My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE BASE FILE 2024-11-13
>
Address Records
>
COLBY AVE
>
1321
>
BASE FILE
>
1321 COLBY AVE BASE FILE 2024-11-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2024 8:32:04 AM
Creation date
11/13/2024 8:20:21 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
K ENGINEERS INC. <br /> 208 Third Street <br /> Lyndon, WA. 98264 W <br /> Bus. (360) 354-4757 .� <br /> FAX (360) 354-6794 <br /> i C/7 <br /> W cl- <br /> Z <br /> rn <br /> TO UNIT SUBSTATION EUS-H4 <br /> fA <br /> �L <br /> 0 i <br /> ma <br /> 2E <br /> CONTINUED ON DRAWING E6.3 <br /> n <br /> TO PARKING GARAGE <br /> LS OR NORMAL/OPT ED TO TOWER FIRE PUMP FIRE PUMP <br /> SA <br /> 3000/3360/3750KVA, <br /> KNAN/KNAN-65/KNAF <br /> 416OV:480Y 277 pM 2727 Oakes Ave. <br /> / wte 100 <br /> 600AS 3D,4W,5.75%Z 800AF ci 1600AF ci 1600A 3200AF ci 800AF 800AF Everett,WA 98201 <br /> 600AF 225AT �i600AT �1200AT�3000AT 300AT 200AT <br /> REVISIONS <br /> y� 5000AF <br /> Q 4500AT <br /> G <br /> EUS-H2 HOSPITAL EMERGENCY POWER <br /> 5000A BUS(LEVEL B-SOUTH) <br /> 4.16kV//480Y/277V 34 4W <br /> 65,000 AIC®480V <br /> SERVICE ENTRANCE RATED <br /> bti R_ DI <br /> 3E2 v1Q'pF WAS <br /> 3 y � <br /> 44794 <br /> �S`FIONAL�yG <br /> n MEDIUM VOLTAGE FEEDER SCHEDULE <br /> TO UNIT SUBSTATION EUS-EH1 TO UNIT SUBSTATION EUS-H1 TO UNIT SUBSTATION EUS-CP1 <br /> FEEDER COPPER CONDUCTORS FEEDER <br /> TYPE AMPACITY <br /> RACEWAY WIRE T <br /> A 6^ #750kcmil 15KV, <br /> #4/OGMV-10 447 cz <br /> 600VXHHW <br /> Fi 3E1 3E2 F ) (NOTE 1) <br /> B 5^ (3)#350kcmil 15KV,MV-105 415 <br /> 133%ERR,(1)#1/OG 600V XHHW ' <br /> C 4^ (3)#4/0 15KV,MV-105 315 X <br /> PROVISION FOR FUTURE PROVISION FOR FUTURE 133%ERR,(1)#1/OG 600V XHHW <br /> 3 3 2E 2 4,� (3)350kcmil 5KV,MV-105 830 <br /> 1000:5 3 Mae Mae 3 1000:5 O 133%EPR,(1)#1/OG,600V XHHW IN EA. <br /> 1000:5 3 13, <br /> ° 3 1000:5 <br /> 3 1000:51000:5 3E1 (3)4^ 3)350kcmil 5KV,MV-105 810 <br /> 1000:5 1000:5 1337.EPR,(1)#2/OG,600V XHHW IN EA. (NOTE 1) <br /> MFP 3MFP 3 MFP MFP 3 MFP 3zz86 z 86 s 1000:5z 1000:5 3E2 (3)4" (3)350kcmil 5KV,MV-105 873 <br /> SPACE NC EMA-1 NC EMA-2 TIE NC EMB-2 NC EMB-1 ^SPACE 1337.EPR,(1)#2/OG,600V XHHW IN EA. NOTE 1 1200AF 52 350AT 52 800AT EMA-EMB52 80OAT 52 500AT 1200AF ( )1200AF 1200AF 1200AF 1200AF 1200AF U52 3 3 F 5^ 500kcmil <br /> GV 60 V XHHW 470 <br /> 1200:5 NO 1200:5 (NOTE 2) <br /> 13,945 13,945 F1 5^ 1 ERR,3) it 5KV, 05 (NOTE81) U m r <br /> 133%ERR,(1)#1/OG,G,6 600V XHHW <br /> 7 <br /> MFP 3 MFP 3 MFP 3 MFP 3 MFP 3 C C4 <br /> NOTE 1: FEEDER AMPACITY BASED ON DUCT BANK STEADY STATE ^+ o <br /> W <br /> THERMAL/AMPACITY ANALYSIS. > 0) <br /> PMVS-CP GEN-1 GEN-2 GEN-3 GEN-4 GEN-FLIT <br /> 52 1200AF 52 1200AF 52 1200AF 52 1200AF 52 1200AF NOTE 2: FEEDER AMPACITY BASED ON ONE CIRCUIT IN DUCT BANK so <br /> PARALLELING MEDIUM VOLTAGE <br /> SWITCHGEAR-CENTRAL PLANT PER NEC TABLE 310.77. <br /> 5 KV,2000A BUS <br /> 4.16KV-30+GND 3 3 3 3 3 O V <br /> 40KA SYM. <br /> L E T ` <br /> CV m <br /> > <br /> F F F F I..L — W <br /> —1 111 <br /> s� s� sA I� sA I� �SAl °9� 22KL <br /> P <br /> TYPICAL GENERATOR Il� eHcarco ar SO <br /> 2000KW 0.8PF 416OV, 1 FUTURE <br /> 30,4W G4 G3 G2 G3 G5 <br /> GENERATOR <br /> #1/0 5kV #1/0 5kv #1/0 5kv #1/0 5kv PERMIT SET <br /> MV-105 CU. MV 400A-105 CU. MV-105 CU, MV-105 CU. , 8-11-24 <br /> Ell IB <br /> 100SEC. 10 SEC. NGR 10 SEC. 100SEC. Y 100SEC. <br /> #1/0 600V #1/0 600V #1/0 600V #1/0 600V <br /> _ XHHW CU. XHHW CU. XHHW CU. XHHW CU. ELECTRICAL - <br /> POWER SYSTEM <br /> RISER DIAGRAM <br /> PARTIAL PRIMARY POWER RISER DIAGRAM - EMERGENCY SYSTEM E 6.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.