T_______T_______� <br /> 1. (4 FU) ( ) ( ) 1Yz"V(4 FU) I I I 1%" 2 FU 1 FU 8 FU <br /> II I I _______T_______T_______T_______+_________T_______� <br /> I I I I I I I I I I I 1 I I 2" 16 FU 8 FU 24DFU <br /> I I I I I I I I I I I 3" 48 FU 35 FU 84 FU <br /> LLI LLI LLI LLI LLI LLI LLI LLI LLI 11 1 LLI LLI LLI <br /> =1 =1 =1 =1 �I �I el el el el el el 4" 256FU 172FU 256FU <br /> 6" 1,380 FU 576 FU 1,380 FU LJLJ m <br /> 8" 3,600 FU 2,112 FU 3,600 FU <br /> I I I I I I I I I I I I I I <br /> I I I I I I I I I I I I I I Q NmM <br /> I I I I I I I I I I I I I 2. Provide floor and wall cleanouts as required by code. (� m <br /> LV-1 LV-1 LV-1 LV-1 I I I I I I I I I >Q <br /> 1Y2'v,1Y2"Ss 1Y2'v,1Y2"Ss 1Y2'v,1Y2"Ss 1Y2'v,1Y2"Ss I I I I I I I I I Q =30 <br /> I I I I I I I I I 3. Provide trap primers for all floor drains per 2018 UPC 1007.1.See Detail L11 o o$ <br /> I I I I I I I I I 6/P5.0. ` 3 Z <br /> I I I �Z0 <br /> UR-1 UR-1 WC-1 WC-1 WG1 2"FD-1 2"FD-1 WC-1 WC-1 WC-1 FLAG NOTES: T <br /> 1Y2"V,2-SS 1Y2"V,2-SS 2-V,3"SS 2-V,3"SS 2N,3"SS 1Y2"V,2"SS 1Y2"V,2"SS 2"V,3"SS 2"V,3"SS 2"V,3"SS FLOOR 1 ^ o <br /> 1. Contractor to tie into existing waste&vent piping. v=J 'rn Z <br /> LL LL LL LL � 0� � <br /> 2 ti N � Z <br /> a a a a ti ti ti ti C M <br /> Z LoW W W <br /> 2-SS(4 FU) U O <br /> 4"S$(32 FU) W <br /> 2-SS(4 FU) 3"SS(8 FU) 3"SS(12 FU) 3"SS(16 FU) 4-SS(24 FU) 4"SS(28 FU) d W <br /> 2-SS(2 FU) 2"SS(3 FU) 2"SS(4 FU) 3"SS(20 FU) <br /> O <br /> DATE: 03/19/2024 <br /> 4"SS(36 FU) <br /> SHEET TITLE: <br /> WASTE&SUPPLY <br /> DIAGRAMS <br /> UNDERSLAB <br /> WASTE DIAGRAM HEET NO. <br /> P4.0 <br />