Laserfiche WebLink
SHEET NOTES: <br /> 1.Provide expansion loops for all water piping per the manufacturer's instructions. <br /> See Detail 7/P5.0. <br /> 2.Provide trap primers for all floor drains per 2018 UPC 1007.1.See Detail 6/P5.0. <br /> ROOF <br /> 3.Install thermostatic mixing valves and set to 100°F in all public lavatories.See o z <br /> 3Y4^CW(4 FU) YeCW 6 FU VCW(8 FU) 2"CW(18 FU) 2"CW(28 FU) 2"CW(38 FU) 2"CW(48 FU) �"Cw(58 FU 2Y2"CW(59.5 FU 7Y2"CW(61 FU ZV2T 62.5 FUl a 0 <br /> Detail 2/P5.0. - <br /> - - - - - 1"HW(11 FU) 1Yn"HW 12.5 F� 1 m W <br /> "HW(4 FU) YeHW(6 FU 1"HW(8 FU) 1"HW(9.5 FU) ( ) U > <br /> —— — —— — — — — of <br /> Y„HW� FLAG NOTES: 0 <br /> 1.Contractor to tie into existing CW piping and existing water heater. <br /> a <br /> U 2 U 2 U () <br /> a a Z <br /> 3 3 3 3 3 rI <br /> ZZ <br /> LL LL LL a LL LL LL a LL LL LL a <br /> HS-1 HS-1 HS-1 HS-1 9 S LLI S LLI S LLI m LLI LV-1 LV-1 LV-1 LV-1 LV-1 LV-1 CP <br /> a%"HW 3Ye"CW %"HW, "CW %a'HW,%a'CW %"Hw,%a"CW U V c' U V U U Y"HW,Y2"CW %"HW,Yz"CW Yz"HW,Yz"CW Yz"HW,Yz"CW YZHW,Yz"CW Yz"HW,Yz"CW <br /> WG1 WC-1 WC-1 WC-1 WGi WC-1 WC-1 WC-1 WC-1 WC-1 T <br /> i"Cw %^Cw Yecw %-cw 4"Cw %^Cw %-cw %-cw Y4CW a"Cw FLOOR 1 K O E I S O A <br /> ENGINEERING,INC <br /> ' w.,SU—2 <br /> LVNNWOOD,w 96036 <br /> 200-343- <br /> NEIPNOJEC�N0.:314026 <br /> UNDERSLAB <br /> Y Y J <br /> SUPPLY DIAGRAM n o o W <br /> L z z Y 0 <br /> U U Ir <br /> w S d <br /> SHEET NOTES: <br /> 1. Waste&Vent Sizing:waste&vent piping sized per 2018 UPC Table 703.2. <br /> ROOF Piping 4"and larger shall be sloped at%"per foot with approval of AHJ. <br /> 1Y2"V(4 FU) 1Y2"V(6 FU) 0/2'V(8 FU) TV(16 FU) TV(24 FU) 3W(32 FU) TV(34 FU) TV(42 FU) 3N(44 FU) 3"V(52 FU) YV(54 FU) 3"V(56 FU) TV(58 FU) 1 Piping smaller than 4"shall be sloped at 4"per foot: <br /> r----T----T---- -------------T----------T-----------r ———————————-T- -----------T----7----------T----------T-------- O <br /> I I LLI I LLI I LLI I LLI �I —I �I PIPE SIZE VERT. HORIZ. VENT <br /> 1%" 2FU 1FU 8FU <br /> I I I I I I I I I I I I 2" 16 FU 8FU 24DFU <br /> LLI LLI LLI LLI r----T—J r----T-- r----T—J LLI r----T—J LLI r----T—J I I 3" 48 FU 35 FU 84 FU <br /> I I I a l I I I I ?I I ?I I — --1 F— —� —�—� 4" 256 FU 172 FU 256 FU <br /> �I 'I fl �I I I I I fl I I I LLI LLI LLI LLI LLI LLI 6" 1,380FU 576FU 1,380FU LJj m <br /> > I =1 I� � 8" 3,600 FU 2,112 FU 3,600 FU F <br /> I I I I I I I I I I I I I I I I al �I al �I al �I <br /> I I I I I I I I I I I I I I I I I I I I I I Q Now <br /> I I I I I I I I I I I I I I I 2. Provide floor and wall cleanouts as required by code. (� m <br /> HS-1 HS-1 HS-1 HS-1 I I I I I I LV-1 LV-1 LV-1 LV-1 LV-1 LV-1 ¢3 <br /> 1Yz'v,2^fis 1Y"v,2-SS 1Yz^V,2"SS 1Yzv,2"56 LLI LLI LLI LLI LLI LLI LLI LLI LLI LLI 1Y2'v,1Y2"SS 1Yz"V,1Y2"SS 1Y2"V,1Y2"SS 1Y2"V,1Yz"SS 1Y2'v,1Y2"SS 1Yz"V,1Y2"SS x C)�o <br /> I `Io <br /> 3. Provide trap primers for all floor drains per 2018 UPC 1007.1.See Detail O <br /> o !o <br /> N ` CLL w' 6/P5.0. � <br /> z <br /> ozo <br /> wa1 we-1 wc1 wa1 2FD-1 WC-1 2"FID-1 WC-1 we-1 FLAG NOTES: <br /> TV,3"SS 2N,3SS 2V,3"SS 2"V,YSS 2"V,3"SS 2N,3SS �"V2"SS 2W,YSS TV,3"$S 1YzV,2--SS TV,3"S$ 2"V,YSS FLOORa <br /> 04 <br /> Z z <br /> LL LL LL LL LL LL LL LL LL LL 1. Contractor to tie into existing waste&vent piping. � Q <br /> LL LL LL LL a ,^ <br /> 0 /VMy�l W <br /> Z u3 W W W <br /> LU <br /> LL � LL LL � LL LL O Z <br /> U <br /> ti ti 0 Z <br /> a W <br /> 2-SS(4 FU) 2"SS(6 FU) L 2-SS(8 FU) YSS(16 FU) 4-SS(24 FU) 4"SS(32 FU) 4"SS(34 FU) 4"SS(42 FU) 4-SS(44 FU) 4"SS(52 FU) 4-SS(54 FU) L4-SS(56 FU) 4"SS(58 FU) O <br /> 1 <br /> DATE: 03/19/2024 <br /> SHEET TITLE: <br /> WASTE&SUPPLY <br /> DIAGRAMS <br /> UNDERSLAB <br /> WASTE DIAGRAM HEET NO. <br /> P4.1 <br />