PLUMBING FIXTURES <br /> WC-1 1 112" - 4) 12' - 1.28 GPF WATER CLOSET TBD TBD <br /> WATER SUPPLY SIZING-PEX <br /> MAX VELOCITY,FT/S: 5 HOT/8 COLD 2 HWC LV-1 0.75 0.75 1 1 - 0.5 GPM LAVATORY TBD TBD <br /> MAX PRESSURE DROP,PSI/109: 15.0 <2.5 HSi 1.125 1.125 2 2 - 1.8 GPM SINK TBD TBD <br /> WSFU's GPM FD-1 - - 2 2 - - FLOOR DRAIN NICKLE-BRONZE JR SMITH 2O05Y CAST IRON.PROVIDE TRAP PRIMER TP-1. <br /> PIPE SIZE <br /> FLUSH TANK-HW FLUSH TANK-CW FLUSH VALVE-CW HWC z <br /> NOTES: (1) REFER TO ARCHITECTURAL PLANS FOR MOUNTING HEIGHT. O U <br /> 1/2" 1.8 1.7 0.0 1.1 <br /> (2) FLUSH TRIGGER SHALL BE ON WIDE SIDE OF ROOM. a_ O <br /> 3/4" 6.5 7.9 0.0 2.2 N <br /> 1" 12.1 19.1 0.0 3.6 (3) CONTRACTOR SHALL CONFIRM MAKE,MODEL,AND FINISH OF ALL FIXTURES WITH OWNER PRIOR TO ORDERING. <br /> (4) ALL EXPOSED P-TRAPS SHALL BE CHROME PLATED BRASS. o of <br /> 1-1/4" 19.2 33.5 0.0 5.4 (5) PROVIDE 14 TURN ANGLE STOPS WITH BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT AND COLD WATER SUPPLY TO EACH FIXTURE. <br /> 1-1/2" 28.2 53.3 14.3 7.6 <br /> (6) PROVIDE ASSE-1070 MIXING VALVES SET T0100'F AND METERING FAUCETS AT ALL PUBLIC-USE LAVATORIES. w <br /> 2" 58.7 134.8 52.4 13.0 <br /> 2-112" 122.3 270.6 144.5 19.8 <br /> 3" 227.5 439.0 318.E 28.2 2021 WASHINGTON STATE PIPE INSULATION SCHEDULE <br /> NOTES O <br /> SERVICE MATERIAL THICKNESS VAPOR RETARDER REQUIRED (1)(2)(3)(4) z <br /> DOMESTIC HOT WATER AND RECIRCULATED HOT WATER 2'1�PIPE:1' <br /> (NONRESIDETIAL) MINERAL-FIBER WITH JACKET ig'PIPE:1,1" NO <br /> 2"-PIPE 2" <br /> EXPOSED SANITARYAND STOP FOR ADA FIXTURES. <br /> IS � <br /> WATER SUPPLIES TRUEBRO LAV-GUARD NIA NO P-TRAP AND SUPPLY COVERS \O �vG <br /> NOTES: (1) FOR APPLICABLE CODES REFER TO PLUMBING COVER SHEET. !O\ <br /> (2) PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE.CONTRACTOR SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL.ADHESIVE TAPE SHALL NOT BE G <br /> PERMITTED. <br /> (3) PER 2021 WSEC SECTION R403.5.3(RESIDENTIAL-PERSPECTIVE)INSULATION FOR HOT WATER PIPE SHALL HAVE A MINIMUM R-VALE OF R-3. <br /> (4) PER 2018 UPC,SECTION 312.6 NO WATER,SOIL OR WASTE PIPE SHALL BE INSTALLED OR PERMITTED OUTSIDE OF THE BUILDING,IN ATTIC OR IN AN EXTERIOR WALL UNLESS ADEQUATE PROVISION IS MADE TO PROTECT SUCH PIPE FROM <br /> FREEZING.ALL HOT AND COLD WATER PIPES OUTSIDE THE CONDITIONED SPACE SHALL BE INSULATED TO MINIMUM R-3. <br /> PIPE MATERIALS SCHEDULE <br /> PIPE TYPE MATERIAL JOINT NOTES(1) ROBISON <br /> WATER DISTRIBUTION PIPING PEX EXPANSION OR PRESSED FITTINGS (2)(3) ENGINEERING,INC <br /> WASTE AND VENT PIPING PVC SOLVENT CEMENT (4)(5) i94a� 00D,W 9603602 <br /> 200-343- <br /> C. <br /> NOTES: (1) ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. <br /> (2) PLASTIC WRAP UNDERGROUND SUPPLY PIPING TO PREVENT CORROSION. <br /> (3) PROVIDE THERMAL EXPANSION COMPENSATION FOR ALL PLASTIC PIPING PER MANUFACTURER REQUIREMENTS. <br /> Y Y J <br /> ❑ ❑ <br /> W W > <br /> Z Z <br /> O U � <br /> w = a <br /> ❑ ❑ U Q <br /> G <br /> W <br /> m <br /> F- <br /> U <br /> Qa3ccOn <br /> F Clo <br /> Lu OgN <br /> � <br /> I L z W Z Z <br /> O O <br /> C/) 0 Zz <br /> z <br /> o cc, <br /> /-M- <br /> Z Lo LU W W <br /> LaU O <br /> W <br /> W <br /> DATE: 03/19/2024 <br /> SHEET TITLE: <br /> PLUMBING SCHEDULES <br /> SHEET NO. <br /> P0.1 <br />