Laserfiche WebLink
• <br /> • <br /> ti,i <br /> CO® Worldwide www.tyco-fire.com <br /> Contacts <br /> Model CV-1 F Grooved End <br /> Swing Check Valves <br /> General Never remove any piping component <br /> nor correct or modify any piping defi- I <br /> Descri t/on ciencies without first de-pressurizinga <br /> p and draining the system. Failure to do <br /> The TYCO Model CV-1 F Grooved End so may result in serious personal injury, <br /> Swing Check Valves are compact property damage, and/or impaired .. <br /> device performance. <br /> and rugged swing-type units that <br /> allow water flow in one direction and The owner is responsible for main- <br /> prevent flow in the opposite direction. taining their fire protection system <br /> A resilient elastomer seal facing on the and devices in proper operating con ; <br /> spring-loaded clapper ensures a leak- dition. Contact the installing contrac- <br /> tight seal and non-sticking operation. tor or product manufacturer with any <br /> The Model CV-1F Check Valves are questions. <br /> designed to minimize water hammer caused by flow reversal. ■T echnical <br /> The Model CV-1F Grooved End Swing DataC 111> <br /> Check Valves are furnished with <br /> grooved ends and can be installed APPROVED <br /> using GRINNELL Grooved Couplings Approvals <br /> or GRINNELL Figure 71 Flange Adapt- Compliance with CE Pressure Equipment „, <br /> ers. The Model CV-1F Check Valves Directive(PED)and Standards of VdS , v " <br /> have been designed with a removable Engineering Practice aia <br /> cover for ease of field maintenance. • 2 in. to 12 in. (DN50 to DN300): For fire protection pressure rating, <br /> listing and approval information,contact <br /> These valves can be installed horizon- UL and C-UL Listed, FM Approved, your TYCO representative. <br /> tally(with cover in the upward position) Bureau Veritas <br /> or vertically with the flow in the upward • 2 1/2 in. to 10 in. (DN65 to DN250): <br /> direction,see Figure 3. VdS Approved Certificate No. Installation <br /> A check valve maintenance kit is avail- G4060018 The Model CV-1F Grooved End Swing <br /> able to allow backflushing through a Sizes Check Valves are to be installed in <br /> fire department connection without 2 in.to 12 in.(DN50 to DN300) accordance with this section: <br /> removing the Model CV-1F Grooved <br /> End Swing Check Valve from the riser. Maximum Working Pressure Step 1. The arrow cast on the body <br /> Refer to technical data sheet TFP1555. UL/FM-300 psi(20,7 bar) must point in the direction of the flow. <br /> VdS-16 bar <br /> Model CV-1F is a re-designation for Step 2. Valves installed vertically <br /> Central Figure 590F and GRINNELL Valve Assembly Finish must be positioned with the flow in the <br /> Figure 590F Grooved End Swing Check Red,non-lead paint upward direction. <br /> Valves. Step 3. Valves installed horizontally <br /> NOTICE must be positioned with the cover <br /> facing up,see Figure 3. <br /> The TYCO Model CV-IF Grooved End Step 4. Grooved end pipe couplings <br /> Swing Check Valves described herein used with the Model CV-1 F Grooved <br /> must be installed and maintained in End Swing Check Valves must be <br /> compliance with this document and installed in accordance with manufac- <br /> with the applicable standards of the turer's instructions. <br /> NATIONAL FIRE PROTECTION ASSO- <br /> CIATION (NFPA), in addition to the Note: Valves should be installed a <br /> standards of any authorities having reasonable distance downstream from <br /> jurisdiction.Failure to do so may impair pumps,elbows, expanders,reducers, or <br /> the performance of these devices. other similar devices to extend the valve <br /> life. Standard piping practices call for a <br /> _ minimum of five(5)times the pipe diameter <br /> IMPORTANT for general use. <br /> Refer to Technical Data Sheet <br /> TFP2300 for warnings pertaining to <br /> regulatory and health information. <br /> Page 1 of 6 DECEMBER 2020 TFP1550 <br />