My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
815 SIEVERS-DUECY BLVD 2025-05-05
>
Address Records
>
SIEVERS-DUECY BLVD
>
815
>
815 SIEVERS-DUECY BLVD 2025-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2025 7:46:45 AM
Creation date
11/19/2024 11:57:43 AM
Metadata
Fields
Template:
Address Document
Street Name
SIEVERS-DUECY BLVD
Street Number
815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
960
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. TFP1550 <br /> • Page 2 of 6 <br /> Nominal Dimensions <br /> Nominal Pipe Size In. Cover <br /> (mm) Bolt Approx. <br /> Torque Weight <br /> Valve Size Pipe O.D. lb-ft lb(kg) <br /> In. In. A B C D E F J (N•m) <br /> (DN) (mm) q <br /> 2 2.37 6.75 196 1.96 2.57 3.25 4.75 1.62 7 9.0 <br /> (50) (60.3) (171 5) (49.8) (49.8) (65.3) (82.3) (120.7) (41.5) (10) (4.5) <br /> 21/2 2.88 8.00 5.38 2.63 3.09 3.87 5.87 1.63 10 10.0 <br /> (65) (73.0) (203.2) (136.7) (66.7) (78.5) (98.3) (149.1) (41.7) (14) (4.5) <br /> 76.1 mm 3.00 8.00 5 38 2 63 3.09 3.87 5 87 1.63 10 10.0 <br /> (65) (76.1) (203.2) (136 7) (66.7) (78.5) (98.3) (149.1) (41.7) (14) (4.5) <br /> 3 3.50 8.37 5.72 2.81 3.31 3.87 5.87 1.63 10 11.0 <br /> (80) (88.9) (212.6) (145.3) (71.4) (84.1) (98.3) (149.1) (41.7) (14) (5.0) <br /> 4 4.50 9.63 6.68 3.80 3.63 4.53 7.13 1.84 10 25.0 <br /> (100) (114.3) (244.6) (169.7) (96.5) (92.2) (115 4) (181 1) (46.7) (14) (11.3) <br /> 139.7 mm 5.50 10.50 7.40 4.46 4.13 4.90 7.50 1.75 10 29.0 <br /> (125) (139.7) (266.7) (188.0) (113.3) (104.9) (124.5) (190.5) (44.5) (14) (13.2) <br /> 5 5.56 10.50 7.40 4.46 4.13 4.90 7.50 1.75 10 29.0 <br /> (125) (141.3) (266.7) (188.0) (113.3) (104.9) (124.5) (190.5) (44.5) (14) (13.2) ' <br /> 165.1 mm 6.50 11.50 8.00 4.62 4.50 5.00 7 60 1.85 30 47.0 <br /> (150) (165.1) (292.1) (203 2) (117.3) (114.3) (127.0) (193 0) (47.0) (40) (21.3) <br /> 6 6.63 11.50 8.00 4.62 4.50 5.00 7.60 1.85 30 47.0 <br /> (150) (168.3) (292.1) (203.2) (117.3) (114.3) (127,0) (193,0) (47.0) (40) (21.3) <br /> 8 8.63 14.00 10.14 6 67 5.52 5.46 8 46 2.13 50 66.0 <br /> (200) (219.1) (355.6) (257.8) (169.4) (140.2) (138.7) (214.9) (54.1) (68) (29.9) <br /> 10 10.75 18.00 12.38 8.62 6.41 7.50 10.50 3.00 70 109.7 <br /> (250) (273.1) (457.2) (314.5) (218 9) (162.8) (160.5) (266.7) (76 2) (95) (49.4) <br /> 12 12.75 21.00 14.28 9.93 7.27 7.62 10.62 2.75 80 151.0 <br /> (300) (323.9) (533.4) (362.7) (252.2) (184.7) (193.5) (269 7) (69.9) (108) (68.0) <br /> B . A <br /> e=10% <br /> II <br /> III <br /> I 1 IO ♦ O.o. <br /> ID <br /> Wall a* <br /> 1/2" <br /> NPT <br /> • <br /> 1/2" y 3 f <br /> NPT <br /> E <br /> - F - <br /> FIGURE 1 <br /> MODEL CV-1F GROOVED END SWING CHECK VALVES <br /> NOMINAL DIMENSIONS <br /> Care and system from the proper authorities NATIONAL FIRE PROTECTION ASSO- <br /> and notify all personnel who may be CIATION,such as NFPA 25, in addition <br /> Maintenance affected by this decision. to the standards of any authority having <br /> After placing a fire protection system jurisdiction.Contact the installing con <br /> The TYCO Model CV-1 F Grooved End in service, notify the proper authorities tractor or product manufacturer with <br /> Swing Check Valves must be main- and advise those responsible for moni any questions. Any impairments must <br /> tained and serviced in accordance with tonng proprietary and/or central station be immediately corrected. <br /> this section. alarms. Automatic sprinkler systems are rec- <br /> ommendedBefore closing a fire protection system The owner is responsible for the inspec andmaito to be inspected, tested, <br /> main control valve for maintenance tion, testing, and maintenance of their and maintained by a qualified Inspec <br /> work on the fire protection system fire protection system and devices in tion Service in accordance with local <br /> that it controls, obtain permission to compliance with this document,as well requirements and/or national codes. <br /> shut down the affected fire protection as with the applicable standards of the <br />